{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-5092"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-5092","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Palladium Doped Nano Porous Silicon to Enhance Hydrogen Sensing","abstract":"A mass manufacturable impedance based, palladium doped porous silicon sensor, was fabricated for hydrogen detection. The sensor was built using electrochemical etching to produce mesoporous silicon. Four nanometers of palladium was defused directly into the porous silicon and another four nanometers of Pd was deposited on the defused surface to enhance sensing. The sensor was tested in a sealed chamber in which the impedance was measured while hydrogen in nitrogen was ranged from 0-2 percent. Unlike conventional hydrogen sensors this sensor responded at room temperature to changes in hydrogen concentration. The electrical impedance response due to adsorption and desorption of hydrogen reacted relatively quickly due to the nanoparticle nature of palladium diffusion in and Pd evaporation on porous silicon.","abstract_html":"A mass manufacturable impedance based, palladium doped porous silicon sensor, was fabricated for hydrogen detection. The sensor was built using electrochemical etching to produce mesoporous silicon. Four nanometers of palladium was defused directly into the porous silicon and another four nanometers of Pd was deposited on the defused surface to enhance sensing. The sensor was tested in a sealed chamber in which the impedance was measured while hydrogen in nitrogen was ranged from 0-2 percent. Unlike conventional hydrogen sensors this sensor responded at room temperature to changes in hydrogen concentration. The electrical impedance response due to adsorption and desorption of hydrogen reacted relatively quickly due to the nanoparticle nature of palladium diffusion in and Pd evaporation on porous silicon.","abstract_has_math":false,"creators":["Luongo, Kevin"],"institution":"University of South Florida","degree_name":null,"degree_level":"Thesis","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Shekhar Bhansali, Ph.D.","Yogi Goswami, Ph.D.","Sangchae Kim, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-03-24T08:00:00Z","date_published":"2006-03-24T08:00:00Z","updated_at":"2026-11-19T08:37:11Z","subjects":["room temperature","gas sensor","nanoparticle","Labview","palladium diffused","American Studies","Arts and Humanities"],"languages":["EN-US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/3896","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/3896","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-5092","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Shekhar Bhansali, Ph.D.","Yogi Goswami, Ph.D.","Sangchae Kim, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Luongo, Kevin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006-03-24T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.E.E."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["room temperature","gas sensor","nanoparticle","Labview","palladium diffused","American Studies","Arts and Humanities"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["EN-US"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/3896"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A mass manufacturable impedance based, palladium doped porous silicon sensor, was fabricated for hydrogen detection. The sensor was built using electrochemical etching to produce mesoporous silicon. Four nanometers of palladium was defused directly into the porous silicon and another four nanometers of Pd was deposited on the defused surface to enhance sensing. The sensor was tested in a sealed chamber in which the impedance was measured while hydrogen in nitrogen was ranged from 0-2 percent. Unlike conventional hydrogen sensors this sensor responded at room temperature to changes in hydrogen concentration. The electrical impedance response due to adsorption and desorption of hydrogen reacted relatively quickly due to the nanoparticle nature of palladium diffusion in and Pd evaporation on porous silicon."]},{"key":"dc:title","label":"Title","values":["Palladium Doped Nano Porous Silicon to Enhance Hydrogen Sensing"]}]}],"canonical_facts":{"dc:contributor":["Shekhar Bhansali, Ph.D.","Yogi Goswami, Ph.D.","Sangchae Kim, Ph.D."],"dc:creator":["Luongo, Kevin"],"dc:date":["2006-03-24T08:00:00Z"],"dc:description":["A mass manufacturable impedance based, palladium doped porous silicon sensor, was fabricated for hydrogen detection. The sensor was built using electrochemical etching to produce mesoporous silicon. Four nanometers of palladium was defused directly into the porous silicon and another four nanometers of Pd was deposited on the defused surface to enhance sensing. The sensor was tested in a sealed chamber in which the impedance was measured while hydrogen in nitrogen was ranged from 0-2 percent. Unlike conventional hydrogen sensors this sensor responded at room temperature to changes in hydrogen concentration. The electrical impedance response due to adsorption and desorption of hydrogen reacted relatively quickly due to the nanoparticle nature of palladium diffusion in and Pd evaporation on porous silicon."],"dc:identifier":["https://digitalcommons.usf.edu/etd/3896"],"dc:language":["EN-US"],"dc:rights.license":["default"],"dc:subject":["room temperature","gas sensor","nanoparticle","Labview","palladium diffused","American Studies","Arts and Humanities"],"dc:title":["Palladium Doped Nano Porous Silicon to Enhance Hydrogen Sensing"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Thesis","M.S.E.E."],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:37:11Z"}