{"id":{"repo_id":"usfca","oai_identifier":"oai:repository.usfca.edu:capstone-3425"},"canonical_url":"https://search.ndltd.org/etd/usfca/oai:repository.usfca.edu:capstone-3425","repository":{"repo_id":"usfca","name":"University of San Francisco","base_url":"https://repository.usfca.edu/do/oai/"},"display":{"title":"Improvements Upon Reprocessing of Orthopedic Single-Use Instruments","abstract":"Internal Medline data for Hospital A, a level I academic trauma center, identified a quality gap due to improper segregation and underutilization of orthopedic single-use device reprocessing bins. The baseline reprocessing rate of 4% for orthopedic products results in missed sustainability opportunities, financial strain, and increased regulated waste. A proposed quality improvement intervention implemented updated communication strategies, visual management tools, and education modules to reinforce current reprocessing workflows and close knowledge gaps. Outcome measures include the percentage of SUDs collected for reprocessing, survey results on reprocessing awareness, and potential financial savings in Appendix I. Early data showed a 10% year-to-year increase in overall SUDs collection, with 54 arthroscopic shavers and 10 orthopedic Class 1 items collected in May following implementation. After June’s data, the reassessment indicated an increase to 38 orthopedic Class 1 items. Although results did not meet the 50% adherence goal, findings suggest that early adaptation changed practice and highlighted opportunities to continue education and refine workflows. Continued evaluation by management and leadership can scale improvement plans to ensure staff compliance, leading to reduced regulated waste and environmental responsibility in patient care.","abstract_html":"Internal Medline data for Hospital A, a level I academic trauma center, identified a quality gap due to improper segregation and underutilization of orthopedic single-use device reprocessing bins. The baseline reprocessing rate of 4% for orthopedic products results in missed sustainability opportunities, financial strain, and increased regulated waste. A proposed quality improvement intervention implemented updated communication strategies, visual management tools, and education modules to reinforce current reprocessing workflows and close knowledge gaps. Outcome measures include the percentage of SUDs collected for reprocessing, survey results on reprocessing awareness, and potential financial savings in Appendix I. Early data showed a 10% year-to-year increase in overall SUDs collection, with 54 arthroscopic shavers and 10 orthopedic Class 1 items collected in May following implementation. After June’s data, the reassessment indicated an increase to 38 orthopedic Class 1 items. Although results did not meet the 50% adherence goal, findings suggest that early adaptation changed practice and highlighted opportunities to continue education and refine workflows. Continued evaluation by management and leadership can scale improvement plans to ensure staff compliance, leading to reduced regulated waste and environmental responsibility in patient care.","abstract_has_math":false,"creators":["Nguyen, Alyssa P"],"institution":null,"degree_name":"Master of Science in Nursing (MSN)","degree_level":"Project/Capstone - Global access","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Cynthia Huff","Silvinia Cuizon"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:39:09Z","subjects":["single-use devices","reprocessing","operating room","sterilization","instruments","recycling","Educational Leadership","Educational Methods","Health Information Technology","Interprofessional Education","Other Education","Other Nursing","Perioperative, Operating Room and Surgical Nursing"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.usfca.edu/capstone/2052","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.usfca.edu/capstone/2052","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.usfca.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.usfca.edu%3Acapstone-3425","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Cynthia Huff","Silvinia Cuizon"]},{"key":"dc:creator","label":"Author","values":["Nguyen, Alyssa P"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-08-10T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-12-15T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Project/Capstone - Global access"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Nursing (MSN)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["single-use devices","reprocessing","operating room","sterilization","instruments","recycling","Educational Leadership","Educational Methods","Health Information Technology","Interprofessional Education","Other Education","Other Nursing","Perioperative, Operating Room and Surgical Nursing"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.usfca.edu/capstone/2052"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Internal Medline data for Hospital A, a level I academic trauma center, identified a quality gap due to improper segregation and underutilization of orthopedic single-use device reprocessing bins. The baseline reprocessing rate of 4% for orthopedic products results in missed sustainability opportunities, financial strain, and increased regulated waste. A proposed quality improvement intervention implemented updated communication strategies, visual management tools, and education modules to reinforce current reprocessing workflows and close knowledge gaps. Outcome measures include the percentage of SUDs collected for reprocessing, survey results on reprocessing awareness, and potential financial savings in Appendix I. Early data showed a 10% year-to-year increase in overall SUDs collection, with 54 arthroscopic shavers and 10 orthopedic Class 1 items collected in May following implementation. After June’s data, the reassessment indicated an increase to 38 orthopedic Class 1 items. Although results did not meet the 50% adherence goal, findings suggest that early adaptation changed practice and highlighted opportunities to continue education and refine workflows. Continued evaluation by management and leadership can scale improvement plans to ensure staff compliance, leading to reduced regulated waste and environmental responsibility in patient care."]},{"key":"dc:title","label":"Title","values":["Improvements Upon Reprocessing of Orthopedic Single-Use Instruments"]}]}],"canonical_facts":{"dc:contributor":["Cynthia Huff","Silvinia Cuizon"],"dc:creator":["Nguyen, Alyssa P"],"dc:date.available":["2026-08-10T07:00:00Z"],"dc:date.created":["2026-12-15T08:00:00Z"],"dc:description.abstract":["Internal Medline data for Hospital A, a level I academic trauma center, identified a quality gap due to improper segregation and underutilization of orthopedic single-use device reprocessing bins. The baseline reprocessing rate of 4% for orthopedic products results in missed sustainability opportunities, financial strain, and increased regulated waste. A proposed quality improvement intervention implemented updated communication strategies, visual management tools, and education modules to reinforce current reprocessing workflows and close knowledge gaps. Outcome measures include the percentage of SUDs collected for reprocessing, survey results on reprocessing awareness, and potential financial savings in Appendix I. Early data showed a 10% year-to-year increase in overall SUDs collection, with 54 arthroscopic shavers and 10 orthopedic Class 1 items collected in May following implementation. After June’s data, the reassessment indicated an increase to 38 orthopedic Class 1 items. Although results did not meet the 50% adherence goal, findings suggest that early adaptation changed practice and highlighted opportunities to continue education and refine workflows. Continued evaluation by management and leadership can scale improvement plans to ensure staff compliance, leading to reduced regulated waste and environmental responsibility in patient care."],"dc:identifier":["https://repository.usfca.edu/capstone/2052"],"dc:subject":["single-use devices","reprocessing","operating room","sterilization","instruments","recycling","Educational Leadership","Educational Methods","Health Information Technology","Interprofessional Education","Other Education","Other Nursing","Perioperative, Operating Room and Surgical Nursing"],"dc:title":["Improvements Upon Reprocessing of Orthopedic Single-Use Instruments"],"thesis:degree_level":["Project/Capstone - Global access"],"thesis:degree_name":["Master of Science in Nursing (MSN)"]},"updated_at":"2026-11-19T08:39:09Z"}