{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-5122"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-5122","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Effects of Land Use on Water Quality: Summit Creek, Smithfield, Utah","abstract":"The effects of various land uses on water quality in Summit Creek were evaluated during the period beginning March 13, 1971 and ending October 27, 1971. Potential sources of pollution investigated were: (1) septic tank use, (2) feedlot runoff, (3) urban runoff, (4) rural runoff. Samples were collected from five sampling stations on 16 separate days during the sampling period. Analyses were performed to determine the following constituents: ammonia, nitrite, nitrate, total phosphorus, orthophosphate, coliform bacteria, chloride, suspended solids, volatile suspended solids, total carbon, organic carbon, temperature and pH. Agricultural activities, including livestock feedlot operations, were identified as the major source of pollutant inputs to Summit Creek. No significant pollutant inputs could be attributed to septic tank use, urban runoff, or rural runoff.","abstract_html":"The effects of various land uses on water quality in Summit Creek were evaluated during the period beginning March 13, 1971 and ending October 27, 1971. Potential sources of pollution investigated were: (1) septic tank use, (2) feedlot runoff, (3) urban runoff, (4) rural runoff. Samples were collected from five sampling stations on 16 separate days during the sampling period. Analyses were performed to determine the following constituents: ammonia, nitrite, nitrate, total phosphorus, orthophosphate, coliform bacteria, chloride, suspended solids, volatile suspended solids, total carbon, organic carbon, temperature and pH. Agricultural activities, including livestock feedlot operations, were identified as the major source of pollutant inputs to Summit Creek. No significant pollutant inputs could be attributed to septic tank use, urban runoff, or rural runoff.","abstract_has_math":false,"creators":["Meyers, David W."],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["E. J. Middlebrooks","D. B. Porcella","R. A. Gearheart"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:54:05Z","subjects":["Civil Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/28e9-ff8f"],"render_values":[{"text":"https://doi.org/10.26076/28e9-ff8f","href":"https://doi.org/10.26076/28e9-ff8f","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/4124","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/4124","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-5122","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["E. J. Middlebrooks","D. B. Porcella","R. A. Gearheart"]},{"key":"dc:creator","label":"Author","values":["Meyers, David W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1972-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/4124"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/28e9-ff8f"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The effects of various land uses on water quality in Summit Creek were evaluated during the period beginning March 13, 1971 and ending October 27, 1971. Potential sources of pollution investigated were: (1) septic tank use, (2) feedlot runoff, (3) urban runoff, (4) rural runoff. Samples were collected from five sampling stations on 16 separate days during the sampling period. Analyses were performed to determine the following constituents: ammonia, nitrite, nitrate, total phosphorus, orthophosphate, coliform bacteria, chloride, suspended solids, volatile suspended solids, total carbon, organic carbon, temperature and pH. Agricultural activities, including livestock feedlot operations, were identified as the major source of pollutant inputs to Summit Creek. No significant pollutant inputs could be attributed to septic tank use, urban runoff, or rural runoff."]},{"key":"dc:title","label":"Title","values":["Effects of Land Use on Water Quality: Summit Creek, Smithfield, Utah"]}]}],"canonical_facts":{"dc:contributor":["E. J. Middlebrooks","D. B. Porcella","R. A. Gearheart"],"dc:creator":["Meyers, David W."],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["1972-05-01T07:00:00Z"],"dc:description.abstract":["The effects of various land uses on water quality in Summit Creek were evaluated during the period beginning March 13, 1971 and ending October 27, 1971. Potential sources of pollution investigated were: (1) septic tank use, (2) feedlot runoff, (3) urban runoff, (4) rural runoff. Samples were collected from five sampling stations on 16 separate days during the sampling period. Analyses were performed to determine the following constituents: ammonia, nitrite, nitrate, total phosphorus, orthophosphate, coliform bacteria, chloride, suspended solids, volatile suspended solids, total carbon, organic carbon, temperature and pH. Agricultural activities, including livestock feedlot operations, were identified as the major source of pollutant inputs to Summit Creek. No significant pollutant inputs could be attributed to septic tank use, urban runoff, or rural runoff."],"dc:identifier":["https://digitalcommons.usu.edu/etd/4124"],"dc:identifier.doi":["https://doi.org/10.26076/28e9-ff8f"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Civil Engineering"],"dc:title":["Effects of Land Use on Water Quality: Summit Creek, Smithfield, Utah"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:54:05Z"}