{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-2423"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-2423","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Simulation of Counterintuitive Pressure Drop in a Parallel Flow Design for a Specimen Basket for Use in the Advanced Test Reactor","abstract":"To continue improving nuclear energy, new materials must be tested in testing reactors such as the Advanced Test Reactor (ATR) at Idaho National Laboratory. A new test cap section allowed coolant to contact specimens tested in the ATR. A parallel channel test cap section should reduce the pressure drop across this section compared to a single channel. A fluid experiment conducted by Idaho State University showed the pressure drop was actually greater. A Computation Fluid Dynamics simulation using STAR-CCM+ was conducted of the fluid experiment to explain the abnormal pressure drop. The simulation provided evidence of ow through the test section required for a corrosion test and supported the results of the fluid experiment. Some pressure drop was caused by nozzle-like design and sudden expansion and contraction. Chaotic mixing produced some pressure drop. Flow disturbance related to flow rate caused a pressure drop at high flow rates when the fluid separated into each channel. The anomalous pressure drop was caused by the design of the test cap section.","abstract_html":"To continue improving nuclear energy, new materials must be tested in testing reactors such as the Advanced Test Reactor (ATR) at Idaho National Laboratory. A new test cap section allowed coolant to contact specimens tested in the ATR. A parallel channel test cap section should reduce the pressure drop across this section compared to a single channel. A fluid experiment conducted by Idaho State University showed the pressure drop was actually greater. A Computation Fluid Dynamics simulation using STAR-CCM+ was conducted of the fluid experiment to explain the abnormal pressure drop. The simulation provided evidence of ow through the test section required for a corrosion test and supported the results of the fluid experiment. Some pressure drop was caused by nozzle-like design and sudden expansion and contraction. Chaotic mixing produced some pressure drop. Flow disturbance related to flow rate caused a pressure drop at high flow rates when the fluid separated into each channel. The anomalous pressure drop was caused by the design of the test cap section.","abstract_has_math":false,"creators":["Zabriskie, Adam X."],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Heng Ban","Robert Spall","Leijun Li"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:47:02Z","subjects":["ATR","CFD","INL","Parallel Flow","Pressure Drop","Simulation","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/937d-f4c3"],"render_values":[{"text":"https://doi.org/10.26076/937d-f4c3","href":"https://doi.org/10.26076/937d-f4c3","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/1384","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/1384","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-2423","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Heng Ban","Robert Spall","Leijun Li"]},{"key":"dc:creator","label":"Author","values":["Zabriskie, Adam X."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2012-12-21T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2012-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ATR","CFD","INL","Parallel Flow","Pressure Drop","Simulation","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/1384"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/937d-f4c3"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["To continue improving nuclear energy, new materials must be tested in testing reactors such as the Advanced Test Reactor (ATR) at Idaho National Laboratory. A new test cap section allowed coolant to contact specimens tested in the ATR. A parallel channel test cap section should reduce the pressure drop across this section compared to a single channel. A fluid experiment conducted by Idaho State University showed the pressure drop was actually greater. A Computation Fluid Dynamics simulation using STAR-CCM+ was conducted of the fluid experiment to explain the abnormal pressure drop. The simulation provided evidence of ow through the test section required for a corrosion test and supported the results of the fluid experiment. Some pressure drop was caused by nozzle-like design and sudden expansion and contraction. Chaotic mixing produced some pressure drop. Flow disturbance related to flow rate caused a pressure drop at high flow rates when the fluid separated into each channel. The anomalous pressure drop was caused by the design of the test cap section."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>This work made publicly available electronically on December 21, 2012.</p>"]},{"key":"dc:title","label":"Title","values":["Simulation of Counterintuitive Pressure Drop in a Parallel Flow Design for a Specimen Basket for Use in the Advanced Test Reactor"]}]}],"canonical_facts":{"dc:contributor":["Heng Ban","Robert Spall","Leijun Li"],"dc:creator":["Zabriskie, Adam X."],"dc:date.available":["2012-12-21T08:00:00Z"],"dc:date.created":["2012-05-01T07:00:00Z"],"dc:description.abstract":["To continue improving nuclear energy, new materials must be tested in testing reactors such as the Advanced Test Reactor (ATR) at Idaho National Laboratory. A new test cap section allowed coolant to contact specimens tested in the ATR. A parallel channel test cap section should reduce the pressure drop across this section compared to a single channel. A fluid experiment conducted by Idaho State University showed the pressure drop was actually greater. A Computation Fluid Dynamics simulation using STAR-CCM+ was conducted of the fluid experiment to explain the abnormal pressure drop. The simulation provided evidence of ow through the test section required for a corrosion test and supported the results of the fluid experiment. Some pressure drop was caused by nozzle-like design and sudden expansion and contraction. Chaotic mixing produced some pressure drop. Flow disturbance related to flow rate caused a pressure drop at high flow rates when the fluid separated into each channel. The anomalous pressure drop was caused by the design of the test cap section."],"dc:description.note":["<p>This work made publicly available electronically on December 21, 2012.</p>"],"dc:identifier":["https://digitalcommons.usu.edu/etd/1384"],"dc:identifier.doi":["https://doi.org/10.26076/937d-f4c3"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["ATR","CFD","INL","Parallel Flow","Pressure Drop","Simulation","Mechanical Engineering"],"dc:title":["Simulation of Counterintuitive Pressure Drop in a Parallel Flow Design for a Specimen Basket for Use in the Advanced Test Reactor"],"thesis:degree_discipline":["Mechanical and Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:47:02Z"}