{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-10280"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-10280","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"The History and Dynamics of the Plasma Impedance Probe","abstract":"For over 40 years Utah State University / Space Dynamics Laboratory and their predecessors have built instruments to measure electron density in the ionosphere. These instruments have incrementally improved as new measuring techniques have developed and new technologies have been introduced. This thesis introduces the properties and measurement of electron density in the ionosphere. It maps the instrument advancements from the early radio frequency probes of the 1960's to the present Plasma Impedance Probe (PIP), with emphasis on the introduction of the phase lock looped Plasma Frequency Probe (PFP) and the rediscovery of the Swept Impedance Probe (SIP). The current USU instrument's operation will be detailed. The calibration of the PFP and SIP will be presented, including development of new PIP calibrators. The PFP's loop characteristics and optimization are discussed. Lastly, the current status of the PIP electron density measurement is given, as well as recommended improvements.","abstract_html":"For over 40 years Utah State University / Space Dynamics Laboratory and their predecessors have built instruments to measure electron density in the ionosphere. These instruments have incrementally improved as new measuring techniques have developed and new technologies have been introduced. This thesis introduces the properties and measurement of electron density in the ionosphere. It maps the instrument advancements from the early radio frequency probes of the 1960&#x27;s to the present Plasma Impedance Probe (PIP), with emphasis on the introduction of the phase lock looped Plasma Frequency Probe (PFP) and the rediscovery of the Swept Impedance Probe (SIP). The current USU instrument&#x27;s operation will be detailed. The calibration of the PFP and SIP will be presented, including development of new PIP calibrators. The PFP&#x27;s loop characteristics and optimization are discussed. Lastly, the current status of the PIP electron density measurement is given, as well as recommended improvements.","abstract_has_math":false,"creators":["Sanderson, Wayne G."],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Charles M. Swenson","Wei Ren","Paul D. Israelsen"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:00:26Z","subjects":["electron","ionosphere","Plasma Impedance Probe (PIP)","Plasma Frequency Probe (PFP)","Swept Impedance Probe (SIP)","Electrical and Computer Engineering","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/c847-7346"],"render_values":[{"text":"https://doi.org/10.26076/c847-7346","href":"https://doi.org/10.26076/c847-7346","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/8947","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/8947","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-10280","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Charles M. Swenson","Wei Ren","Paul D. Israelsen"]},{"key":"dc:creator","label":"Author","values":["Sanderson, Wayne G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2007-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["electron","ionosphere","Plasma Impedance Probe (PIP)","Plasma Frequency Probe (PFP)","Swept Impedance Probe (SIP)","Electrical and Computer Engineering","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/8947"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/c847-7346"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["For over 40 years Utah State University / Space Dynamics Laboratory and their predecessors have built instruments to measure electron density in the ionosphere. These instruments have incrementally improved as new measuring techniques have developed and new technologies have been introduced. This thesis introduces the properties and measurement of electron density in the ionosphere. It maps the instrument advancements from the early radio frequency probes of the 1960's to the present Plasma Impedance Probe (PIP), with emphasis on the introduction of the phase lock looped Plasma Frequency Probe (PFP) and the rediscovery of the Swept Impedance Probe (SIP). The current USU instrument's operation will be detailed. The calibration of the PFP and SIP will be presented, including development of new PIP calibrators. The PFP's loop characteristics and optimization are discussed. Lastly, the current status of the PIP electron density measurement is given, as well as recommended improvements."]},{"key":"dc:title","label":"Title","values":["The History and Dynamics of the Plasma Impedance Probe"]}]}],"canonical_facts":{"dc:contributor":["Charles M. Swenson","Wei Ren","Paul D. Israelsen"],"dc:creator":["Sanderson, Wayne G."],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2007-05-01T07:00:00Z"],"dc:description.abstract":["For over 40 years Utah State University / Space Dynamics Laboratory and their predecessors have built instruments to measure electron density in the ionosphere. These instruments have incrementally improved as new measuring techniques have developed and new technologies have been introduced. This thesis introduces the properties and measurement of electron density in the ionosphere. It maps the instrument advancements from the early radio frequency probes of the 1960's to the present Plasma Impedance Probe (PIP), with emphasis on the introduction of the phase lock looped Plasma Frequency Probe (PFP) and the rediscovery of the Swept Impedance Probe (SIP). The current USU instrument's operation will be detailed. The calibration of the PFP and SIP will be presented, including development of new PIP calibrators. The PFP's loop characteristics and optimization are discussed. Lastly, the current status of the PIP electron density measurement is given, as well as recommended improvements."],"dc:identifier":["https://digitalcommons.usu.edu/etd/8947"],"dc:identifier.doi":["https://doi.org/10.26076/c847-7346"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["electron","ionosphere","Plasma Impedance Probe (PIP)","Plasma Frequency Probe (PFP)","Swept Impedance Probe (SIP)","Electrical and Computer Engineering","Engineering"],"dc:title":["The History and Dynamics of the Plasma Impedance Probe"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:00:26Z"}