{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-8488"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-8488","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Analysis of Cutthroat Flume Discharge Ratings","abstract":"Sixteeen sets of original laboratory data collected by many investigators for various Cutthroat flume sizes are thoroughly reviewed and organized. Best-fit discharge parameters are obtained by performing the free-flow analysis and the submerged-flow analysis. Then, the transition submergence can be calculated. Afterwards, the unified free-flow and submerged-flow discharge parameters are developed for each flume size in order to generalize the calibrations for Cutthroat flumes. This is a very tedious process requiring a trial-and-error approach. Finally, comparisons are made of the measured laboratory discharges with the predicted discharges for both free flow and submerged flow using both the best-fit and the unified discharge parameters. The results proved quite good as measured by the standard deviation for each flume size. In most cases, the average standard deviation using the unified discharge parameters was only slightly greater than when using the best-fit discharge parameters. However, there is a significant difference in the accuracy of free-flow measurements compared with submerged-flow measurements. Using the unified discharge parameters, the mean standard deviation for all of the flumes was 2.1 percent for free flow and 6.5 percent for submerged flow.","abstract_html":"Sixteeen sets of original laboratory data collected by many investigators for various Cutthroat flume sizes are thoroughly reviewed and organized. Best-fit discharge parameters are obtained by performing the free-flow analysis and the submerged-flow analysis. Then, the transition submergence can be calculated. Afterwards, the unified free-flow and submerged-flow discharge parameters are developed for each flume size in order to generalize the calibrations for Cutthroat flumes. This is a very tedious process requiring a trial-and-error approach. Finally, comparisons are made of the measured laboratory discharges with the predicted discharges for both free flow and submerged flow using both the best-fit and the unified discharge parameters. The results proved quite good as measured by the standard deviation for each flume size. In most cases, the average standard deviation using the unified discharge parameters was only slightly greater than when using the best-fit discharge parameters. However, there is a significant difference in the accuracy of free-flow measurements compared with submerged-flow measurements. Using the unified discharge parameters, the mean standard deviation for all of the flumes was 2.1 percent for free flow and 6.5 percent for submerged flow.","abstract_has_math":false,"creators":["Ren, Liyan"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Gaylord V. Skogerboe","Roland W. Jeppson","Gary P. Merkley"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:57:13Z","subjects":["cutthroat flume","flume","discharge parameters","submerged flow","free flow","Biological Engineering","Other Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/0ef4-394e"],"render_values":[{"text":"https://doi.org/10.26076/0ef4-394e","href":"https://doi.org/10.26076/0ef4-394e","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/7369","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/7369","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-8488","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gaylord V. Skogerboe","Roland W. Jeppson","Gary P. Merkley"]},{"key":"dc:creator","label":"Author","values":["Ren, Liyan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1993-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["cutthroat flume","flume","discharge parameters","submerged flow","free flow","Biological Engineering","Other Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/7369"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/0ef4-394e"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Sixteeen sets of original laboratory data collected by many investigators for various Cutthroat flume sizes are thoroughly reviewed and organized. Best-fit discharge parameters are obtained by performing the free-flow analysis and the submerged-flow analysis. Then, the transition submergence can be calculated. Afterwards, the unified free-flow and submerged-flow discharge parameters are developed for each flume size in order to generalize the calibrations for Cutthroat flumes. This is a very tedious process requiring a trial-and-error approach. Finally, comparisons are made of the measured laboratory discharges with the predicted discharges for both free flow and submerged flow using both the best-fit and the unified discharge parameters. The results proved quite good as measured by the standard deviation for each flume size. In most cases, the average standard deviation using the unified discharge parameters was only slightly greater than when using the best-fit discharge parameters. However, there is a significant difference in the accuracy of free-flow measurements compared with submerged-flow measurements. Using the unified discharge parameters, the mean standard deviation for all of the flumes was 2.1 percent for free flow and 6.5 percent for submerged flow."]},{"key":"dc:title","label":"Title","values":["Analysis of Cutthroat Flume Discharge Ratings"]}]}],"canonical_facts":{"dc:contributor":["Gaylord V. Skogerboe","Roland W. Jeppson","Gary P. Merkley"],"dc:creator":["Ren, Liyan"],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["1993-05-01T07:00:00Z"],"dc:description.abstract":["Sixteeen sets of original laboratory data collected by many investigators for various Cutthroat flume sizes are thoroughly reviewed and organized. Best-fit discharge parameters are obtained by performing the free-flow analysis and the submerged-flow analysis. Then, the transition submergence can be calculated. Afterwards, the unified free-flow and submerged-flow discharge parameters are developed for each flume size in order to generalize the calibrations for Cutthroat flumes. This is a very tedious process requiring a trial-and-error approach. Finally, comparisons are made of the measured laboratory discharges with the predicted discharges for both free flow and submerged flow using both the best-fit and the unified discharge parameters. The results proved quite good as measured by the standard deviation for each flume size. In most cases, the average standard deviation using the unified discharge parameters was only slightly greater than when using the best-fit discharge parameters. However, there is a significant difference in the accuracy of free-flow measurements compared with submerged-flow measurements. Using the unified discharge parameters, the mean standard deviation for all of the flumes was 2.1 percent for free flow and 6.5 percent for submerged flow."],"dc:identifier":["https://digitalcommons.usu.edu/etd/7369"],"dc:identifier.doi":["https://doi.org/10.26076/0ef4-394e"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["cutthroat flume","flume","discharge parameters","submerged flow","free flow","Biological Engineering","Other Engineering"],"dc:title":["Analysis of Cutthroat Flume Discharge Ratings"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:57:13Z"}