{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-9200"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-9200","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Finite Element and Pullout Test Performance of Welded Wire Mats","abstract":"This paper reports on the pullout test performance of welded-wire reinforcing mats. A 126-foot high mechanically stabilized earth wall was constructed at Kennecott Utah Copper. In the lower half of the wall, single lengths of 50-foot long welded-wire mats were used. In the top half of the wall, two lengths of 50-foot mats were overlapped 10 feet to create 90-foot mats. This 10-foot \"lap zone\" was investigated in this study. The finite element program Plaxis was used to investigate several pullout test parameters: overburden pressure, gap width, boundary effects, and horizontal spacing of transverse elements from the pullout box face. Physical pullout tests were performed in a scale pullout box to compare test configurations with single and multiple layers of mats, and test configurations with single and multiple lap zones. Finally, a Plaxis model of the scale pullout box was created to compare the finite element and pullout test results.","abstract_html":"This paper reports on the pullout test performance of welded-wire reinforcing mats. A 126-foot high mechanically stabilized earth wall was constructed at Kennecott Utah Copper. In the lower half of the wall, single lengths of 50-foot long welded-wire mats were used. In the top half of the wall, two lengths of 50-foot mats were overlapped 10 feet to create 90-foot mats. This 10-foot &quot;lap zone&quot; was investigated in this study. The finite element program Plaxis was used to investigate several pullout test parameters: overburden pressure, gap width, boundary effects, and horizontal spacing of transverse elements from the pullout box face. Physical pullout tests were performed in a scale pullout box to compare test configurations with single and multiple layers of mats, and test configurations with single and multiple lap zones. Finally, a Plaxis model of the scale pullout box was created to compare the finite element and pullout test results.","abstract_has_math":false,"creators":["Conder, Bradley C."],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["James A. Bay","Loren R. Anderson","Joseph A. Caliendo"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:52:04Z","subjects":["finite element","pullout test","welding","wire mats","Civil and Environmental Engineering","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/98ae-da6a"],"render_values":[{"text":"https://doi.org/10.26076/98ae-da6a","href":"https://doi.org/10.26076/98ae-da6a","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/8058","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/8058","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-9200","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["James A. Bay","Loren R. Anderson","Joseph A. Caliendo"]},{"key":"dc:creator","label":"Author","values":["Conder, Bradley C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2002-05-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["finite element","pullout test","welding","wire mats","Civil and Environmental Engineering","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/8058"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/98ae-da6a"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This paper reports on the pullout test performance of welded-wire reinforcing mats. A 126-foot high mechanically stabilized earth wall was constructed at Kennecott Utah Copper. In the lower half of the wall, single lengths of 50-foot long welded-wire mats were used. In the top half of the wall, two lengths of 50-foot mats were overlapped 10 feet to create 90-foot mats. This 10-foot \"lap zone\" was investigated in this study. The finite element program Plaxis was used to investigate several pullout test parameters: overburden pressure, gap width, boundary effects, and horizontal spacing of transverse elements from the pullout box face. Physical pullout tests were performed in a scale pullout box to compare test configurations with single and multiple layers of mats, and test configurations with single and multiple lap zones. Finally, a Plaxis model of the scale pullout box was created to compare the finite element and pullout test results."]},{"key":"dc:title","label":"Title","values":["Finite Element and Pullout Test Performance of Welded Wire Mats"]}]}],"canonical_facts":{"dc:contributor":["James A. Bay","Loren R. Anderson","Joseph A. Caliendo"],"dc:creator":["Conder, Bradley C."],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2002-05-01T07:00:00Z"],"dc:description.abstract":["This paper reports on the pullout test performance of welded-wire reinforcing mats. A 126-foot high mechanically stabilized earth wall was constructed at Kennecott Utah Copper. In the lower half of the wall, single lengths of 50-foot long welded-wire mats were used. In the top half of the wall, two lengths of 50-foot mats were overlapped 10 feet to create 90-foot mats. This 10-foot \"lap zone\" was investigated in this study. The finite element program Plaxis was used to investigate several pullout test parameters: overburden pressure, gap width, boundary effects, and horizontal spacing of transverse elements from the pullout box face. Physical pullout tests were performed in a scale pullout box to compare test configurations with single and multiple layers of mats, and test configurations with single and multiple lap zones. Finally, a Plaxis model of the scale pullout box was created to compare the finite element and pullout test results."],"dc:identifier":["https://digitalcommons.usu.edu/etd/8058"],"dc:identifier.doi":["https://doi.org/10.26076/98ae-da6a"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["finite element","pullout test","welding","wire mats","Civil and Environmental Engineering","Engineering"],"dc:title":["Finite Element and Pullout Test Performance of Welded Wire Mats"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:52:04Z"}