{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-4322"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-4322","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Uncertainty Quantification of Photothermal Radiometry Measurements Using Monte Carlo Simulation and Experimental Repeatability","abstract":"Photothermal Radiometry is a common thermal property measurement technique which is used to measure the properties of layered materials. Photothermal Radiometry uses a modulated laser to heat a sample, in which the thermal response can be used to determine the thermal properties of layers in the sample. The motivation for this work is to provide a better understanding of the accuracy and the repeatability of the Photothermal Radiometry measurement technique. Through this work the sensitivity of results to input uncertainties will be determined. Additionally, using numerical simulations the overall uncertainty on a theoretical measurement will be determined. The repeatability of Photothermal Radiometry measurements is tested with the use of a proton irradiated zirconium carbide sample. Due to the proton irradiation this sample contains two layers with a thermal resistance between the layers. This sample has been independently measured by three different researchers, in three different countries and the results are compared to determine the repeatability of Photothermal Radiometry measurements. Finally, from sensitivity and uncertainty analysis experimental procedures and suggestions are provided to reduce the uncertainty in experimentally measured results.","abstract_html":"Photothermal Radiometry is a common thermal property measurement technique which is used to measure the properties of layered materials. Photothermal Radiometry uses a modulated laser to heat a sample, in which the thermal response can be used to determine the thermal properties of layers in the sample. The motivation for this work is to provide a better understanding of the accuracy and the repeatability of the Photothermal Radiometry measurement technique. Through this work the sensitivity of results to input uncertainties will be determined. Additionally, using numerical simulations the overall uncertainty on a theoretical measurement will be determined. The repeatability of Photothermal Radiometry measurements is tested with the use of a proton irradiated zirconium carbide sample. Due to the proton irradiation this sample contains two layers with a thermal resistance between the layers. This sample has been independently measured by three different researchers, in three different countries and the results are compared to determine the repeatability of Photothermal Radiometry measurements. Finally, from sensitivity and uncertainty analysis experimental procedures and suggestions are provided to reduce the uncertainty in experimentally measured results.","abstract_has_math":false,"creators":["Fleming, Austin"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Heng Ban","Nick Roberts","Robert Spall"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:48:01Z","subjects":["Uncertainty Quantification","Photothermal Radiometry Measurements","Monte Carlo Simulation","Experimental Repeatability","Aerospace Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/784f-6b26"],"render_values":[{"text":"https://doi.org/10.26076/784f-6b26","href":"https://doi.org/10.26076/784f-6b26","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/3299","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/3299","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-4322","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Heng Ban","Nick Roberts","Robert Spall"]},{"key":"dc:creator","label":"Author","values":["Fleming, Austin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Uncertainty Quantification","Photothermal Radiometry Measurements","Monte Carlo Simulation","Experimental Repeatability","Aerospace Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/3299"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/784f-6b26"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Photothermal Radiometry is a common thermal property measurement technique which is used to measure the properties of layered materials. Photothermal Radiometry uses a modulated laser to heat a sample, in which the thermal response can be used to determine the thermal properties of layers in the sample. The motivation for this work is to provide a better understanding of the accuracy and the repeatability of the Photothermal Radiometry measurement technique. Through this work the sensitivity of results to input uncertainties will be determined. Additionally, using numerical simulations the overall uncertainty on a theoretical measurement will be determined. The repeatability of Photothermal Radiometry measurements is tested with the use of a proton irradiated zirconium carbide sample. Due to the proton irradiation this sample contains two layers with a thermal resistance between the layers. This sample has been independently measured by three different researchers, in three different countries and the results are compared to determine the repeatability of Photothermal Radiometry measurements. Finally, from sensitivity and uncertainty analysis experimental procedures and suggestions are provided to reduce the uncertainty in experimentally measured results."]},{"key":"dc:title","label":"Title","values":["Uncertainty Quantification of Photothermal Radiometry Measurements Using Monte Carlo Simulation and Experimental Repeatability"]}]}],"canonical_facts":{"dc:contributor":["Heng Ban","Nick Roberts","Robert Spall"],"dc:creator":["Fleming, Austin"],"dc:date.available":["2014-01-01T08:00:00Z"],"dc:date.created":["2014-05-01T07:00:00Z"],"dc:description.abstract":["Photothermal Radiometry is a common thermal property measurement technique which is used to measure the properties of layered materials. Photothermal Radiometry uses a modulated laser to heat a sample, in which the thermal response can be used to determine the thermal properties of layers in the sample. The motivation for this work is to provide a better understanding of the accuracy and the repeatability of the Photothermal Radiometry measurement technique. Through this work the sensitivity of results to input uncertainties will be determined. Additionally, using numerical simulations the overall uncertainty on a theoretical measurement will be determined. The repeatability of Photothermal Radiometry measurements is tested with the use of a proton irradiated zirconium carbide sample. Due to the proton irradiation this sample contains two layers with a thermal resistance between the layers. This sample has been independently measured by three different researchers, in three different countries and the results are compared to determine the repeatability of Photothermal Radiometry measurements. Finally, from sensitivity and uncertainty analysis experimental procedures and suggestions are provided to reduce the uncertainty in experimentally measured results."],"dc:identifier":["https://digitalcommons.usu.edu/etd/3299"],"dc:identifier.doi":["https://doi.org/10.26076/784f-6b26"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Uncertainty Quantification","Photothermal Radiometry Measurements","Monte Carlo Simulation","Experimental Repeatability","Aerospace Engineering"],"dc:title":["Uncertainty Quantification of Photothermal Radiometry Measurements Using Monte Carlo Simulation and Experimental Repeatability"],"thesis:degree_discipline":["Mechanical and Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:48:01Z"}