{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-6382"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-6382","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Detection of Abnormal Milk with Impedance Microbiology Instrumentation","abstract":"Mastitic milk was detected by obtaining conductance measurements using an impedance microbiology Bactometer® 120 SC instruments. Conductance readings taken after 30 min at 25'C separated normal and abnormal milks when readings differed by more than 3% from the variance among instrument module wells. Samples blended from four quarters of a cow indicated milk from one quarter was abnormal if the salt level in the abnormal quarter raised the blend conductivity above that of normal samples and variance among the wells. Either solid or liquid substrates that contained bacterial stimulants could be used to accelerate bacterial acid production or to reduce impedance detection times, each without adversely affecting the ability to detect abnormal milk. However, measurements with liquid substrates varied with the volume of sample in the well. Results suggested that a fixed volume of one ml be used. Such a volume would allow simultaneous detection of abnormal milk and bacterial load on the same sample.","abstract_html":"Mastitic milk was detected by obtaining conductance measurements using an impedance microbiology Bactometer® 120 SC instruments. Conductance readings taken after 30 min at 25&#x27;C separated normal and abnormal milks when readings differed by more than 3% from the variance among instrument module wells. Samples blended from four quarters of a cow indicated milk from one quarter was abnormal if the salt level in the abnormal quarter raised the blend conductivity above that of normal samples and variance among the wells. Either solid or liquid substrates that contained bacterial stimulants could be used to accelerate bacterial acid production or to reduce impedance detection times, each without adversely affecting the ability to detect abnormal milk. However, measurements with liquid substrates varied with the volume of sample in the well. Results suggested that a fixed volume of one ml be used. Such a volume would allow simultaneous detection of abnormal milk and bacterial load on the same sample.","abstract_has_math":false,"creators":["Khayat, Fahad Ali Abdulghany"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Biology","degree_department":null,"school":null,"contributors":["Frederick J. Post","Gary H. Richardson","F. J. Post"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:56:54Z","subjects":["Abnormal Milk","impedance","microbiology instrumentation","Biology","Life Sciences"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/de72-9be4"],"render_values":[{"text":"https://doi.org/10.26076/de72-9be4","href":"https://doi.org/10.26076/de72-9be4","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/5332","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/5332","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-6382","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Frederick J. Post","Gary H. Richardson","F. J. Post"]},{"key":"dc:creator","label":"Author","values":["Khayat, Fahad Ali Abdulghany"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1986-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Abnormal Milk","impedance","microbiology instrumentation","Biology","Life Sciences"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/5332"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/de72-9be4"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Mastitic milk was detected by obtaining conductance measurements using an impedance microbiology Bactometer® 120 SC instruments. Conductance readings taken after 30 min at 25'C separated normal and abnormal milks when readings differed by more than 3% from the variance among instrument module wells. Samples blended from four quarters of a cow indicated milk from one quarter was abnormal if the salt level in the abnormal quarter raised the blend conductivity above that of normal samples and variance among the wells. Either solid or liquid substrates that contained bacterial stimulants could be used to accelerate bacterial acid production or to reduce impedance detection times, each without adversely affecting the ability to detect abnormal milk. However, measurements with liquid substrates varied with the volume of sample in the well. Results suggested that a fixed volume of one ml be used. Such a volume would allow simultaneous detection of abnormal milk and bacterial load on the same sample."]},{"key":"dc:title","label":"Title","values":["Detection of Abnormal Milk with Impedance Microbiology Instrumentation"]}]}],"canonical_facts":{"dc:contributor":["Frederick J. Post","Gary H. Richardson","F. J. Post"],"dc:creator":["Khayat, Fahad Ali Abdulghany"],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["1986-05-01T07:00:00Z"],"dc:description.abstract":["Mastitic milk was detected by obtaining conductance measurements using an impedance microbiology Bactometer® 120 SC instruments. Conductance readings taken after 30 min at 25'C separated normal and abnormal milks when readings differed by more than 3% from the variance among instrument module wells. Samples blended from four quarters of a cow indicated milk from one quarter was abnormal if the salt level in the abnormal quarter raised the blend conductivity above that of normal samples and variance among the wells. Either solid or liquid substrates that contained bacterial stimulants could be used to accelerate bacterial acid production or to reduce impedance detection times, each without adversely affecting the ability to detect abnormal milk. However, measurements with liquid substrates varied with the volume of sample in the well. Results suggested that a fixed volume of one ml be used. Such a volume would allow simultaneous detection of abnormal milk and bacterial load on the same sample."],"dc:identifier":["https://digitalcommons.usu.edu/etd/5332"],"dc:identifier.doi":["https://doi.org/10.26076/de72-9be4"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Abnormal Milk","impedance","microbiology instrumentation","Biology","Life Sciences"],"dc:title":["Detection of Abnormal Milk with Impedance Microbiology Instrumentation"],"thesis:degree_discipline":["Biology"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:56:54Z"}