{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-1119"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-1119","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"The Influence of Debris Cages on Critical Submergence of Vertical Intakes in Reservoirs","abstract":"This study quantifies the influence of debris cages on critical submergence at vertical intakes in reservoir configurations. Four model debris cages were constructed of light panel material. A vertical intake protruding one pipe diameter above the floor of a model reservoir was tested in six configurations: open intake pipe, a debris grate placed directly over the intake pipe, and debris cages representing widths of 1.5*d and 2*d and heights of 1.5*c and 2*c, where d is diameter of the intake and c is height of intake above reservoir floor. A selection of top grating configurations and a submerged raft configuration were also tested for comparison. Testing of the model debris cages indicates that the roof or top grate of a debris cage dominates the influence a debris cage has on the reduction of critical submergence of air-core vortices. The side grates of a debris cage have some influence on the formation of vortices. The spacing of bars in the top grate has an influence on air-core vortex development. The presence of a debris cage at vertical intakes in still-water reservoirs reduces the critical submergence required to avoid air-core vortices and completely eliminates the air-core vortex for cases where the water surface elevation remains above the top grate of the debris cage. The potential exists for designing debris cages to fulfill a secondary function of air-core vortex suppression.","abstract_html":"This study quantifies the influence of debris cages on critical submergence at vertical intakes in reservoir configurations. Four model debris cages were constructed of light panel material. A vertical intake protruding one pipe diameter above the floor of a model reservoir was tested in six configurations: open intake pipe, a debris grate placed directly over the intake pipe, and debris cages representing widths of 1.5*d and 2*d and heights of 1.5*c and 2*c, where d is diameter of the intake and c is height of intake above reservoir floor. A selection of top grating configurations and a submerged raft configuration were also tested for comparison. Testing of the model debris cages indicates that the roof or top grate of a debris cage dominates the influence a debris cage has on the reduction of critical submergence of air-core vortices. The side grates of a debris cage have some influence on the formation of vortices. The spacing of bars in the top grate has an influence on air-core vortex development. The presence of a debris cage at vertical intakes in still-water reservoirs reduces the critical submergence required to avoid air-core vortices and completely eliminates the air-core vortex for cases where the water surface elevation remains above the top grate of the debris cage. The potential exists for designing debris cages to fulfill a secondary function of air-core vortex suppression.","abstract_has_math":false,"creators":["Allen, Skyler D"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Steven L. Barfuss","Michael C. Johnson","Joseph A. Caliendo"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:57:58Z","subjects":["critical submergence","debris cage","vertical intake","trashracks","vortex","vortices","Civil Engineering","Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/2445-286a"],"render_values":[{"text":"https://doi.org/10.26076/2445-286a","href":"https://doi.org/10.26076/2445-286a","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/120","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/120","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-1119","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Steven L. Barfuss","Michael C. Johnson","Joseph A. Caliendo"]},{"key":"dc:creator","label":"Author","values":["Allen, Skyler D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-03-24T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2008-12-01T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["critical submergence","debris cage","vertical intake","trashracks","vortex","vortices","Civil Engineering","Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/120"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/2445-286a"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study quantifies the influence of debris cages on critical submergence at vertical intakes in reservoir configurations. Four model debris cages were constructed of light panel material. A vertical intake protruding one pipe diameter above the floor of a model reservoir was tested in six configurations: open intake pipe, a debris grate placed directly over the intake pipe, and debris cages representing widths of 1.5*d and 2*d and heights of 1.5*c and 2*c, where d is diameter of the intake and c is height of intake above reservoir floor. A selection of top grating configurations and a submerged raft configuration were also tested for comparison. Testing of the model debris cages indicates that the roof or top grate of a debris cage dominates the influence a debris cage has on the reduction of critical submergence of air-core vortices. The side grates of a debris cage have some influence on the formation of vortices. The spacing of bars in the top grate has an influence on air-core vortex development. The presence of a debris cage at vertical intakes in still-water reservoirs reduces the critical submergence required to avoid air-core vortices and completely eliminates the air-core vortex for cases where the water surface elevation remains above the top grate of the debris cage. The potential exists for designing debris cages to fulfill a secondary function of air-core vortex suppression."]},{"key":"dc:title","label":"Title","values":["The Influence of Debris Cages on Critical Submergence of Vertical Intakes in Reservoirs"]}]}],"canonical_facts":{"dc:contributor":["Steven L. Barfuss","Michael C. Johnson","Joseph A. Caliendo"],"dc:creator":["Allen, Skyler D"],"dc:date.available":["2010-03-24T07:00:00Z"],"dc:date.created":["2008-12-01T08:00:00Z"],"dc:description.abstract":["This study quantifies the influence of debris cages on critical submergence at vertical intakes in reservoir configurations. Four model debris cages were constructed of light panel material. A vertical intake protruding one pipe diameter above the floor of a model reservoir was tested in six configurations: open intake pipe, a debris grate placed directly over the intake pipe, and debris cages representing widths of 1.5*d and 2*d and heights of 1.5*c and 2*c, where d is diameter of the intake and c is height of intake above reservoir floor. A selection of top grating configurations and a submerged raft configuration were also tested for comparison. Testing of the model debris cages indicates that the roof or top grate of a debris cage dominates the influence a debris cage has on the reduction of critical submergence of air-core vortices. The side grates of a debris cage have some influence on the formation of vortices. The spacing of bars in the top grate has an influence on air-core vortex development. The presence of a debris cage at vertical intakes in still-water reservoirs reduces the critical submergence required to avoid air-core vortices and completely eliminates the air-core vortex for cases where the water surface elevation remains above the top grate of the debris cage. The potential exists for designing debris cages to fulfill a secondary function of air-core vortex suppression."],"dc:identifier":["https://digitalcommons.usu.edu/etd/120"],"dc:identifier.doi":["https://doi.org/10.26076/2445-286a"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["critical submergence","debris cage","vertical intake","trashracks","vortex","vortices","Civil Engineering","Environmental Engineering"],"dc:title":["The Influence of Debris Cages on Critical Submergence of Vertical Intakes in Reservoirs"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:57:58Z"}