{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-9279"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-9279","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Isokinetic Sampling Efficiency Differences for Blunt Edge vs Sharp Edge Sampling Probes","abstract":"This project aims to determine if sampling efficiency differences are present between a sharp edge probe and a blunt edge probe during isokinetic sampling. To answer this question, isokinetic sampling was performed inside a wind tunnel. Sampling was performed with the sharp edge probe and compared to data previously obtained using the blunt edge probe. Two different particle sizes were used, 0.50 m and 2.00 m, at air velocities of 0.5 m/s, 1.0 m/s and 2.0 m/s in the wind tunnel. Results showed that there is a difference in sampling efficiency between the two probes and a larger difference in the larger particle size. A graph comparing the mass concentrations showed an r value of 0.9990 for the 0.50 m particles and 0.9980 for the 2.00 m particles, meaning the larger particle size has a greater difference than the smaller particles. This can be shown further by looking at the average mass concentration for all wind speeds, where there was a 2.45% increase in the 0.50 m particles and a 14.26% increase in the 2.00 m particles when going from the blunt edge probe to the sharp edge probe. Probe shape should be considered when selecting equipment for isokinetic sampling as a blunt edge probe tends to be less efficient than a sharp edge probe and this difference appears to increase with the particle sizes used.","abstract_html":"This project aims to determine if sampling efficiency differences are present between a sharp edge probe and a blunt edge probe during isokinetic sampling. To answer this question, isokinetic sampling was performed inside a wind tunnel. Sampling was performed with the sharp edge probe and compared to data previously obtained using the blunt edge probe. Two different particle sizes were used, 0.50 m and 2.00 m, at air velocities of 0.5 m/s, 1.0 m/s and 2.0 m/s in the wind tunnel. Results showed that there is a difference in sampling efficiency between the two probes and a larger difference in the larger particle size. A graph comparing the mass concentrations showed an r value of 0.9990 for the 0.50 m particles and 0.9980 for the 2.00 m particles, meaning the larger particle size has a greater difference than the smaller particles. This can be shown further by looking at the average mass concentration for all wind speeds, where there was a 2.45% increase in the 0.50 m particles and a 14.26% increase in the 2.00 m particles when going from the blunt edge probe to the sharp edge probe. Probe shape should be considered when selecting equipment for isokinetic sampling as a blunt edge probe tends to be less efficient than a sharp edge probe and this difference appears to increase with the particle sizes used.","abstract_has_math":false,"creators":["Treloar, Cory A."],"institution":"University of South Florida","degree_name":"MS in Public Health (M.S.P.H.)","degree_level":"Thesis","degree_discipline":"Public Health","degree_department":null,"school":null,"contributors":["Yehia Y. Hammad, Sc.D.","Steven P. Mlynarek, Ph.D.","Jason S. Garica, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-10-30T07:00:00Z","date_published":"2019-10-30T07:00:00Z","updated_at":"2026-11-19T08:51:31Z","subjects":["aerosol collection","aerosol generation","fluorescent polystyrene latex spheres","wind tunnel","Occupational Health and Industrial Hygiene"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/8082","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/8082","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-9279","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yehia Y. Hammad, Sc.D.","Steven P. Mlynarek, Ph.D.","Jason S. Garica, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Treloar, Cory A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-10-30T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Public Health"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.P.H."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Public Health (M.S.P.H.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["aerosol collection","aerosol generation","fluorescent polystyrene latex spheres","wind tunnel","Occupational Health and Industrial Hygiene"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/8082"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This project aims to determine if sampling efficiency differences are present between a sharp edge probe and a blunt edge probe during isokinetic sampling. To answer this question, isokinetic sampling was performed inside a wind tunnel. Sampling was performed with the sharp edge probe and compared to data previously obtained using the blunt edge probe. Two different particle sizes were used, 0.50 m and 2.00 m, at air velocities of 0.5 m/s, 1.0 m/s and 2.0 m/s in the wind tunnel. Results showed that there is a difference in sampling efficiency between the two probes and a larger difference in the larger particle size. A graph comparing the mass concentrations showed an r value of 0.9990 for the 0.50 m particles and 0.9980 for the 2.00 m particles, meaning the larger particle size has a greater difference than the smaller particles. This can be shown further by looking at the average mass concentration for all wind speeds, where there was a 2.45% increase in the 0.50 m particles and a 14.26% increase in the 2.00 m particles when going from the blunt edge probe to the sharp edge probe. Probe shape should be considered when selecting equipment for isokinetic sampling as a blunt edge probe tends to be less efficient than a sharp edge probe and this difference appears to increase with the particle sizes used."]},{"key":"dc:title","label":"Title","values":["Isokinetic Sampling Efficiency Differences for Blunt Edge vs Sharp Edge Sampling Probes"]}]}],"canonical_facts":{"dc:contributor":["Yehia Y. Hammad, Sc.D.","Steven P. Mlynarek, Ph.D.","Jason S. Garica, Ph.D."],"dc:creator":["Treloar, Cory A."],"dc:date":["2019-10-30T07:00:00Z"],"dc:description":["This project aims to determine if sampling efficiency differences are present between a sharp edge probe and a blunt edge probe during isokinetic sampling. To answer this question, isokinetic sampling was performed inside a wind tunnel. Sampling was performed with the sharp edge probe and compared to data previously obtained using the blunt edge probe. Two different particle sizes were used, 0.50 m and 2.00 m, at air velocities of 0.5 m/s, 1.0 m/s and 2.0 m/s in the wind tunnel. Results showed that there is a difference in sampling efficiency between the two probes and a larger difference in the larger particle size. A graph comparing the mass concentrations showed an r value of 0.9990 for the 0.50 m particles and 0.9980 for the 2.00 m particles, meaning the larger particle size has a greater difference than the smaller particles. This can be shown further by looking at the average mass concentration for all wind speeds, where there was a 2.45% increase in the 0.50 m particles and a 14.26% increase in the 2.00 m particles when going from the blunt edge probe to the sharp edge probe. Probe shape should be considered when selecting equipment for isokinetic sampling as a blunt edge probe tends to be less efficient than a sharp edge probe and this difference appears to increase with the particle sizes used."],"dc:identifier":["https://digitalcommons.usf.edu/etd/8082"],"dc:subject":["aerosol collection","aerosol generation","fluorescent polystyrene latex spheres","wind tunnel","Occupational Health and Industrial Hygiene"],"dc:title":["Isokinetic Sampling Efficiency Differences for Blunt Edge vs Sharp Edge Sampling Probes"],"thesis:degree_discipline":["Public Health"],"thesis:degree_level":["Thesis","M.S.P.H."],"thesis:degree_name":["MS in Public Health (M.S.P.H.)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:51:31Z"}