{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-7819"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-7819","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Sorption of Benzene, Dichloroethane, Chloroform and Dichloromethane by Polyethylene Glycol, Polycaprolactone and Their Copolymers at 298.15 K Using a Quartz Crystal Microbalance","abstract":"Quartz crystal microbalances (QCM) are acoustic wave sensor systems which are used majorly for vapor and liquid sensing. QCM come under the category of thickness shear mode (TSM) sensors. There are several methods to study organic vapor sensing; the QCM method is the one that offers the highest sensitivity and generates the most data. Solubilities of benzene, dichloroethane, chloroform and dichloromethane in polyethylene glycol (PEG), polycaprolactone (PCL), and several di-block PEG/PCL copolymers at 298.15 K are reported. There are literature data available for most of the solvents in the homopolymers PEG and PCL but no literature data is available for the copolymers PEG (5000)/ PCL (1000), PEG (5000)/ PCL (5000) and PEG (1000)/ PCL (5000). Activity vs. weight fraction data was collected using a quartz crystal microbalance and are adequately represented by the Flory-Huggins model within experimental error. The data were reported using a QCM in a newly designed flow system constructed in the lab. The working apparatus consisted of a computer loaded with LabVIEW software for data selection, a quartz crystal cell, four bubblers for solvents, a phase lock oscillator, a frequency counter, and a temperature controlled vapor dilution system. In this thesis, the proof for a working model of the QCM apparatus was reported through a test-case. The test case consists of a study that details the solubility of the polyisobutylene (PIB) polymer in benzene at 298.15 K which was then compared to previous work published in the literature.","abstract_html":"Quartz crystal microbalances (QCM) are acoustic wave sensor systems which are used majorly for vapor and liquid sensing. QCM come under the category of thickness shear mode (TSM) sensors. There are several methods to study organic vapor sensing; the QCM method is the one that offers the highest sensitivity and generates the most data. Solubilities of benzene, dichloroethane, chloroform and dichloromethane in polyethylene glycol (PEG), polycaprolactone (PCL), and several di-block PEG/PCL copolymers at 298.15 K are reported. There are literature data available for most of the solvents in the homopolymers PEG and PCL but no literature data is available for the copolymers PEG (5000)/ PCL (1000), PEG (5000)/ PCL (5000) and PEG (1000)/ PCL (5000). Activity vs. weight fraction data was collected using a quartz crystal microbalance and are adequately represented by the Flory-Huggins model within experimental error. The data were reported using a QCM in a newly designed flow system constructed in the lab. The working apparatus consisted of a computer loaded with LabVIEW software for data selection, a quartz crystal cell, four bubblers for solvents, a phase lock oscillator, a frequency counter, and a temperature controlled vapor dilution system. In this thesis, the proof for a working model of the QCM apparatus was reported through a test-case. The test case consists of a study that details the solubility of the polyisobutylene (PIB) polymer in benzene at 298.15 K which was then compared to previous work published in the literature.","abstract_has_math":false,"creators":["Iyer, Abhijeet Radhakrishna"],"institution":"University of South Florida","degree_name":"MS in Materials Science and Engineering (M.S.M.S.E)","degree_level":"Thesis","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Venkat Bhethanabotla, Ph.D.","Scott Campbell, Ph.D.","John Kuhn, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-03-24T07:00:00Z","date_published":"2017-03-24T07:00:00Z","updated_at":"2026-11-19T08:42:50Z","subjects":["organic vapor sensing","piezoelectric","activity","absorption","adsorption","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/6622","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/6622","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-7819","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Venkat Bhethanabotla, Ph.D.","Scott Campbell, Ph.D.","John Kuhn, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Iyer, Abhijeet Radhakrishna"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-03-24T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.M.S.E."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Materials Science and Engineering (M.S.M.S.E)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["organic vapor sensing","piezoelectric","activity","absorption","adsorption","Chemical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/6622"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Quartz crystal microbalances (QCM) are acoustic wave sensor systems which are used majorly for vapor and liquid sensing. QCM come under the category of thickness shear mode (TSM) sensors. There are several methods to study organic vapor sensing; the QCM method is the one that offers the highest sensitivity and generates the most data. Solubilities of benzene, dichloroethane, chloroform and dichloromethane in polyethylene glycol (PEG), polycaprolactone (PCL), and several di-block PEG/PCL copolymers at 298.15 K are reported. There are literature data available for most of the solvents in the homopolymers PEG and PCL but no literature data is available for the copolymers PEG (5000)/ PCL (1000), PEG (5000)/ PCL (5000) and PEG (1000)/ PCL (5000). Activity vs. weight fraction data was collected using a quartz crystal microbalance and are adequately represented by the Flory-Huggins model within experimental error. The data were reported using a QCM in a newly designed flow system constructed in the lab. The working apparatus consisted of a computer loaded with LabVIEW software for data selection, a quartz crystal cell, four bubblers for solvents, a phase lock oscillator, a frequency counter, and a temperature controlled vapor dilution system. In this thesis, the proof for a working model of the QCM apparatus was reported through a test-case. The test case consists of a study that details the solubility of the polyisobutylene (PIB) polymer in benzene at 298.15 K which was then compared to previous work published in the literature."]},{"key":"dc:title","label":"Title","values":["Sorption of Benzene, Dichloroethane, Chloroform and Dichloromethane by Polyethylene Glycol, Polycaprolactone and Their Copolymers at 298.15 K Using a Quartz Crystal Microbalance"]}]}],"canonical_facts":{"dc:contributor":["Venkat Bhethanabotla, Ph.D.","Scott Campbell, Ph.D.","John Kuhn, Ph.D."],"dc:creator":["Iyer, Abhijeet Radhakrishna"],"dc:date":["2017-03-24T07:00:00Z"],"dc:description":["Quartz crystal microbalances (QCM) are acoustic wave sensor systems which are used majorly for vapor and liquid sensing. QCM come under the category of thickness shear mode (TSM) sensors. There are several methods to study organic vapor sensing; the QCM method is the one that offers the highest sensitivity and generates the most data. Solubilities of benzene, dichloroethane, chloroform and dichloromethane in polyethylene glycol (PEG), polycaprolactone (PCL), and several di-block PEG/PCL copolymers at 298.15 K are reported. There are literature data available for most of the solvents in the homopolymers PEG and PCL but no literature data is available for the copolymers PEG (5000)/ PCL (1000), PEG (5000)/ PCL (5000) and PEG (1000)/ PCL (5000). Activity vs. weight fraction data was collected using a quartz crystal microbalance and are adequately represented by the Flory-Huggins model within experimental error. The data were reported using a QCM in a newly designed flow system constructed in the lab. The working apparatus consisted of a computer loaded with LabVIEW software for data selection, a quartz crystal cell, four bubblers for solvents, a phase lock oscillator, a frequency counter, and a temperature controlled vapor dilution system. In this thesis, the proof for a working model of the QCM apparatus was reported through a test-case. The test case consists of a study that details the solubility of the polyisobutylene (PIB) polymer in benzene at 298.15 K which was then compared to previous work published in the literature."],"dc:identifier":["https://digitalcommons.usf.edu/etd/6622"],"dc:rights.license":["default"],"dc:subject":["organic vapor sensing","piezoelectric","activity","absorption","adsorption","Chemical Engineering"],"dc:title":["Sorption of Benzene, Dichloroethane, Chloroform and Dichloromethane by Polyethylene Glycol, Polycaprolactone and Their Copolymers at 298.15 K Using a Quartz Crystal Microbalance"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Thesis","M.S.M.S.E."],"thesis:degree_name":["MS in Materials Science and Engineering (M.S.M.S.E)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:42:50Z"}