{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-7401"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-7401","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Best Practices for Volume Flow Rate Measurements Using PIV at the Exit of a Turbulent Round Jet","abstract":"Particle image velocimetry (PIV) is an optical flow measurement technique that is used to measure volume flow rate at the exit of a turbulent, round nozzle. The objective of this thesis is to determine how to best make this measurement. The quality of the measurement is affected by a range of data acquisition parameters and how data are processed. Measurements are made over a range of different flows using the two main types of PIV: Two Component (2C), which uses one camera, and Stereo, which uses two cameras, similar to human eyes. Previous work done for data acquisition and processing of PIV in general is found to apply. Different parameters are tested, evaluated, and discussed. Both 2C PIV and Stereo PIV were found to underestimate flow by approximately 2%.","abstract_html":"Particle image velocimetry (PIV) is an optical flow measurement technique that is used to measure volume flow rate at the exit of a turbulent, round nozzle. The objective of this thesis is to determine how to best make this measurement. The quality of the measurement is affected by a range of data acquisition parameters and how data are processed. Measurements are made over a range of different flows using the two main types of PIV: Two Component (2C), which uses one camera, and Stereo, which uses two cameras, similar to human eyes. Previous work done for data acquisition and processing of PIV in general is found to apply. Different parameters are tested, evaluated, and discussed. Both 2C PIV and Stereo PIV were found to underestimate flow by approximately 2%.","abstract_has_math":false,"creators":["Schaap, Robert"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Barton Smith","Geordie Richards","Nicholas Roberts"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:50:08Z","subjects":["Measurement uncertainty","PIV","Volume Flow Rate","Turbulent Round Jet","Aerospace Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/fc9c-6f41"],"render_values":[{"text":"https://doi.org/10.26076/fc9c-6f41","href":"https://doi.org/10.26076/fc9c-6f41","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/6274","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/6274","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-7401","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Barton Smith","Geordie Richards","Nicholas Roberts"]},{"key":"dc:creator","label":"Author","values":["Schaap, Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2022-07-05T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-08-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Measurement uncertainty","PIV","Volume Flow Rate","Turbulent Round Jet","Aerospace Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/6274"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/fc9c-6f41"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Particle image velocimetry (PIV) is an optical flow measurement technique that is used to measure volume flow rate at the exit of a turbulent, round nozzle. The objective of this thesis is to determine how to best make this measurement. The quality of the measurement is affected by a range of data acquisition parameters and how data are processed. Measurements are made over a range of different flows using the two main types of PIV: Two Component (2C), which uses one camera, and Stereo, which uses two cameras, similar to human eyes. Previous work done for data acquisition and processing of PIV in general is found to apply. Different parameters are tested, evaluated, and discussed. Both 2C PIV and Stereo PIV were found to underestimate flow by approximately 2%."]},{"key":"dc:title","label":"Title","values":["Best Practices for Volume Flow Rate Measurements Using PIV at the Exit of a Turbulent Round Jet"]}]}],"canonical_facts":{"dc:contributor":["Barton Smith","Geordie Richards","Nicholas Roberts"],"dc:creator":["Schaap, Robert"],"dc:date.available":["2022-07-05T07:00:00Z"],"dc:date.created":["2017-08-01T07:00:00Z"],"dc:description.abstract":["Particle image velocimetry (PIV) is an optical flow measurement technique that is used to measure volume flow rate at the exit of a turbulent, round nozzle. The objective of this thesis is to determine how to best make this measurement. The quality of the measurement is affected by a range of data acquisition parameters and how data are processed. Measurements are made over a range of different flows using the two main types of PIV: Two Component (2C), which uses one camera, and Stereo, which uses two cameras, similar to human eyes. Previous work done for data acquisition and processing of PIV in general is found to apply. Different parameters are tested, evaluated, and discussed. Both 2C PIV and Stereo PIV were found to underestimate flow by approximately 2%."],"dc:identifier":["https://digitalcommons.usu.edu/etd/6274"],"dc:identifier.doi":["https://doi.org/10.26076/fc9c-6f41"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Measurement uncertainty","PIV","Volume Flow Rate","Turbulent Round Jet","Aerospace Engineering"],"dc:title":["Best Practices for Volume Flow Rate Measurements Using PIV at the Exit of a Turbulent Round Jet"],"thesis:degree_discipline":["Mechanical and Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:50:08Z"}