{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-1985"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-1985","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Coanda-Assisted Spray Manipulation Implementation to Plasma Spray","abstract":"Co and a-assisted Spray Manipulation (CSM) is a means of modifying the direction of a jet. Previous isothermal static vectoring research is expanded to plasma spray. Two- dimensional Particle Image Velocimetry (PIV) was used to determine the vectoring results for small angles between 5-10°. Suitable parameters were determined for use on a plasma spray gun for small angle vectoring. Three-dimensional PIV was used to determine the elect of high speed rotation on a vectored jet. A 2-piece CSM collar was retrofitted to a Praxair SG-100 plasma spray gun that replaced the standard faceplate. Two separate collars were tested: one designed for small vector angles and one for larger vector angles. The small-angle device could modify the trajectory of zirconia powder up to several degrees. Doing so could realign the plasma with the powder, resulting in increased powder temperature and velocity. The large-angle device could vector the plasma jet up to 45°; however the powder did not vector as much. Under large-angle vectoring, the powder velocity and temperature decreased steadily with vector angle. Both devices were tested using a supersonic configuration.","abstract_html":"Co and a-assisted Spray Manipulation (CSM) is a means of modifying the direction of a jet. Previous isothermal static vectoring research is expanded to plasma spray. Two- dimensional Particle Image Velocimetry (PIV) was used to determine the vectoring results for small angles between 5-10°. Suitable parameters were determined for use on a plasma spray gun for small angle vectoring. Three-dimensional PIV was used to determine the elect of high speed rotation on a vectored jet. A 2-piece CSM collar was retrofitted to a Praxair SG-100 plasma spray gun that replaced the standard faceplate. Two separate collars were tested: one designed for small vector angles and one for larger vector angles. The small-angle device could modify the trajectory of zirconia powder up to several degrees. Doing so could realign the plasma with the powder, resulting in increased powder temperature and velocity. The large-angle device could vector the plasma jet up to 45°; however the powder did not vector as much. Under large-angle vectoring, the powder velocity and temperature decreased steadily with vector angle. Both devices were tested using a supersonic configuration.","abstract_has_math":false,"creators":["Mabey, Katie E."],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Barton Smith","Robert Spall","Christine Hailey"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:53:19Z","subjects":["Coanda Effect","Plasma Spray","Spray Steering","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/ca09-b4bd"],"render_values":[{"text":"https://doi.org/10.26076/ca09-b4bd","href":"https://doi.org/10.26076/ca09-b4bd","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/997","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/997","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-1985","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Barton Smith","Robert Spall","Christine Hailey"]},{"key":"dc:creator","label":"Author","values":["Mabey, Katie E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2011-08-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Coanda Effect","Plasma Spray","Spray Steering","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/997"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/ca09-b4bd"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Co and a-assisted Spray Manipulation (CSM) is a means of modifying the direction of a jet. Previous isothermal static vectoring research is expanded to plasma spray. Two- dimensional Particle Image Velocimetry (PIV) was used to determine the vectoring results for small angles between 5-10°. Suitable parameters were determined for use on a plasma spray gun for small angle vectoring. Three-dimensional PIV was used to determine the elect of high speed rotation on a vectored jet. A 2-piece CSM collar was retrofitted to a Praxair SG-100 plasma spray gun that replaced the standard faceplate. Two separate collars were tested: one designed for small vector angles and one for larger vector angles. The small-angle device could modify the trajectory of zirconia powder up to several degrees. Doing so could realign the plasma with the powder, resulting in increased powder temperature and velocity. The large-angle device could vector the plasma jet up to 45°; however the powder did not vector as much. Under large-angle vectoring, the powder velocity and temperature decreased steadily with vector angle. Both devices were tested using a supersonic configuration."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>This work made publicly available electronically on August 9, 2011.</p>"]},{"key":"dc:title","label":"Title","values":["Coanda-Assisted Spray Manipulation Implementation to Plasma Spray"]}]}],"canonical_facts":{"dc:contributor":["Barton Smith","Robert Spall","Christine Hailey"],"dc:creator":["Mabey, Katie E."],"dc:date.available":["2011-08-09T07:00:00Z"],"dc:date.created":["2011-05-01T07:00:00Z"],"dc:description.abstract":["Co and a-assisted Spray Manipulation (CSM) is a means of modifying the direction of a jet. Previous isothermal static vectoring research is expanded to plasma spray. Two- dimensional Particle Image Velocimetry (PIV) was used to determine the vectoring results for small angles between 5-10°. Suitable parameters were determined for use on a plasma spray gun for small angle vectoring. Three-dimensional PIV was used to determine the elect of high speed rotation on a vectored jet. A 2-piece CSM collar was retrofitted to a Praxair SG-100 plasma spray gun that replaced the standard faceplate. Two separate collars were tested: one designed for small vector angles and one for larger vector angles. The small-angle device could modify the trajectory of zirconia powder up to several degrees. Doing so could realign the plasma with the powder, resulting in increased powder temperature and velocity. The large-angle device could vector the plasma jet up to 45°; however the powder did not vector as much. Under large-angle vectoring, the powder velocity and temperature decreased steadily with vector angle. Both devices were tested using a supersonic configuration."],"dc:description.note":["<p>This work made publicly available electronically on August 9, 2011.</p>"],"dc:identifier":["https://digitalcommons.usu.edu/etd/997"],"dc:identifier.doi":["https://doi.org/10.26076/ca09-b4bd"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Coanda Effect","Plasma Spray","Spray Steering","Mechanical Engineering"],"dc:title":["Coanda-Assisted Spray Manipulation Implementation to Plasma Spray"],"thesis:degree_discipline":["Mechanical and Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:53:19Z"}