{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-4899"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-4899","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Comparison of Selected Differential Producing, Ultrasonic, and Magnetic Flow Meters","abstract":"Flow meters are used to measure flow accurately. There are many different flow meters and it is necessary to know which will function best for specific situations. A wide variety of flow meters were selected for the study to assist in showing that each flow meter has its tradeoffs. The selected meters include: three types of Venturi meters, a wedge meter, a V-cone meter, an electromagnetic flow meter, and an ultrasonic flow meter. The characteristics researched in this study are discharge coefficient (Cd) over a range of Reynolds numbers (Re), head loss across each flow meter, life, and cost of meter. Each meter was tested over a wide range of Re to find the corresponding Cd and head loss. The life and cost of each meter were researched and estimated based on the flow meter companies and local distributor’s findings. With the findings, the tradeoffs are illustrated and will assist buyers in selecting a flow meter that will best fit their needs. While there are more flow meters available than was tested, the current study can direct buyers in a correct process of selecting meters for all situations.","abstract_html":"Flow meters are used to measure flow accurately. There are many different flow meters and it is necessary to know which will function best for specific situations. A wide variety of flow meters were selected for the study to assist in showing that each flow meter has its tradeoffs. The selected meters include: three types of Venturi meters, a wedge meter, a V-cone meter, an electromagnetic flow meter, and an ultrasonic flow meter. The characteristics researched in this study are discharge coefficient (Cd) over a range of Reynolds numbers (Re), head loss across each flow meter, life, and cost of meter. Each meter was tested over a wide range of Re to find the corresponding Cd and head loss. The life and cost of each meter were researched and estimated based on the flow meter companies and local distributor’s findings. With the findings, the tradeoffs are illustrated and will assist buyers in selecting a flow meter that will best fit their needs. While there are more flow meters available than was tested, the current study can direct buyers in a correct process of selecting meters for all situations.","abstract_has_math":false,"creators":["Prettyman, Johnny B."],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Michael C. Johnson","Steven L. Barfuss","Joseph A. Caliendo"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:59:04Z","subjects":["Selected Differential Producing","Ultrasonic","Magnetic Flow Meters","Civil and Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/0e15-9ef5"],"render_values":[{"text":"https://doi.org/10.26076/0e15-9ef5","href":"https://doi.org/10.26076/0e15-9ef5","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/3873","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/3873","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-4899","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Michael C. Johnson","Steven L. Barfuss","Joseph A. Caliendo"]},{"key":"dc:creator","label":"Author","values":["Prettyman, Johnny B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Selected Differential Producing","Ultrasonic","Magnetic Flow Meters","Civil and Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/3873"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/0e15-9ef5"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Flow meters are used to measure flow accurately. There are many different flow meters and it is necessary to know which will function best for specific situations. A wide variety of flow meters were selected for the study to assist in showing that each flow meter has its tradeoffs. The selected meters include: three types of Venturi meters, a wedge meter, a V-cone meter, an electromagnetic flow meter, and an ultrasonic flow meter. The characteristics researched in this study are discharge coefficient (Cd) over a range of Reynolds numbers (Re), head loss across each flow meter, life, and cost of meter. Each meter was tested over a wide range of Re to find the corresponding Cd and head loss. The life and cost of each meter were researched and estimated based on the flow meter companies and local distributor’s findings. With the findings, the tradeoffs are illustrated and will assist buyers in selecting a flow meter that will best fit their needs. While there are more flow meters available than was tested, the current study can direct buyers in a correct process of selecting meters for all situations."]},{"key":"dc:title","label":"Title","values":["Comparison of Selected Differential Producing, Ultrasonic, and Magnetic Flow Meters"]}]}],"canonical_facts":{"dc:contributor":["Michael C. Johnson","Steven L. Barfuss","Joseph A. Caliendo"],"dc:creator":["Prettyman, Johnny B."],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2014-05-01T07:00:00Z"],"dc:description.abstract":["Flow meters are used to measure flow accurately. There are many different flow meters and it is necessary to know which will function best for specific situations. A wide variety of flow meters were selected for the study to assist in showing that each flow meter has its tradeoffs. The selected meters include: three types of Venturi meters, a wedge meter, a V-cone meter, an electromagnetic flow meter, and an ultrasonic flow meter. The characteristics researched in this study are discharge coefficient (Cd) over a range of Reynolds numbers (Re), head loss across each flow meter, life, and cost of meter. Each meter was tested over a wide range of Re to find the corresponding Cd and head loss. The life and cost of each meter were researched and estimated based on the flow meter companies and local distributor’s findings. With the findings, the tradeoffs are illustrated and will assist buyers in selecting a flow meter that will best fit their needs. While there are more flow meters available than was tested, the current study can direct buyers in a correct process of selecting meters for all situations."],"dc:identifier":["https://digitalcommons.usu.edu/etd/3873"],"dc:identifier.doi":["https://doi.org/10.26076/0e15-9ef5"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Selected Differential Producing","Ultrasonic","Magnetic Flow Meters","Civil and Environmental Engineering"],"dc:title":["Comparison of Selected Differential Producing, Ultrasonic, and Magnetic Flow Meters"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:59:04Z"}