{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-4975"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-4975","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Aerating Butterfly Valves to Suppress Cavitation","abstract":"Proper aeration of cavitating hydraulic equipment can greatly reduce cavitation intensity, noise, and damage. This thesis quantifies the benefit, in terms of damage and noise, from aerating six inch butterfly valve. The incipient damage level of cavitation was obtained for both aerated and non-aerated conditions. The level is defined as one pit per square inch of a soft aluminum test specimen per one minute of operation. A description of the cavitation pits that occurred plus where they appeared is presented. A graph showing the aerated and non-aerated limits of incipient damage is given along with a table showing the percent reduction of damage from aeration. A graph and table are also given depicting the reduction in noise. The proper location of aeration ports to allow natural aeration is outlined.","abstract_html":"Proper aeration of cavitating hydraulic equipment can greatly reduce cavitation intensity, noise, and damage. This thesis quantifies the benefit, in terms of damage and noise, from aerating six inch butterfly valve. The incipient damage level of cavitation was obtained for both aerated and non-aerated conditions. The level is defined as one pit per square inch of a soft aluminum test specimen per one minute of operation. A description of the cavitation pits that occurred plus where they appeared is presented. A graph showing the aerated and non-aerated limits of incipient damage is given along with a table showing the percent reduction of damage from aeration. A graph and table are also given depicting the reduction in noise. The proper location of aeration ports to allow natural aeration is outlined.","abstract_has_math":false,"creators":["Davis, R. Ted"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["J. Paul Tullis","William Rahmeyer","Kern Stuttler"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:56:54Z","subjects":["Aerating Butterfly Valves","Cavitation Suppression","hydraulics","Civil and Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/6737-4cc4"],"render_values":[{"text":"https://doi.org/10.26076/6737-4cc4","href":"https://doi.org/10.26076/6737-4cc4","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/3952","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/3952","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-4975","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["J. Paul Tullis","William Rahmeyer","Kern Stuttler"]},{"key":"dc:creator","label":"Author","values":["Davis, R. Ted"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1986-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aerating Butterfly Valves","Cavitation Suppression","hydraulics","Civil and Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/3952"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/6737-4cc4"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Proper aeration of cavitating hydraulic equipment can greatly reduce cavitation intensity, noise, and damage. This thesis quantifies the benefit, in terms of damage and noise, from aerating six inch butterfly valve. The incipient damage level of cavitation was obtained for both aerated and non-aerated conditions. The level is defined as one pit per square inch of a soft aluminum test specimen per one minute of operation. A description of the cavitation pits that occurred plus where they appeared is presented. A graph showing the aerated and non-aerated limits of incipient damage is given along with a table showing the percent reduction of damage from aeration. A graph and table are also given depicting the reduction in noise. The proper location of aeration ports to allow natural aeration is outlined."]},{"key":"dc:title","label":"Title","values":["Aerating Butterfly Valves to Suppress Cavitation"]}]}],"canonical_facts":{"dc:contributor":["J. Paul Tullis","William Rahmeyer","Kern Stuttler"],"dc:creator":["Davis, R. Ted"],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["1986-05-01T07:00:00Z"],"dc:description.abstract":["Proper aeration of cavitating hydraulic equipment can greatly reduce cavitation intensity, noise, and damage. This thesis quantifies the benefit, in terms of damage and noise, from aerating six inch butterfly valve. The incipient damage level of cavitation was obtained for both aerated and non-aerated conditions. The level is defined as one pit per square inch of a soft aluminum test specimen per one minute of operation. A description of the cavitation pits that occurred plus where they appeared is presented. A graph showing the aerated and non-aerated limits of incipient damage is given along with a table showing the percent reduction of damage from aeration. A graph and table are also given depicting the reduction in noise. The proper location of aeration ports to allow natural aeration is outlined."],"dc:identifier":["https://digitalcommons.usu.edu/etd/3952"],"dc:identifier.doi":["https://doi.org/10.26076/6737-4cc4"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Aerating Butterfly Valves","Cavitation Suppression","hydraulics","Civil and Environmental Engineering"],"dc:title":["Aerating Butterfly Valves to Suppress Cavitation"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:56:54Z"}