{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-9426"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-9426","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Cancer Biomarker Detection in Human Plasma by Integrating Surface Acoustic Wave and Metal-Enhanced Fluorescence","abstract":"This thesis includes data and discussion about the technique of metal-enhanced fluorescence (MEF) to lower the detection limit of carcinoembryonic antigen (CEA). The detection limit goes down to 100pg/mL level when using MEF substrate made by rapid thermally annealed silver film covered by silica, which has great promise in diagnosing certain types of cancer that uses CEA as detection biomarker, such as pancreatic cancer and colon cancer. To further address the issue of background noises from non-specifically bound proteins (NSB) in complex media, such as plasma, serum, urine and blood, MEF is integrated with surface acoustic wave (SAW) streaming in order to remove these proteins from human plasma while keeping the characteristic of MEF to increase signal to detect target analyte. SAW has also been proven to have the effect of reducing incubation time between antibody and target antigen. Analyzing fluorescence signal shows that the NSB in human plasma can be successfully reduced while the CEA detection limit can be lowered down to 500pg/mL by combining MEF with SAW, allowing for construction of a point of need sensing platform for biomarkers from such complex fluids.","abstract_html":"This thesis includes data and discussion about the technique of metal-enhanced fluorescence (MEF) to lower the detection limit of carcinoembryonic antigen (CEA). The detection limit goes down to 100pg/mL level when using MEF substrate made by rapid thermally annealed silver film covered by silica, which has great promise in diagnosing certain types of cancer that uses CEA as detection biomarker, such as pancreatic cancer and colon cancer. To further address the issue of background noises from non-specifically bound proteins (NSB) in complex media, such as plasma, serum, urine and blood, MEF is integrated with surface acoustic wave (SAW) streaming in order to remove these proteins from human plasma while keeping the characteristic of MEF to increase signal to detect target analyte. SAW has also been proven to have the effect of reducing incubation time between antibody and target antigen. Analyzing fluorescence signal shows that the NSB in human plasma can be successfully reduced while the CEA detection limit can be lowered down to 500pg/mL by combining MEF with SAW, allowing for construction of a point of need sensing platform for biomarkers from such complex fluids.","abstract_has_math":false,"creators":["Huang, Yuqi"],"institution":"University of South Florida","degree_name":"MS in Materials Science and Engineering (M.S.M.S.E)","degree_level":"Thesis","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Venkat Bhethanabotla, Ph.D.","Jason Fleming, M.D.","Ramesh Ayyala, M.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-06-10T07:00:00Z","date_published":"2020-06-10T07:00:00Z","updated_at":"2026-11-19T08:50:23Z","subjects":["CEA","Limit of Detection","Nanoparticles","Rapid Thermal Annealing","Biomedical Engineering and Bioengineering","Electrical and Computer Engineering","Materials Science and Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/8229","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/8229","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-9426","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Venkat Bhethanabotla, Ph.D.","Jason Fleming, M.D.","Ramesh Ayyala, M.D."]},{"key":"dc:creator","label":"Author","values":["Huang, Yuqi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-06-10T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.M.S.E."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Materials Science and Engineering (M.S.M.S.E)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CEA","Limit of Detection","Nanoparticles","Rapid Thermal Annealing","Biomedical Engineering and Bioengineering","Electrical and Computer Engineering","Materials Science and Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/8229"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis includes data and discussion about the technique of metal-enhanced fluorescence (MEF) to lower the detection limit of carcinoembryonic antigen (CEA). The detection limit goes down to 100pg/mL level when using MEF substrate made by rapid thermally annealed silver film covered by silica, which has great promise in diagnosing certain types of cancer that uses CEA as detection biomarker, such as pancreatic cancer and colon cancer. To further address the issue of background noises from non-specifically bound proteins (NSB) in complex media, such as plasma, serum, urine and blood, MEF is integrated with surface acoustic wave (SAW) streaming in order to remove these proteins from human plasma while keeping the characteristic of MEF to increase signal to detect target analyte. SAW has also been proven to have the effect of reducing incubation time between antibody and target antigen. Analyzing fluorescence signal shows that the NSB in human plasma can be successfully reduced while the CEA detection limit can be lowered down to 500pg/mL by combining MEF with SAW, allowing for construction of a point of need sensing platform for biomarkers from such complex fluids."]},{"key":"dc:title","label":"Title","values":["Cancer Biomarker Detection in Human Plasma by Integrating Surface Acoustic Wave and Metal-Enhanced Fluorescence"]}]}],"canonical_facts":{"dc:contributor":["Venkat Bhethanabotla, Ph.D.","Jason Fleming, M.D.","Ramesh Ayyala, M.D."],"dc:creator":["Huang, Yuqi"],"dc:date":["2020-06-10T07:00:00Z"],"dc:description":["This thesis includes data and discussion about the technique of metal-enhanced fluorescence (MEF) to lower the detection limit of carcinoembryonic antigen (CEA). The detection limit goes down to 100pg/mL level when using MEF substrate made by rapid thermally annealed silver film covered by silica, which has great promise in diagnosing certain types of cancer that uses CEA as detection biomarker, such as pancreatic cancer and colon cancer. To further address the issue of background noises from non-specifically bound proteins (NSB) in complex media, such as plasma, serum, urine and blood, MEF is integrated with surface acoustic wave (SAW) streaming in order to remove these proteins from human plasma while keeping the characteristic of MEF to increase signal to detect target analyte. SAW has also been proven to have the effect of reducing incubation time between antibody and target antigen. Analyzing fluorescence signal shows that the NSB in human plasma can be successfully reduced while the CEA detection limit can be lowered down to 500pg/mL by combining MEF with SAW, allowing for construction of a point of need sensing platform for biomarkers from such complex fluids."],"dc:identifier":["https://digitalcommons.usf.edu/etd/8229"],"dc:subject":["CEA","Limit of Detection","Nanoparticles","Rapid Thermal Annealing","Biomedical Engineering and Bioengineering","Electrical and Computer Engineering","Materials Science and Engineering"],"dc:title":["Cancer Biomarker Detection in Human Plasma by Integrating Surface Acoustic Wave and Metal-Enhanced Fluorescence"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Thesis","M.S.M.S.E."],"thesis:degree_name":["MS in Materials Science and Engineering (M.S.M.S.E)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:50:23Z"}