{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-8140"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-8140","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Assessing the Effects of Local Turbulence and Velocity Profiles on Electromagnetic Flow Meter Accuracy","abstract":"The purpose of this research was to assess the effects of local turbulence and velocity profiles on electromagnetic (magnetic) flow meters. According to the American Water Works Association, “No tool available to water utilities has played a greater part in the conservation of water than the water meter (AWWA 2002).” Consequently, it is imperative to understand what variables may influence magnetic flow meter accuracy. Even though other researchers have explored the effects of turbulence profile development on orifice plates, the literature is not clear how magnetic flow meters respond to the effect of local turbulence. Accordingly, this study investigated the effects of local turbulence and velocity profiles on magnetic flow meter accuracy. Using five magnetic flow meters from five different manufacturers, laboratory tests were conducted with a CPA 65E flow conditioner located at different distances upstream of the meter. Numerical modeling using commercially available computational fluid dynamics software indicated that the deviations in flow meter accuracy were not proportional to the levels of local turbulence. It appears that magnetic flow meters may only be influenced by local turbulence to the degree that the upstream disturbance that distorts the velocity profile also increases local turbulence.","abstract_html":"The purpose of this research was to assess the effects of local turbulence and velocity profiles on electromagnetic (magnetic) flow meters. According to the American Water Works Association, “No tool available to water utilities has played a greater part in the conservation of water than the water meter (AWWA 2002).” Consequently, it is imperative to understand what variables may influence magnetic flow meter accuracy. Even though other researchers have explored the effects of turbulence profile development on orifice plates, the literature is not clear how magnetic flow meters respond to the effect of local turbulence. Accordingly, this study investigated the effects of local turbulence and velocity profiles on magnetic flow meter accuracy. Using five magnetic flow meters from five different manufacturers, laboratory tests were conducted with a CPA 65E flow conditioner located at different distances upstream of the meter. Numerical modeling using commercially available computational fluid dynamics software indicated that the deviations in flow meter accuracy were not proportional to the levels of local turbulence. It appears that magnetic flow meters may only be influenced by local turbulence to the degree that the upstream disturbance that distorts the velocity profile also increases local turbulence.","abstract_has_math":false,"creators":["Beck, Kade J."],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Steven L. Barfuss","Michael C. Johnson","Reyhan Baktur"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:50:32Z","subjects":["Accuracy","Turbulence","Electromagnetic","Velocity Profiles","Meter","Civil and Environmental Engineering","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/fa51-b7f8"],"render_values":[{"text":"https://doi.org/10.26076/fa51-b7f8","href":"https://doi.org/10.26076/fa51-b7f8","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/7033","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/7033","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-8140","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Steven L. Barfuss","Michael C. Johnson","Reyhan Baktur"]},{"key":"dc:creator","label":"Author","values":["Beck, Kade J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Accuracy","Turbulence","Electromagnetic","Velocity Profiles","Meter","Civil and Environmental Engineering","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/7033"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/fa51-b7f8"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this research was to assess the effects of local turbulence and velocity profiles on electromagnetic (magnetic) flow meters. According to the American Water Works Association, “No tool available to water utilities has played a greater part in the conservation of water than the water meter (AWWA 2002).” Consequently, it is imperative to understand what variables may influence magnetic flow meter accuracy. Even though other researchers have explored the effects of turbulence profile development on orifice plates, the literature is not clear how magnetic flow meters respond to the effect of local turbulence. Accordingly, this study investigated the effects of local turbulence and velocity profiles on magnetic flow meter accuracy. Using five magnetic flow meters from five different manufacturers, laboratory tests were conducted with a CPA 65E flow conditioner located at different distances upstream of the meter. Numerical modeling using commercially available computational fluid dynamics software indicated that the deviations in flow meter accuracy were not proportional to the levels of local turbulence. It appears that magnetic flow meters may only be influenced by local turbulence to the degree that the upstream disturbance that distorts the velocity profile also increases local turbulence."]},{"key":"dc:title","label":"Title","values":["Assessing the Effects of Local Turbulence and Velocity Profiles on Electromagnetic Flow Meter Accuracy"]}]}],"canonical_facts":{"dc:contributor":["Steven L. Barfuss","Michael C. Johnson","Reyhan Baktur"],"dc:creator":["Beck, Kade J."],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2018-05-01T07:00:00Z"],"dc:description.abstract":["The purpose of this research was to assess the effects of local turbulence and velocity profiles on electromagnetic (magnetic) flow meters. According to the American Water Works Association, “No tool available to water utilities has played a greater part in the conservation of water than the water meter (AWWA 2002).” Consequently, it is imperative to understand what variables may influence magnetic flow meter accuracy. Even though other researchers have explored the effects of turbulence profile development on orifice plates, the literature is not clear how magnetic flow meters respond to the effect of local turbulence. Accordingly, this study investigated the effects of local turbulence and velocity profiles on magnetic flow meter accuracy. Using five magnetic flow meters from five different manufacturers, laboratory tests were conducted with a CPA 65E flow conditioner located at different distances upstream of the meter. Numerical modeling using commercially available computational fluid dynamics software indicated that the deviations in flow meter accuracy were not proportional to the levels of local turbulence. It appears that magnetic flow meters may only be influenced by local turbulence to the degree that the upstream disturbance that distorts the velocity profile also increases local turbulence."],"dc:identifier":["https://digitalcommons.usu.edu/etd/7033"],"dc:identifier.doi":["https://doi.org/10.26076/fa51-b7f8"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Accuracy","Turbulence","Electromagnetic","Velocity Profiles","Meter","Civil and Environmental Engineering","Engineering"],"dc:title":["Assessing the Effects of Local Turbulence and Velocity Profiles on Electromagnetic Flow Meter Accuracy"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:50:32Z"}