{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-6312"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-6312","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Uncertainty of Stereo PIV Calibration and Self-Calibration","abstract":"Particle image velocimetry (PIV) is a widely used fluid measurement technique. Three dimensional PIV data or stereo PIV is acquired using two cameras. Stereo cameras are calibrated from camera coordinates, pixels, to real world units such as millimeters using calibration models. Stereo calibration is fundamental to the accuracy of a PIV measurement. In this thesis, the accuracy of the stereo calibration is assessed. The mean error of stereo calibration was found to be 0.23%.","abstract_html":"Particle image velocimetry (PIV) is a widely used fluid measurement technique. Three dimensional PIV data or stereo PIV is acquired using two cameras. Stereo cameras are calibrated from camera coordinates, pixels, to real world units such as millimeters using calibration models. Stereo calibration is fundamental to the accuracy of a PIV measurement. In this thesis, the accuracy of the stereo calibration is assessed. The mean error of stereo calibration was found to be 0.23%.","abstract_has_math":false,"creators":["Williams, Braydon J"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Barton L. Smith","Tadd Truscott","Ryan Berke"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:49:10Z","subjects":["PIV","Measurement Uncertainty","Other Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/0afb-0b83"],"render_values":[{"text":"https://doi.org/10.26076/0afb-0b83","href":"https://doi.org/10.26076/0afb-0b83","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/5263","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/5263","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-6312","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Barton L. Smith","Tadd Truscott","Ryan Berke"]},{"key":"dc:creator","label":"Author","values":["Williams, Braydon J"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["PIV","Measurement Uncertainty","Other Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/5263"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/0afb-0b83"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Particle image velocimetry (PIV) is a widely used fluid measurement technique. Three dimensional PIV data or stereo PIV is acquired using two cameras. Stereo cameras are calibrated from camera coordinates, pixels, to real world units such as millimeters using calibration models. Stereo calibration is fundamental to the accuracy of a PIV measurement. In this thesis, the accuracy of the stereo calibration is assessed. The mean error of stereo calibration was found to be 0.23%."]},{"key":"dc:title","label":"Title","values":["Uncertainty of Stereo PIV Calibration and Self-Calibration"]}]}],"canonical_facts":{"dc:contributor":["Barton L. Smith","Tadd Truscott","Ryan Berke"],"dc:creator":["Williams, Braydon J"],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2017-05-01T07:00:00Z"],"dc:description.abstract":["Particle image velocimetry (PIV) is a widely used fluid measurement technique. Three dimensional PIV data or stereo PIV is acquired using two cameras. Stereo cameras are calibrated from camera coordinates, pixels, to real world units such as millimeters using calibration models. Stereo calibration is fundamental to the accuracy of a PIV measurement. In this thesis, the accuracy of the stereo calibration is assessed. The mean error of stereo calibration was found to be 0.23%."],"dc:identifier":["https://digitalcommons.usu.edu/etd/5263"],"dc:identifier.doi":["https://doi.org/10.26076/0afb-0b83"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["PIV","Measurement Uncertainty","Other Engineering"],"dc:title":["Uncertainty of Stereo PIV Calibration and Self-Calibration"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical and Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:49:10Z"}