{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-3793"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-3793","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Occurrence and Removal of Ultra-Low Level Hexavalent Chromium in Drinking Water","abstract":"This project provides insight for drinking water utilities to better understand chromium behavior in their own waters. Seven full-scale treatment plants developed a snapshot profile of chromium behavior and treatability. If ultra-low level Cr6 is to be controlled, the key treatment processes in need of further investigation are lime softening, oxidation by chlorine, chloramines, or permanganate, and reduction-coupled coagulation using ferrous iron. Chlorine was shown to oxidize ultra-low levels of Cr3 to Cr6 in less than seven hours. The distribution system investigations showed the concentration of Cr6 could change between the point of entry and the tap. It is therefore stressed that Cr3 must also be removed during treatment; otherwise it may be oxidized and generate additional Cr6 during distribution. Other non-water sources of chromium including leaching of chromium-bearing infrastructure and trace contamination of treatment chemicals. Thirteen types of drinking water treatment chemicals were investigated. Twelve of the 13 chemicals contained negligible amounts of chromium, but iron-based coagulants contained significant levels of chromium that were inadvertently added to some treated waters.","abstract_html":"This project provides insight for drinking water utilities to better understand chromium behavior in their own waters. Seven full-scale treatment plants developed a snapshot profile of chromium behavior and treatability. If ultra-low level Cr6 is to be controlled, the key treatment processes in need of further investigation are lime softening, oxidation by chlorine, chloramines, or permanganate, and reduction-coupled coagulation using ferrous iron. Chlorine was shown to oxidize ultra-low levels of Cr3 to Cr6 in less than seven hours. The distribution system investigations showed the concentration of Cr6 could change between the point of entry and the tap. It is therefore stressed that Cr3 must also be removed during treatment; otherwise it may be oxidized and generate additional Cr6 during distribution. Other non-water sources of chromium including leaching of chromium-bearing infrastructure and trace contamination of treatment chemicals. Thirteen types of drinking water treatment chemicals were investigated. Twelve of the 13 chemicals contained negligible amounts of chromium, but iron-based coagulants contained significant levels of chromium that were inadvertently added to some treated waters.","abstract_has_math":false,"creators":["Olsen, Christel"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Laurie McNeill","Joan McLean","Eva Nieminski"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:47:44Z","subjects":["drinking water","hexavalent chromium","Civil and Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/8ce2-2242"],"render_values":[{"text":"https://doi.org/10.26076/8ce2-2242","href":"https://doi.org/10.26076/8ce2-2242","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/2770","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/2770","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-3793","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Laurie McNeill","Joan McLean","Eva Nieminski"]},{"key":"dc:creator","label":"Author","values":["Olsen, Christel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["drinking water","hexavalent chromium","Civil and Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/2770"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/8ce2-2242"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This project provides insight for drinking water utilities to better understand chromium behavior in their own waters. Seven full-scale treatment plants developed a snapshot profile of chromium behavior and treatability. If ultra-low level Cr6 is to be controlled, the key treatment processes in need of further investigation are lime softening, oxidation by chlorine, chloramines, or permanganate, and reduction-coupled coagulation using ferrous iron. Chlorine was shown to oxidize ultra-low levels of Cr3 to Cr6 in less than seven hours. The distribution system investigations showed the concentration of Cr6 could change between the point of entry and the tap. It is therefore stressed that Cr3 must also be removed during treatment; otherwise it may be oxidized and generate additional Cr6 during distribution. Other non-water sources of chromium including leaching of chromium-bearing infrastructure and trace contamination of treatment chemicals. Thirteen types of drinking water treatment chemicals were investigated. Twelve of the 13 chemicals contained negligible amounts of chromium, but iron-based coagulants contained significant levels of chromium that were inadvertently added to some treated waters."]},{"key":"dc:title","label":"Title","values":["Occurrence and Removal of Ultra-Low Level Hexavalent Chromium in Drinking Water"]}]}],"canonical_facts":{"dc:contributor":["Laurie McNeill","Joan McLean","Eva Nieminski"],"dc:creator":["Olsen, Christel"],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2014-05-01T07:00:00Z"],"dc:description.abstract":["This project provides insight for drinking water utilities to better understand chromium behavior in their own waters. Seven full-scale treatment plants developed a snapshot profile of chromium behavior and treatability. If ultra-low level Cr6 is to be controlled, the key treatment processes in need of further investigation are lime softening, oxidation by chlorine, chloramines, or permanganate, and reduction-coupled coagulation using ferrous iron. Chlorine was shown to oxidize ultra-low levels of Cr3 to Cr6 in less than seven hours. The distribution system investigations showed the concentration of Cr6 could change between the point of entry and the tap. It is therefore stressed that Cr3 must also be removed during treatment; otherwise it may be oxidized and generate additional Cr6 during distribution. Other non-water sources of chromium including leaching of chromium-bearing infrastructure and trace contamination of treatment chemicals. Thirteen types of drinking water treatment chemicals were investigated. Twelve of the 13 chemicals contained negligible amounts of chromium, but iron-based coagulants contained significant levels of chromium that were inadvertently added to some treated waters."],"dc:identifier":["https://digitalcommons.usu.edu/etd/2770"],"dc:identifier.doi":["https://doi.org/10.26076/8ce2-2242"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["drinking water","hexavalent chromium","Civil and Environmental Engineering"],"dc:title":["Occurrence and Removal of Ultra-Low Level Hexavalent Chromium in Drinking Water"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:47:44Z"}