{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-1999"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-1999","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Discharge Coefficients of Oblique Weirs","abstract":"Oblique weirs are those weirs placed at an angle with respect to the channel centerline. They can be used in canal applications where more discharge is needed, but there is limited freeboard. The discharge coefficients were determined for 54 different weirs by measuring total head for various flows over each weir. These weirs included sharp, half round and quarter-round-crested weirs. There were 18 weirs for each crest shape with three weir heights for each angle tested. The oblique angles tested were 10°, 15°, 25°, 45°, 60°, and 90° with respect to the channel centerline, with the nominal weir heights being 4, 8, and 12 inches. The half-round-crested weirs were the most efficient, followed by the quarter-round-crested weirs and the sharp-crested weirs were the least efficient. By decreasing the oblique angle, the weir length became longer and the weir would be more efficient than the normal weir.","abstract_html":"Oblique weirs are those weirs placed at an angle with respect to the channel centerline. They can be used in canal applications where more discharge is needed, but there is limited freeboard. The discharge coefficients were determined for 54 different weirs by measuring total head for various flows over each weir. These weirs included sharp, half round and quarter-round-crested weirs. There were 18 weirs for each crest shape with three weir heights for each angle tested. The oblique angles tested were 10°, 15°, 25°, 45°, 60°, and 90° with respect to the channel centerline, with the nominal weir heights being 4, 8, and 12 inches. The half-round-crested weirs were the most efficient, followed by the quarter-round-crested weirs and the sharp-crested weirs were the least efficient. By decreasing the oblique angle, the weir length became longer and the weir would be more efficient than the normal weir.","abstract_has_math":false,"creators":["Tingey, Samuel Egnew"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Barton Smith","Blake P. Tullis","Robert E. Spall"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:46:41Z","subjects":["Discharge Coefficients","Oblique Weirs","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/0f64-a1c9"],"render_values":[{"text":"https://doi.org/10.26076/0f64-a1c9","href":"https://doi.org/10.26076/0f64-a1c9","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/1010","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/1010","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-1999","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Barton Smith","Blake P. Tullis","Robert E. Spall"]},{"key":"dc:creator","label":"Author","values":["Tingey, Samuel Egnew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2011-09-01T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-08-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Discharge Coefficients","Oblique Weirs","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/1010"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/0f64-a1c9"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Oblique weirs are those weirs placed at an angle with respect to the channel centerline. They can be used in canal applications where more discharge is needed, but there is limited freeboard. The discharge coefficients were determined for 54 different weirs by measuring total head for various flows over each weir. These weirs included sharp, half round and quarter-round-crested weirs. There were 18 weirs for each crest shape with three weir heights for each angle tested. The oblique angles tested were 10°, 15°, 25°, 45°, 60°, and 90° with respect to the channel centerline, with the nominal weir heights being 4, 8, and 12 inches. The half-round-crested weirs were the most efficient, followed by the quarter-round-crested weirs and the sharp-crested weirs were the least efficient. By decreasing the oblique angle, the weir length became longer and the weir would be more efficient than the normal weir."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>This work made publicly available electronically on September 1, 2011.</p>"]},{"key":"dc:title","label":"Title","values":["Discharge Coefficients of Oblique Weirs"]}]}],"canonical_facts":{"dc:contributor":["Barton Smith","Blake P. Tullis","Robert E. Spall"],"dc:creator":["Tingey, Samuel Egnew"],"dc:date.available":["2011-09-01T07:00:00Z"],"dc:date.created":["2011-08-01T07:00:00Z"],"dc:description.abstract":["Oblique weirs are those weirs placed at an angle with respect to the channel centerline. They can be used in canal applications where more discharge is needed, but there is limited freeboard. The discharge coefficients were determined for 54 different weirs by measuring total head for various flows over each weir. These weirs included sharp, half round and quarter-round-crested weirs. There were 18 weirs for each crest shape with three weir heights for each angle tested. The oblique angles tested were 10°, 15°, 25°, 45°, 60°, and 90° with respect to the channel centerline, with the nominal weir heights being 4, 8, and 12 inches. The half-round-crested weirs were the most efficient, followed by the quarter-round-crested weirs and the sharp-crested weirs were the least efficient. By decreasing the oblique angle, the weir length became longer and the weir would be more efficient than the normal weir."],"dc:description.note":["<p>This work made publicly available electronically on September 1, 2011.</p>"],"dc:identifier":["https://digitalcommons.usu.edu/etd/1010"],"dc:identifier.doi":["https://doi.org/10.26076/0f64-a1c9"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Discharge Coefficients","Oblique Weirs","Mechanical Engineering"],"dc:title":["Discharge Coefficients of Oblique Weirs"],"thesis:degree_discipline":["Mechanical and Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:46:41Z"}