{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-2421"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-2421","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Autocorrelation-Based Estimate of Particle Image Density in Particle Image Velocimetry","abstract":"In Particle Image Velocimetry (PIV), the number of particle images per interrogation region, or particle image density, impacts the strength of the correlation and, as a result, the number of valid vectors and the measurement uncertainty. Therefore, any a-priori estimate of the accuracy and uncertainty of PIV requires knowledge of the particle image density. An autocorrelation-based method for estimating the local, instantaneous, particle image density is presented. Synthetic images were used to develop an empirical relationship based on how the autocorrelation peak magnitude varies with particle image density, particle image diameter, illumination intensity, interrogation region size, and background noise. This relationship was then tested using images from two experimental setups with different seeding densities and flow media. The experimental results were compared to image densities obtained through using a local maximum method as well as manual particle counts and are found to be robust. The effect of varying particle image intensities was also investigated and is found to affect the particle image density.","abstract_html":"In Particle Image Velocimetry (PIV), the number of particle images per interrogation region, or particle image density, impacts the strength of the correlation and, as a result, the number of valid vectors and the measurement uncertainty. Therefore, any a-priori estimate of the accuracy and uncertainty of PIV requires knowledge of the particle image density. An autocorrelation-based method for estimating the local, instantaneous, particle image density is presented. Synthetic images were used to develop an empirical relationship based on how the autocorrelation peak magnitude varies with particle image density, particle image diameter, illumination intensity, interrogation region size, and background noise. This relationship was then tested using images from two experimental setups with different seeding densities and flow media. The experimental results were compared to image densities obtained through using a local maximum method as well as manual particle counts and are found to be robust. The effect of varying particle image intensities was also investigated and is found to affect the particle image density.","abstract_has_math":false,"creators":["Warner, Scott O."],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Barton L. Smith","Heng Ban","Robert E. Spall"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:47:02Z","subjects":["autocorrelation","particle image density","particle image velocimetry","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/2d60-f804"],"render_values":[{"text":"https://doi.org/10.26076/2d60-f804","href":"https://doi.org/10.26076/2d60-f804","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/1386","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/1386","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-2421","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Barton L. Smith","Heng Ban","Robert E. Spall"]},{"key":"dc:creator","label":"Author","values":["Warner, Scott O."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2012-12-21T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2012-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["autocorrelation","particle image density","particle image velocimetry","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/1386"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/2d60-f804"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In Particle Image Velocimetry (PIV), the number of particle images per interrogation region, or particle image density, impacts the strength of the correlation and, as a result, the number of valid vectors and the measurement uncertainty. Therefore, any a-priori estimate of the accuracy and uncertainty of PIV requires knowledge of the particle image density. An autocorrelation-based method for estimating the local, instantaneous, particle image density is presented. Synthetic images were used to develop an empirical relationship based on how the autocorrelation peak magnitude varies with particle image density, particle image diameter, illumination intensity, interrogation region size, and background noise. This relationship was then tested using images from two experimental setups with different seeding densities and flow media. The experimental results were compared to image densities obtained through using a local maximum method as well as manual particle counts and are found to be robust. The effect of varying particle image intensities was also investigated and is found to affect the particle image density."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>This work made publicly available electronically on December 21, 2012.</p>"]},{"key":"dc:title","label":"Title","values":["Autocorrelation-Based Estimate of Particle Image Density in Particle Image Velocimetry"]}]}],"canonical_facts":{"dc:contributor":["Barton L. Smith","Heng Ban","Robert E. Spall"],"dc:creator":["Warner, Scott O."],"dc:date.available":["2012-12-21T08:00:00Z"],"dc:date.created":["2012-05-01T07:00:00Z"],"dc:description.abstract":["In Particle Image Velocimetry (PIV), the number of particle images per interrogation region, or particle image density, impacts the strength of the correlation and, as a result, the number of valid vectors and the measurement uncertainty. Therefore, any a-priori estimate of the accuracy and uncertainty of PIV requires knowledge of the particle image density. An autocorrelation-based method for estimating the local, instantaneous, particle image density is presented. Synthetic images were used to develop an empirical relationship based on how the autocorrelation peak magnitude varies with particle image density, particle image diameter, illumination intensity, interrogation region size, and background noise. This relationship was then tested using images from two experimental setups with different seeding densities and flow media. The experimental results were compared to image densities obtained through using a local maximum method as well as manual particle counts and are found to be robust. The effect of varying particle image intensities was also investigated and is found to affect the particle image density."],"dc:description.note":["<p>This work made publicly available electronically on December 21, 2012.</p>"],"dc:identifier":["https://digitalcommons.usu.edu/etd/1386"],"dc:identifier.doi":["https://doi.org/10.26076/2d60-f804"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["autocorrelation","particle image density","particle image velocimetry","Mechanical Engineering"],"dc:title":["Autocorrelation-Based Estimate of Particle Image Density in Particle Image Velocimetry"],"thesis:degree_discipline":["Mechanical and Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:47:02Z"}