{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-8775"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-8775","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Reducing Thermal Bridging and Understanding Second-Order Effects in Concrete Sandwich Wall Panels","abstract":"Structural engineers have traditionally detailed structures with structural and fabrication efficiency in mind, but often based on a limited understanding of thermal efficiency. Some connection designs can create significant thermal bridging, leading to unnecessary heat transfer and even premature degradation through condensation. Thermal bridging occurs when heat transfer is given a path through a more conductive material like concrete or steel rather than insulation. Concrete sandwich wall panels (SWP) tend to be highly efficient at preventing heat transfer in the middle of panels, with greatest heat transfer occurring at connections. This project identified thermally efficient details for future SWP construction to reduce heat transfer, lessen environmental impact, and increase sustainability of SWP structures. It can be particularly difficult to avoid thermal bridging at corbel connections, so 12 corbel specimens were created and tested to provide alternative corbel design options for engineers. Nine details were successfully created and are presented. Corbel specimens were modeled using the Beam-Spring Method with good agreement. After validating the Beam-Spring Model, a parametric study investigated effectiveness of the PCI Second Order Analysis and the effect of length, panel stiffness, and wythe configuration on SWP behavior under axial and flexural loads.","abstract_html":"Structural engineers have traditionally detailed structures with structural and fabrication efficiency in mind, but often based on a limited understanding of thermal efficiency. Some connection designs can create significant thermal bridging, leading to unnecessary heat transfer and even premature degradation through condensation. Thermal bridging occurs when heat transfer is given a path through a more conductive material like concrete or steel rather than insulation. Concrete sandwich wall panels (SWP) tend to be highly efficient at preventing heat transfer in the middle of panels, with greatest heat transfer occurring at connections. This project identified thermally efficient details for future SWP construction to reduce heat transfer, lessen environmental impact, and increase sustainability of SWP structures. It can be particularly difficult to avoid thermal bridging at corbel connections, so 12 corbel specimens were created and tested to provide alternative corbel design options for engineers. Nine details were successfully created and are presented. Corbel specimens were modeled using the Beam-Spring Method with good agreement. After validating the Beam-Spring Model, a parametric study investigated effectiveness of the PCI Second Order Analysis and the effect of length, panel stiffness, and wythe configuration on SWP behavior under axial and flexural loads.","abstract_has_math":false,"creators":["Sorensen, Taylor J."],"institution":"Hosted by Utah State University Libraries","degree_name":"Doctor of Philosophy (PhD)","degree_level":"Dissertation","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Marc Maguire","Nick Roberts","Marv Halling"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:51:24Z","subjects":["sandwich wall panel","thermal bridging","heat loss","beam spring model","axial loads","second order effects","thermal detailing","corbels","Civil and Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/046b-c7dd"],"render_values":[{"text":"https://doi.org/10.26076/046b-c7dd","href":"https://doi.org/10.26076/046b-c7dd","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/7642","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/7642","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-8775","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Marc Maguire","Nick Roberts","Marv Halling"]},{"key":"dc:creator","label":"Author","values":["Sorensen, Taylor J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-12-01T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["sandwich wall panel","thermal bridging","heat loss","beam spring model","axial loads","second order effects","thermal detailing","corbels","Civil and Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/7642"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/046b-c7dd"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Structural engineers have traditionally detailed structures with structural and fabrication efficiency in mind, but often based on a limited understanding of thermal efficiency. Some connection designs can create significant thermal bridging, leading to unnecessary heat transfer and even premature degradation through condensation. Thermal bridging occurs when heat transfer is given a path through a more conductive material like concrete or steel rather than insulation. Concrete sandwich wall panels (SWP) tend to be highly efficient at preventing heat transfer in the middle of panels, with greatest heat transfer occurring at connections. This project identified thermally efficient details for future SWP construction to reduce heat transfer, lessen environmental impact, and increase sustainability of SWP structures. It can be particularly difficult to avoid thermal bridging at corbel connections, so 12 corbel specimens were created and tested to provide alternative corbel design options for engineers. Nine details were successfully created and are presented. Corbel specimens were modeled using the Beam-Spring Method with good agreement. After validating the Beam-Spring Model, a parametric study investigated effectiveness of the PCI Second Order Analysis and the effect of length, panel stiffness, and wythe configuration on SWP behavior under axial and flexural loads."]},{"key":"dc:title","label":"Title","values":["Reducing Thermal Bridging and Understanding Second-Order Effects in Concrete Sandwich Wall Panels"]}]}],"canonical_facts":{"dc:contributor":["Marc Maguire","Nick Roberts","Marv Halling"],"dc:creator":["Sorensen, Taylor J."],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2019-12-01T08:00:00Z"],"dc:description.abstract":["Structural engineers have traditionally detailed structures with structural and fabrication efficiency in mind, but often based on a limited understanding of thermal efficiency. Some connection designs can create significant thermal bridging, leading to unnecessary heat transfer and even premature degradation through condensation. Thermal bridging occurs when heat transfer is given a path through a more conductive material like concrete or steel rather than insulation. Concrete sandwich wall panels (SWP) tend to be highly efficient at preventing heat transfer in the middle of panels, with greatest heat transfer occurring at connections. This project identified thermally efficient details for future SWP construction to reduce heat transfer, lessen environmental impact, and increase sustainability of SWP structures. It can be particularly difficult to avoid thermal bridging at corbel connections, so 12 corbel specimens were created and tested to provide alternative corbel design options for engineers. Nine details were successfully created and are presented. Corbel specimens were modeled using the Beam-Spring Method with good agreement. After validating the Beam-Spring Model, a parametric study investigated effectiveness of the PCI Second Order Analysis and the effect of length, panel stiffness, and wythe configuration on SWP behavior under axial and flexural loads."],"dc:identifier":["https://digitalcommons.usu.edu/etd/7642"],"dc:identifier.doi":["https://doi.org/10.26076/046b-c7dd"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["sandwich wall panel","thermal bridging","heat loss","beam spring model","axial loads","second order effects","thermal detailing","corbels","Civil and Environmental Engineering"],"dc:title":["Reducing Thermal Bridging and Understanding Second-Order Effects in Concrete Sandwich Wall Panels"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy (PhD)"]},"updated_at":"2026-11-19T08:51:24Z"}