{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-7769"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-7769","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Developing a General Methodology for Evaluating Composite Action in Insulated Wall Panels","abstract":"Precast Concrete Sandwich Panel Walls (PCSPW’s) have been in use for over 60 years. They provide a very efficient building envelope for many buildings. Characteristic PCSPW’s comprise an outer and inner layer (or wythe) of concrete separated by an insulating material. To use all of the material as efficiently as possible, the layers are attached by connectors which penetrate through the insulating layer and are embedded in either concrete wythe. These connectors make it possible for both layers of the wall to work together when resisting loads. The connectors are made out of plastic, or FRP, to prevent heat transfer from one side of the wall to the other. This research is evaluates several different FRP systems by fabricating and testing 49 small scale “push-off” specimens (3 ft. by 4 ft., 0.91 m by 1.22 m). Testing of these specimens is done by applying loads perpendicular to the connectors and measuring the amount of deformation that occurs. By determining the load to deformation relationship, engineers can make more informed decisions about the full scale behavior. Using this information, the goal of this project is to validate current procedures and develop simpler, more efficient methods for predicting overall strength of this innovative building system.","abstract_html":"Precast Concrete Sandwich Panel Walls (PCSPW’s) have been in use for over 60 years. They provide a very efficient building envelope for many buildings. Characteristic PCSPW’s comprise an outer and inner layer (or wythe) of concrete separated by an insulating material. To use all of the material as efficiently as possible, the layers are attached by connectors which penetrate through the insulating layer and are embedded in either concrete wythe. These connectors make it possible for both layers of the wall to work together when resisting loads. The connectors are made out of plastic, or FRP, to prevent heat transfer from one side of the wall to the other. This research is evaluates several different FRP systems by fabricating and testing 49 small scale “push-off” specimens (3 ft. by 4 ft., 0.91 m by 1.22 m). Testing of these specimens is done by applying loads perpendicular to the connectors and measuring the amount of deformation that occurs. By determining the load to deformation relationship, engineers can make more informed decisions about the full scale behavior. Using this information, the goal of this project is to validate current procedures and develop simpler, more efficient methods for predicting overall strength of this innovative building system.","abstract_has_math":false,"creators":["Olsen, Jaiden Thomas"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Marc Maguire","Joseph A. Caliendo","Paul Barr"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:59:12Z","subjects":["general methodology","composite action","insulated wall panels","evaluating","Civil Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/50b2-d37b"],"render_values":[{"text":"https://doi.org/10.26076/50b2-d37b","href":"https://doi.org/10.26076/50b2-d37b","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/6548","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/6548","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-7769","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Marc Maguire","Joseph A. Caliendo","Paul Barr"]},{"key":"dc:creator","label":"Author","values":["Olsen, Jaiden Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["general methodology","composite action","insulated wall panels","evaluating","Civil Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/6548"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/50b2-d37b"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Precast Concrete Sandwich Panel Walls (PCSPW’s) have been in use for over 60 years. They provide a very efficient building envelope for many buildings. Characteristic PCSPW’s comprise an outer and inner layer (or wythe) of concrete separated by an insulating material. To use all of the material as efficiently as possible, the layers are attached by connectors which penetrate through the insulating layer and are embedded in either concrete wythe. These connectors make it possible for both layers of the wall to work together when resisting loads. The connectors are made out of plastic, or FRP, to prevent heat transfer from one side of the wall to the other. This research is evaluates several different FRP systems by fabricating and testing 49 small scale “push-off” specimens (3 ft. by 4 ft., 0.91 m by 1.22 m). Testing of these specimens is done by applying loads perpendicular to the connectors and measuring the amount of deformation that occurs. By determining the load to deformation relationship, engineers can make more informed decisions about the full scale behavior. Using this information, the goal of this project is to validate current procedures and develop simpler, more efficient methods for predicting overall strength of this innovative building system."]},{"key":"dc:title","label":"Title","values":["Developing a General Methodology for Evaluating Composite Action in Insulated Wall Panels"]}]}],"canonical_facts":{"dc:contributor":["Marc Maguire","Joseph A. Caliendo","Paul Barr"],"dc:creator":["Olsen, Jaiden Thomas"],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2017-05-01T07:00:00Z"],"dc:description.abstract":["Precast Concrete Sandwich Panel Walls (PCSPW’s) have been in use for over 60 years. They provide a very efficient building envelope for many buildings. Characteristic PCSPW’s comprise an outer and inner layer (or wythe) of concrete separated by an insulating material. To use all of the material as efficiently as possible, the layers are attached by connectors which penetrate through the insulating layer and are embedded in either concrete wythe. These connectors make it possible for both layers of the wall to work together when resisting loads. The connectors are made out of plastic, or FRP, to prevent heat transfer from one side of the wall to the other. This research is evaluates several different FRP systems by fabricating and testing 49 small scale “push-off” specimens (3 ft. by 4 ft., 0.91 m by 1.22 m). Testing of these specimens is done by applying loads perpendicular to the connectors and measuring the amount of deformation that occurs. By determining the load to deformation relationship, engineers can make more informed decisions about the full scale behavior. Using this information, the goal of this project is to validate current procedures and develop simpler, more efficient methods for predicting overall strength of this innovative building system."],"dc:identifier":["https://digitalcommons.usu.edu/etd/6548"],"dc:identifier.doi":["https://doi.org/10.26076/50b2-d37b"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["general methodology","composite action","insulated wall panels","evaluating","Civil Engineering"],"dc:title":["Developing a General Methodology for Evaluating Composite Action in Insulated Wall Panels"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:59:12Z"}