{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-1112"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-1112","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Predicted Versus Measured Thoracic Gas Volume for the Bod Pod® Air Displacement Plethysmography System","abstract":"The purpose of this study was to determine whether there is a significant difference between measured values of thoracic gas volume (MTGV) and predicted values of thoracic gas volume (PTGV) using the Bod Pod®. One hundred and thirteen college freshmen, both males and females, were tested using the Bod Pod® by first measuring thoracic gas volume with the Bod Pod® technique, then by using pre-determined values based on height, weight, and age that predict thoracic gas volume. Results of a paired t test showed that measured thoracic gas volume and predicted thoracic gas volume were significantly different. A Pearson’s product-moment correlation coefficient was calculated to be r = .60 which is significant at the p ≤ .05 level. A Bland and Altman plot was used to reveal any variability about the mean for individual participants MTGV and PTGV and the averages of each. A Pearson’s product-moment correlation coefficient was calculated for the data in the Bland and Altman plot. The correlation was calculated as .56, which is significant at the p ≤ .001 level. It was concluded that within the limitations of this study, there is a significant difference between MTGV and PTGV when using the Bod Pod® air displacement plethysmography system.","abstract_html":"The purpose of this study was to determine whether there is a significant difference between measured values of thoracic gas volume (MTGV) and predicted values of thoracic gas volume (PTGV) using the Bod Pod®. One hundred and thirteen college freshmen, both males and females, were tested using the Bod Pod® by first measuring thoracic gas volume with the Bod Pod® technique, then by using pre-determined values based on height, weight, and age that predict thoracic gas volume. Results of a paired t test showed that measured thoracic gas volume and predicted thoracic gas volume were significantly different. A Pearson’s product-moment correlation coefficient was calculated to be r = .60 which is significant at the p ≤ .05 level. A Bland and Altman plot was used to reveal any variability about the mean for individual participants MTGV and PTGV and the averages of each. A Pearson’s product-moment correlation coefficient was calculated for the data in the Bland and Altman plot. The correlation was calculated as .56, which is significant at the p ≤ .001 level. It was concluded that within the limitations of this study, there is a significant difference between MTGV and PTGV when using the Bod Pod® air displacement plethysmography system.","abstract_has_math":false,"creators":["Blaney, Phil A"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Kinesiology and Health Science","degree_department":null,"school":null,"contributors":["Edward Heath","Dale R. Wagner","John M. Kras"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:54:59Z","subjects":["Medicine and Health Sciences"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/f85d-37fe"],"render_values":[{"text":"https://doi.org/10.26076/f85d-37fe","href":"https://doi.org/10.26076/f85d-37fe","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/113","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/113","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-1112","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Edward Heath","Dale R. Wagner","John M. Kras"]},{"key":"dc:creator","label":"Author","values":["Blaney, Phil A"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-03-24T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2008-12-01T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Kinesiology and Health Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Medicine and Health Sciences"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/113"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/f85d-37fe"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to determine whether there is a significant difference between measured values of thoracic gas volume (MTGV) and predicted values of thoracic gas volume (PTGV) using the Bod Pod®. One hundred and thirteen college freshmen, both males and females, were tested using the Bod Pod® by first measuring thoracic gas volume with the Bod Pod® technique, then by using pre-determined values based on height, weight, and age that predict thoracic gas volume. Results of a paired t test showed that measured thoracic gas volume and predicted thoracic gas volume were significantly different. A Pearson’s product-moment correlation coefficient was calculated to be r = .60 which is significant at the p ≤ .05 level. A Bland and Altman plot was used to reveal any variability about the mean for individual participants MTGV and PTGV and the averages of each. A Pearson’s product-moment correlation coefficient was calculated for the data in the Bland and Altman plot. The correlation was calculated as .56, which is significant at the p ≤ .001 level. It was concluded that within the limitations of this study, there is a significant difference between MTGV and PTGV when using the Bod Pod® air displacement plethysmography system."]},{"key":"dc:title","label":"Title","values":["Predicted Versus Measured Thoracic Gas Volume for the Bod Pod® Air Displacement Plethysmography System"]}]}],"canonical_facts":{"dc:contributor":["Edward Heath","Dale R. Wagner","John M. Kras"],"dc:creator":["Blaney, Phil A"],"dc:date.available":["2010-03-24T07:00:00Z"],"dc:date.created":["2008-12-01T08:00:00Z"],"dc:description.abstract":["The purpose of this study was to determine whether there is a significant difference between measured values of thoracic gas volume (MTGV) and predicted values of thoracic gas volume (PTGV) using the Bod Pod®. One hundred and thirteen college freshmen, both males and females, were tested using the Bod Pod® by first measuring thoracic gas volume with the Bod Pod® technique, then by using pre-determined values based on height, weight, and age that predict thoracic gas volume. Results of a paired t test showed that measured thoracic gas volume and predicted thoracic gas volume were significantly different. A Pearson’s product-moment correlation coefficient was calculated to be r = .60 which is significant at the p ≤ .05 level. A Bland and Altman plot was used to reveal any variability about the mean for individual participants MTGV and PTGV and the averages of each. A Pearson’s product-moment correlation coefficient was calculated for the data in the Bland and Altman plot. The correlation was calculated as .56, which is significant at the p ≤ .001 level. It was concluded that within the limitations of this study, there is a significant difference between MTGV and PTGV when using the Bod Pod® air displacement plethysmography system."],"dc:identifier":["https://digitalcommons.usu.edu/etd/113"],"dc:identifier.doi":["https://doi.org/10.26076/f85d-37fe"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Medicine and Health Sciences"],"dc:title":["Predicted Versus Measured Thoracic Gas Volume for the Bod Pod® Air Displacement Plethysmography System"],"thesis:degree_discipline":["Kinesiology and Health Science"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:54:59Z"}