{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-4838"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-4838","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Characterization and Evaluation of Performance of a Whole-Body Human Exposure Chamber","abstract":"The purpose of this study was to characterize and evaluate the performance of a whole-body human exposure chamber for controlled test atmospheres of gases and particulates. The chamber was constructed from Plexiglass, has a volume of 75 ft 3, operated at a flowrate of 33.8 CFM, and both the makeup and exhaust air are HEPA filtered. Fly ash dust was generated using a Wright Dust Feeder. An elutriator was used to eliminate particles larger 8 μm aerodynamic diameter from the airstream. A direct reading instrument, the Rupprecht and Patashnick PM-10 TEOM, was used for determination of particle concentration. Particle size distributions were determined by a QCM cascade impactor. Data from gravimetric analysis were used to test for the evenness of dust concentrations in the chamber. CO2 is used as a representative gas and its concentration was measured using the Metrosonics aq-5000. Total dust concentrations as measured by the TEOM, in μg/m 3, at 0.2, 0.4, 0.6 and 1.6 RPMs of the Wright Dust Feeder, were 110 + 2.8, 173 + 8.5, 398 + 20 and 550 + 17, respectively. For these RPMs, particle size distributions were associated with a MMD of 1.27 μm and a GSD of 2.35, a MMD of 1.39 and a GSD of 2.22, a MMD of 1.46 and a GSD of 2.08, a MMD of 1.15 and a GSD of 2.2, respectively. Total dust concentrations as measured by gravimetric analysis, in μg/m3 for the respirable fraction. Dust concentrations measured at different points within the chamber showed uniform distribution with a variability less than 10%. Similarly, the particle size distributions were found to be consistent across the different RPMs settings. Regarding carbon dioxide, its concentration was straightforward and the measured and theoretical maximum concentration levels were in agreement. The performance of this whole-body human exposure chamber has been characterized and evaluated for low levels of particles and gases and now it is a valuable research tool for inhalation challenge studies.","abstract_html":"The purpose of this study was to characterize and evaluate the performance of a whole-body human exposure chamber for controlled test atmospheres of gases and particulates. The chamber was constructed from Plexiglass, has a volume of 75 ft 3, operated at a flowrate of 33.8 CFM, and both the makeup and exhaust air are HEPA filtered. Fly ash dust was generated using a Wright Dust Feeder. An elutriator was used to eliminate particles larger 8 μm aerodynamic diameter from the airstream. A direct reading instrument, the Rupprecht and Patashnick PM-10 TEOM, was used for determination of particle concentration. Particle size distributions were determined by a QCM cascade impactor. Data from gravimetric analysis were used to test for the evenness of dust concentrations in the chamber. CO2 is used as a representative gas and its concentration was measured using the Metrosonics aq-5000. Total dust concentrations as measured by the TEOM, in μg/m 3, at 0.2, 0.4, 0.6 and 1.6 RPMs of the Wright Dust Feeder, were 110 + 2.8, 173 + 8.5, 398 + 20 and 550 + 17, respectively. For these RPMs, particle size distributions were associated with a MMD of 1.27 μm and a GSD of 2.35, a MMD of 1.39 and a GSD of 2.22, a MMD of 1.46 and a GSD of 2.08, a MMD of 1.15 and a GSD of 2.2, respectively. Total dust concentrations as measured by gravimetric analysis, in μg/m3 for the respirable fraction. Dust concentrations measured at different points within the chamber showed uniform distribution with a variability less than 10%. Similarly, the particle size distributions were found to be consistent across the different RPMs settings. Regarding carbon dioxide, its concentration was straightforward and the measured and theoretical maximum concentration levels were in agreement. The performance of this whole-body human exposure chamber has been characterized and evaluated for low levels of particles and gases and now it is a valuable research tool for inhalation challenge studies.","abstract_has_math":false,"creators":["Pieretti, Luis F."],"institution":"University of South Florida","degree_name":null,"degree_level":"Dissertation","degree_discipline":"Environmental and Occupational Health","degree_department":null,"school":null,"contributors":["Yehia Y. Hammad, Sc.D.","Thomas E. Bernard, Ph.D.","Steven P. Mlynarek, Ph.D.","Yangxin Huang, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-06-17T07:00:00Z","date_published":"2010-06-17T07:00:00Z","updated_at":"2026-11-19T08:37:36Z","subjects":["Inhalation Challenge","Generation of Aerosols","Exposure System","Aerosols","Particulates","American Studies","Arts and Humanities"],"languages":["EN-US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/3611","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/3611","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-4838","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yehia Y. Hammad, Sc.D.","Thomas E. Bernard, Ph.D.","Steven P. Mlynarek, Ph.D.","Yangxin Huang, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Pieretti, Luis F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-06-17T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental and Occupational Health"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation","Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Inhalation Challenge","Generation of Aerosols","Exposure System","Aerosols","Particulates","American Studies","Arts and Humanities"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["EN-US"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/3611"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this study was to characterize and evaluate the performance of a whole-body human exposure chamber for controlled test atmospheres of gases and particulates. The chamber was constructed from Plexiglass, has a volume of 75 ft 3, operated at a flowrate of 33.8 CFM, and both the makeup and exhaust air are HEPA filtered. Fly ash dust was generated using a Wright Dust Feeder. An elutriator was used to eliminate particles larger 8 μm aerodynamic diameter from the airstream. A direct reading instrument, the Rupprecht and Patashnick PM-10 TEOM, was used for determination of particle concentration. Particle size distributions were determined by a QCM cascade impactor. Data from gravimetric analysis were used to test for the evenness of dust concentrations in the chamber. CO2 is used as a representative gas and its concentration was measured using the Metrosonics aq-5000. Total dust concentrations as measured by the TEOM, in μg/m 3, at 0.2, 0.4, 0.6 and 1.6 RPMs of the Wright Dust Feeder, were 110 + 2.8, 173 + 8.5, 398 + 20 and 550 + 17, respectively. For these RPMs, particle size distributions were associated with a MMD of 1.27 μm and a GSD of 2.35, a MMD of 1.39 and a GSD of 2.22, a MMD of 1.46 and a GSD of 2.08, a MMD of 1.15 and a GSD of 2.2, respectively. Total dust concentrations as measured by gravimetric analysis, in μg/m3 for the respirable fraction. Dust concentrations measured at different points within the chamber showed uniform distribution with a variability less than 10%. Similarly, the particle size distributions were found to be consistent across the different RPMs settings. Regarding carbon dioxide, its concentration was straightforward and the measured and theoretical maximum concentration levels were in agreement. The performance of this whole-body human exposure chamber has been characterized and evaluated for low levels of particles and gases and now it is a valuable research tool for inhalation challenge studies."]},{"key":"dc:title","label":"Title","values":["Characterization and Evaluation of Performance of a Whole-Body Human Exposure Chamber"]}]}],"canonical_facts":{"dc:contributor":["Yehia Y. Hammad, Sc.D.","Thomas E. Bernard, Ph.D.","Steven P. Mlynarek, Ph.D.","Yangxin Huang, Ph.D."],"dc:creator":["Pieretti, Luis F."],"dc:date":["2010-06-17T07:00:00Z"],"dc:description":["The purpose of this study was to characterize and evaluate the performance of a whole-body human exposure chamber for controlled test atmospheres of gases and particulates. The chamber was constructed from Plexiglass, has a volume of 75 ft 3, operated at a flowrate of 33.8 CFM, and both the makeup and exhaust air are HEPA filtered. Fly ash dust was generated using a Wright Dust Feeder. An elutriator was used to eliminate particles larger 8 μm aerodynamic diameter from the airstream. A direct reading instrument, the Rupprecht and Patashnick PM-10 TEOM, was used for determination of particle concentration. Particle size distributions were determined by a QCM cascade impactor. Data from gravimetric analysis were used to test for the evenness of dust concentrations in the chamber. CO2 is used as a representative gas and its concentration was measured using the Metrosonics aq-5000. Total dust concentrations as measured by the TEOM, in μg/m 3, at 0.2, 0.4, 0.6 and 1.6 RPMs of the Wright Dust Feeder, were 110 + 2.8, 173 + 8.5, 398 + 20 and 550 + 17, respectively. For these RPMs, particle size distributions were associated with a MMD of 1.27 μm and a GSD of 2.35, a MMD of 1.39 and a GSD of 2.22, a MMD of 1.46 and a GSD of 2.08, a MMD of 1.15 and a GSD of 2.2, respectively. Total dust concentrations as measured by gravimetric analysis, in μg/m3 for the respirable fraction. Dust concentrations measured at different points within the chamber showed uniform distribution with a variability less than 10%. Similarly, the particle size distributions were found to be consistent across the different RPMs settings. Regarding carbon dioxide, its concentration was straightforward and the measured and theoretical maximum concentration levels were in agreement. The performance of this whole-body human exposure chamber has been characterized and evaluated for low levels of particles and gases and now it is a valuable research tool for inhalation challenge studies."],"dc:identifier":["https://digitalcommons.usf.edu/etd/3611"],"dc:language":["EN-US"],"dc:rights.license":["default"],"dc:subject":["Inhalation Challenge","Generation of Aerosols","Exposure System","Aerosols","Particulates","American Studies","Arts and Humanities"],"dc:title":["Characterization and Evaluation of Performance of a Whole-Body Human Exposure Chamber"],"thesis:degree_discipline":["Environmental and Occupational Health"],"thesis:degree_level":["Dissertation","Ph.D."],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:37:36Z"}