{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-1266"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-1266","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Calibration and Results of the Equis II Plasma Impedance Probe (PIP)","abstract":"This thesis presents the calibration process and analysis results for the two Plasma Impedance Probe (PIP) units that were ﬂown as part of the NASA Equis-I I campaign from the Kwajalein Atoll. The work of calibration that was presented by Krishna Kurra for the PIP on the Floating Potential Measurement Unit (FPMU) is improved and extended herein. The sweeping impedance probe (SIP), the instrument formerly known as plasma sweeping probe (PSP), is an integral part of the PIP. For the SIP, the calibration presented in this work, calibration error less than 5% error is achieved. The calibration is applied to the ﬂight data to yield impedance measurements. Balmain’s normalized theoretical model is ﬁt to normalized calibrated data to obtain electron density proﬁles within the range of about 2 × 103 to 5 × 106 [Ne /cm3 ]. Electron density proﬁles from the plasma frequency probe (PFP), also part of the PIP, are compared with the density proﬁles from the SIP and there is a close correlation, verifying the calibration and analysis of the SIP.","abstract_html":"This thesis presents the calibration process and analysis results for the two Plasma Impedance Probe (PIP) units that were ﬂown as part of the NASA Equis-I I campaign from the Kwajalein Atoll. The work of calibration that was presented by Krishna Kurra for the PIP on the Floating Potential Measurement Unit (FPMU) is improved and extended herein. The sweeping impedance probe (SIP), the instrument formerly known as plasma sweeping probe (PSP), is an integral part of the PIP. For the SIP, the calibration presented in this work, calibration error less than 5% error is achieved. The calibration is applied to the ﬂight data to yield impedance measurements. Balmain’s normalized theoretical model is ﬁt to normalized calibrated data to obtain electron density proﬁles within the range of about 2 × 103 to 5 × 106 [Ne /cm3 ]. Electron density proﬁles from the plasma frequency probe (PFP), also part of the PIP, are compared with the density proﬁles from the SIP and there is a close correlation, verifying the calibration and analysis of the SIP.","abstract_has_math":false,"creators":["Humphries, Seth D."],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Charles M. Swenson","Randy R. Jost","Michael W. Tompkins"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:54:13Z","subjects":["Equis II","Plasma Impedance Probe","PIP","Electrical and Computer Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/7fc1-0463"],"render_values":[{"text":"https://doi.org/10.26076/7fc1-0463","href":"https://doi.org/10.26076/7fc1-0463","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/271","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/271","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-1266","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Charles M. Swenson","Randy R. Jost","Michael W. Tompkins"]},{"key":"dc:creator","label":"Author","values":["Humphries, Seth D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-03-24T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2005-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Equis II","Plasma Impedance Probe","PIP","Electrical and Computer Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/271"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/7fc1-0463"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the calibration process and analysis results for the two Plasma Impedance Probe (PIP) units that were ﬂown as part of the NASA Equis-I I campaign from the Kwajalein Atoll. The work of calibration that was presented by Krishna Kurra for the PIP on the Floating Potential Measurement Unit (FPMU) is improved and extended herein. The sweeping impedance probe (SIP), the instrument formerly known as plasma sweeping probe (PSP), is an integral part of the PIP. For the SIP, the calibration presented in this work, calibration error less than 5% error is achieved. The calibration is applied to the ﬂight data to yield impedance measurements. Balmain’s normalized theoretical model is ﬁt to normalized calibrated data to obtain electron density proﬁles within the range of about 2 × 103 to 5 × 106 [Ne /cm3 ]. Electron density proﬁles from the plasma frequency probe (PFP), also part of the PIP, are compared with the density proﬁles from the SIP and there is a close correlation, verifying the calibration and analysis of the SIP."]},{"key":"dc:title","label":"Title","values":["Calibration and Results of the Equis II Plasma Impedance Probe (PIP)"]}]}],"canonical_facts":{"dc:contributor":["Charles M. Swenson","Randy R. Jost","Michael W. Tompkins"],"dc:creator":["Humphries, Seth D."],"dc:date.available":["2010-03-24T07:00:00Z"],"dc:date.created":["2005-05-01T07:00:00Z"],"dc:description.abstract":["This thesis presents the calibration process and analysis results for the two Plasma Impedance Probe (PIP) units that were ﬂown as part of the NASA Equis-I I campaign from the Kwajalein Atoll. The work of calibration that was presented by Krishna Kurra for the PIP on the Floating Potential Measurement Unit (FPMU) is improved and extended herein. The sweeping impedance probe (SIP), the instrument formerly known as plasma sweeping probe (PSP), is an integral part of the PIP. For the SIP, the calibration presented in this work, calibration error less than 5% error is achieved. The calibration is applied to the ﬂight data to yield impedance measurements. Balmain’s normalized theoretical model is ﬁt to normalized calibrated data to obtain electron density proﬁles within the range of about 2 × 103 to 5 × 106 [Ne /cm3 ]. Electron density proﬁles from the plasma frequency probe (PFP), also part of the PIP, are compared with the density proﬁles from the SIP and there is a close correlation, verifying the calibration and analysis of the SIP."],"dc:identifier":["https://digitalcommons.usu.edu/etd/271"],"dc:identifier.doi":["https://doi.org/10.26076/7fc1-0463"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Equis II","Plasma Impedance Probe","PIP","Electrical and Computer Engineering"],"dc:title":["Calibration and Results of the Equis II Plasma Impedance Probe (PIP)"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:54:13Z"}