{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-7803"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-7803","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Corrosion Characteristics of Magnesium under Varying Surface Roughness Conditions","abstract":"The biggest challenge with magnesium alloy biodegradable implants is the rapid corrosion at the earlier stages of the healing process after implantation. In this research, the impact of surface roughness generated by different means on the corrosion rate of AZ31 magnesium alloy in a simulated biologic environment is investigated. In order to perform accurate experimentation, an in vitro setup is assembled that simulates the human body environment accurately has been prepared using Schinhammer’s in vitro immersion testing setup and Kokubo’s Simulated Body Fluid (SBF). For the immersion test of Mg in SBF, several surface texture groups of Mg have been prepared and submerged into the in vitro tank. The Mg samples’ comparative analysis has been made in terms of corrosion rate, total weight loss and hydrogen gas evolution within a span of 7 days for the first experiment to narrow down the scope and 14 days for the follow up experiment. After 14 days of in vitro immersion test with varying roughness and hydrophobic modifications such as Cytop coating and stearic acid modification, it has been observed that the roughness group created by etching in aqueous NaCl solution for three minutes, shows better corrosion resistance compared to the polished control group. Hydrophobic modifications on the surfaces did not affect the corrosion behavior significantly.","abstract_html":"The biggest challenge with magnesium alloy biodegradable implants is the rapid corrosion at the earlier stages of the healing process after implantation. In this research, the impact of surface roughness generated by different means on the corrosion rate of AZ31 magnesium alloy in a simulated biologic environment is investigated. In order to perform accurate experimentation, an in vitro setup is assembled that simulates the human body environment accurately has been prepared using Schinhammer’s in vitro immersion testing setup and Kokubo’s Simulated Body Fluid (SBF). For the immersion test of Mg in SBF, several surface texture groups of Mg have been prepared and submerged into the in vitro tank. The Mg samples’ comparative analysis has been made in terms of corrosion rate, total weight loss and hydrogen gas evolution within a span of 7 days for the first experiment to narrow down the scope and 14 days for the follow up experiment. After 14 days of in vitro immersion test with varying roughness and hydrophobic modifications such as Cytop coating and stearic acid modification, it has been observed that the roughness group created by etching in aqueous NaCl solution for three minutes, shows better corrosion resistance compared to the polished control group. Hydrophobic modifications on the surfaces did not affect the corrosion behavior significantly.","abstract_has_math":false,"creators":["Yayoglu, Yahya Efe"],"institution":"University of South Florida","degree_name":"MS in Mechanical Engineering (M.S.M.E.)","degree_level":"Thesis","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Nathan B. Crane, Ph.D.","Nathan D. Gallant, Ph.D.","Ryan Toomey, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-11-03T07:00:00Z","date_published":"2016-11-03T07:00:00Z","updated_at":"2026-11-19T08:43:17Z","subjects":["etching","medical","sbf","contact angle","Cytop","stearic acid","wetting","hydrophobic","Biomedical Engineering and Bioengineering","Materials Science and Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/6606","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/6606","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-7803","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Nathan B. Crane, Ph.D.","Nathan D. Gallant, Ph.D.","Ryan Toomey, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Yayoglu, Yahya Efe"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-11-03T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.M.E."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Mechanical Engineering (M.S.M.E.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["etching","medical","sbf","contact angle","Cytop","stearic acid","wetting","hydrophobic","Biomedical Engineering and Bioengineering","Materials Science and Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/6606"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The biggest challenge with magnesium alloy biodegradable implants is the rapid corrosion at the earlier stages of the healing process after implantation. In this research, the impact of surface roughness generated by different means on the corrosion rate of AZ31 magnesium alloy in a simulated biologic environment is investigated. In order to perform accurate experimentation, an in vitro setup is assembled that simulates the human body environment accurately has been prepared using Schinhammer’s in vitro immersion testing setup and Kokubo’s Simulated Body Fluid (SBF). For the immersion test of Mg in SBF, several surface texture groups of Mg have been prepared and submerged into the in vitro tank. The Mg samples’ comparative analysis has been made in terms of corrosion rate, total weight loss and hydrogen gas evolution within a span of 7 days for the first experiment to narrow down the scope and 14 days for the follow up experiment. After 14 days of in vitro immersion test with varying roughness and hydrophobic modifications such as Cytop coating and stearic acid modification, it has been observed that the roughness group created by etching in aqueous NaCl solution for three minutes, shows better corrosion resistance compared to the polished control group. Hydrophobic modifications on the surfaces did not affect the corrosion behavior significantly."]},{"key":"dc:title","label":"Title","values":["Corrosion Characteristics of Magnesium under Varying Surface Roughness Conditions"]}]}],"canonical_facts":{"dc:contributor":["Nathan B. Crane, Ph.D.","Nathan D. Gallant, Ph.D.","Ryan Toomey, Ph.D."],"dc:creator":["Yayoglu, Yahya Efe"],"dc:date":["2016-11-03T07:00:00Z"],"dc:description":["The biggest challenge with magnesium alloy biodegradable implants is the rapid corrosion at the earlier stages of the healing process after implantation. In this research, the impact of surface roughness generated by different means on the corrosion rate of AZ31 magnesium alloy in a simulated biologic environment is investigated. In order to perform accurate experimentation, an in vitro setup is assembled that simulates the human body environment accurately has been prepared using Schinhammer’s in vitro immersion testing setup and Kokubo’s Simulated Body Fluid (SBF). For the immersion test of Mg in SBF, several surface texture groups of Mg have been prepared and submerged into the in vitro tank. The Mg samples’ comparative analysis has been made in terms of corrosion rate, total weight loss and hydrogen gas evolution within a span of 7 days for the first experiment to narrow down the scope and 14 days for the follow up experiment. After 14 days of in vitro immersion test with varying roughness and hydrophobic modifications such as Cytop coating and stearic acid modification, it has been observed that the roughness group created by etching in aqueous NaCl solution for three minutes, shows better corrosion resistance compared to the polished control group. Hydrophobic modifications on the surfaces did not affect the corrosion behavior significantly."],"dc:identifier":["https://digitalcommons.usf.edu/etd/6606"],"dc:rights.license":["default"],"dc:subject":["etching","medical","sbf","contact angle","Cytop","stearic acid","wetting","hydrophobic","Biomedical Engineering and Bioengineering","Materials Science and Engineering"],"dc:title":["Corrosion Characteristics of Magnesium under Varying Surface Roughness Conditions"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis","M.S.M.E."],"thesis:degree_name":["MS in Mechanical Engineering (M.S.M.E.)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:43:17Z"}