{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-8895"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-8895","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Quantitative Measurement of Cerebral Hemodynamics During Activation of Auditory Cortex With Single- and Multi-Distance Near Infrared Spectroscopy","abstract":"Functional Near Infrared Spectroscopy (fNIRS) is a safe, low-cost, non-invasive opti-cal technique to monitor focal changes in brain activity using neurovascular coupling and measurements of local tissue oxygenation, i.e., changes in concentrations of oxygenated hemoglobin (HbO) and deoxygenated hemoglobin (HbR)[42]. This thesis utilizes two fNIRS approaches to measure hemodynamic changes associated with functional stimulation of the human auditory cortex. The ﬁrst approach, single-distance continuous wave NIRS (CW-NIRS) utilizes relatively simple instrumentation and the Modiﬁed-Beer Lambert (MBL) law to estimate activation induced changes in tissue oxygenation (∆CHbO and ∆CHbR)[17]. The second more complex approach, frequency domain NIRS (FD-NIRS), employs a photon diffusion model of light propagation through tissue to measure both baseline (CHbO and CHbR), and stimulus induced changes in oxygenated and deoxygenated hemoglobin[10]. FD-NIRS is more quantitative, but requires measurements at multiple light source-detector separations and thus its use in measuring focal changes in cerebral hemodynamics have been limited. A commercial FD-NIRS instrument was used to measure the cerebral hemodynamics from the right auditory cortex of 9 adults (21 ± 35 years) with normal hearing, while presented with two types of auditory stimuli: a 1000 Hz Pure tone, and Broad band noise. Measured optical intensities were analyzed using both MBL and photon diﬀusion approaches. Oxygenated hemoglobin was found to increase by 0.351 ± 0.116 µM and 0.060 ± 0.084 µM for Pure tone and Broad band noise stimuli, when analyzed by the MBL method at the ‘best’ source-detector separation. On average (across all sources), MBL analysis estimated an increase in CHbO of 0.100±0.075 µM and 0.099±0.084 µM respectively for Pure tone and Broad band noise stimulation. In contrast, the frequency domain analysis method estimated CHbO to increase by −0.401 ± 0.384 µM and −0.031 ± 0.358 µM for Pure tone and Broad band noise stimulation respectively. These results suggest that although more quantitative, multi-distance FD-NIRS may underestimate focal changes in cerebral hemodynamics that occur due to functional activation. Potential reasons for this discrepancy, including the partial volume eﬀect, are discussed.","abstract_html":"Functional Near Infrared Spectroscopy (fNIRS) is a safe, low-cost, non-invasive opti-cal technique to monitor focal changes in brain activity using neurovascular coupling and measurements of local tissue oxygenation, i.e., changes in concentrations of oxygenated hemoglobin (HbO) and deoxygenated hemoglobin (HbR)[42]. This thesis utilizes two fNIRS approaches to measure hemodynamic changes associated with functional stimulation of the human auditory cortex. The ﬁrst approach, single-distance continuous wave NIRS (CW-NIRS) utilizes relatively simple instrumentation and the Modiﬁed-Beer Lambert (MBL) law to estimate activation induced changes in tissue oxygenation (∆CHbO and ∆CHbR)[17]. The second more complex approach, frequency domain NIRS (FD-NIRS), employs a photon diffusion model of light propagation through tissue to measure both baseline (CHbO and CHbR), and stimulus induced changes in oxygenated and deoxygenated hemoglobin[10]. FD-NIRS is more quantitative, but requires measurements at multiple light source-detector separations and thus its use in measuring focal changes in cerebral hemodynamics have been limited. A commercial FD-NIRS instrument was used to measure the cerebral hemodynamics from the right auditory cortex of 9 adults (21 ± 35 years) with normal hearing, while presented with two types of auditory stimuli: a 1000 Hz Pure tone, and Broad band noise. Measured optical intensities were analyzed using both MBL and photon diﬀusion approaches. Oxygenated hemoglobin was found to increase by 0.351 ± 0.116 µM and 0.060 ± 0.084 µM for Pure tone and Broad band noise stimuli, when analyzed by the MBL method at the ‘best’ source-detector separation. On average (across all sources), MBL analysis estimated an increase in CHbO of 0.100±0.075 µM and 0.099±0.084 µM respectively for Pure tone and Broad band noise stimulation. In contrast, the frequency domain analysis method estimated CHbO to increase by −0.401 ± 0.384 µM and −0.031 ± 0.358 µM for Pure tone and Broad band noise stimulation respectively. These results suggest that although more quantitative, multi-distance FD-NIRS may underestimate focal changes in cerebral hemodynamics that occur due to functional activation. Potential reasons for this discrepancy, including the partial volume eﬀect, are discussed.","abstract_has_math":false,"creators":["Mohammad, Penaz Parveen Sultana"],"institution":"University of South Florida","degree_name":"MS in Electrical Engineering (M.S.E.E.)","degree_level":"Thesis","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Ashwin B. Parthasarathy, Ph.D.","Andrew Hoff, Ph.D.","Ann Eddins, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-06-29T07:00:00Z","date_published":"2018-06-29T07:00:00Z","updated_at":"2026-11-19T08:44:27Z","subjects":["Absolute concentration","fNIRS","Modified Beer-Lambert law","FD-DOS","Functional activation","Electrical and Computer Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/7698","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/7698","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-8895","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ashwin B. Parthasarathy, Ph.D.","Andrew Hoff, Ph.D.","Ann Eddins, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Mohammad, Penaz Parveen Sultana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-06-29T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.E.E."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Electrical Engineering (M.S.E.E.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Absolute concentration","fNIRS","Modified Beer-Lambert law","FD-DOS","Functional activation","Electrical and Computer Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/7698"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Functional Near Infrared Spectroscopy (fNIRS) is a safe, low-cost, non-invasive opti-cal technique to monitor focal changes in brain activity using neurovascular coupling and measurements of local tissue oxygenation, i.e., changes in concentrations of oxygenated hemoglobin (HbO) and deoxygenated hemoglobin (HbR)[42]. This thesis utilizes two fNIRS approaches to measure hemodynamic changes associated with functional stimulation of the human auditory cortex. The ﬁrst approach, single-distance continuous wave NIRS (CW-NIRS) utilizes relatively simple instrumentation and the Modiﬁed-Beer Lambert (MBL) law to estimate activation induced changes in tissue oxygenation (∆CHbO and ∆CHbR)[17]. The second more complex approach, frequency domain NIRS (FD-NIRS), employs a photon diffusion model of light propagation through tissue to measure both baseline (CHbO and CHbR), and stimulus induced changes in oxygenated and deoxygenated hemoglobin[10]. FD-NIRS is more quantitative, but requires measurements at multiple light source-detector separations and thus its use in measuring focal changes in cerebral hemodynamics have been limited. A commercial FD-NIRS instrument was used to measure the cerebral hemodynamics from the right auditory cortex of 9 adults (21 ± 35 years) with normal hearing, while presented with two types of auditory stimuli: a 1000 Hz Pure tone, and Broad band noise. Measured optical intensities were analyzed using both MBL and photon diﬀusion approaches. Oxygenated hemoglobin was found to increase by 0.351 ± 0.116 µM and 0.060 ± 0.084 µM for Pure tone and Broad band noise stimuli, when analyzed by the MBL method at the ‘best’ source-detector separation. On average (across all sources), MBL analysis estimated an increase in CHbO of 0.100±0.075 µM and 0.099±0.084 µM respectively for Pure tone and Broad band noise stimulation. In contrast, the frequency domain analysis method estimated CHbO to increase by −0.401 ± 0.384 µM and −0.031 ± 0.358 µM for Pure tone and Broad band noise stimulation respectively. These results suggest that although more quantitative, multi-distance FD-NIRS may underestimate focal changes in cerebral hemodynamics that occur due to functional activation. Potential reasons for this discrepancy, including the partial volume eﬀect, are discussed."]},{"key":"dc:title","label":"Title","values":["Quantitative Measurement of Cerebral Hemodynamics During Activation of Auditory Cortex With Single- and Multi-Distance Near Infrared Spectroscopy"]}]}],"canonical_facts":{"dc:contributor":["Ashwin B. Parthasarathy, Ph.D.","Andrew Hoff, Ph.D.","Ann Eddins, Ph.D."],"dc:creator":["Mohammad, Penaz Parveen Sultana"],"dc:date":["2018-06-29T07:00:00Z"],"dc:description":["Functional Near Infrared Spectroscopy (fNIRS) is a safe, low-cost, non-invasive opti-cal technique to monitor focal changes in brain activity using neurovascular coupling and measurements of local tissue oxygenation, i.e., changes in concentrations of oxygenated hemoglobin (HbO) and deoxygenated hemoglobin (HbR)[42]. This thesis utilizes two fNIRS approaches to measure hemodynamic changes associated with functional stimulation of the human auditory cortex. The ﬁrst approach, single-distance continuous wave NIRS (CW-NIRS) utilizes relatively simple instrumentation and the Modiﬁed-Beer Lambert (MBL) law to estimate activation induced changes in tissue oxygenation (∆CHbO and ∆CHbR)[17]. The second more complex approach, frequency domain NIRS (FD-NIRS), employs a photon diffusion model of light propagation through tissue to measure both baseline (CHbO and CHbR), and stimulus induced changes in oxygenated and deoxygenated hemoglobin[10]. FD-NIRS is more quantitative, but requires measurements at multiple light source-detector separations and thus its use in measuring focal changes in cerebral hemodynamics have been limited. A commercial FD-NIRS instrument was used to measure the cerebral hemodynamics from the right auditory cortex of 9 adults (21 ± 35 years) with normal hearing, while presented with two types of auditory stimuli: a 1000 Hz Pure tone, and Broad band noise. Measured optical intensities were analyzed using both MBL and photon diﬀusion approaches. Oxygenated hemoglobin was found to increase by 0.351 ± 0.116 µM and 0.060 ± 0.084 µM for Pure tone and Broad band noise stimuli, when analyzed by the MBL method at the ‘best’ source-detector separation. On average (across all sources), MBL analysis estimated an increase in CHbO of 0.100±0.075 µM and 0.099±0.084 µM respectively for Pure tone and Broad band noise stimulation. In contrast, the frequency domain analysis method estimated CHbO to increase by −0.401 ± 0.384 µM and −0.031 ± 0.358 µM for Pure tone and Broad band noise stimulation respectively. These results suggest that although more quantitative, multi-distance FD-NIRS may underestimate focal changes in cerebral hemodynamics that occur due to functional activation. Potential reasons for this discrepancy, including the partial volume eﬀect, are discussed."],"dc:identifier":["https://digitalcommons.usf.edu/etd/7698"],"dc:subject":["Absolute concentration","fNIRS","Modified Beer-Lambert law","FD-DOS","Functional activation","Electrical and Computer Engineering"],"dc:title":["Quantitative Measurement of Cerebral Hemodynamics During Activation of Auditory Cortex With Single- and Multi-Distance Near Infrared Spectroscopy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Thesis","M.S.E.E."],"thesis:degree_name":["MS in Electrical Engineering (M.S.E.E.)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:44:27Z"}