{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd-9292"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd-9292","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Venturi Meter Performance When Installed on the Branch of a Tee Junction with Converging Run Flow","abstract":"Venturi flow meters are often installed downstream of disturbances such as a tee junction, valve, or elbow. In such a case, a laboratory calibration may be needed to measure the Venturi meter’s performance under said limitations so that accurate metering is achieved. However, in some cases, laboratory calibration may not be possible.The purpose of this research was to investigate Computational Fluid Dynamics (CFD) ability to simulate a Venturi meter installed on the branch of a tee junction with converging run flow. This study used CFD to compare against laboratory results to illustrate CFD’s capability as a calibration method. The results of this study were used to develop a procedure to adjust a Venturi meter’s discharge coefficient for a Venturi meter that will be, or already is, installed on the branch of a tee junction with converging run flow.","abstract_html":"Venturi flow meters are often installed downstream of disturbances such as a tee junction, valve, or elbow. In such a case, a laboratory calibration may be needed to measure the Venturi meter’s performance under said limitations so that accurate metering is achieved. However, in some cases, laboratory calibration may not be possible.The purpose of this research was to investigate Computational Fluid Dynamics (CFD) ability to simulate a Venturi meter installed on the branch of a tee junction with converging run flow. This study used CFD to compare against laboratory results to illustrate CFD’s capability as a calibration method. The results of this study were used to develop a procedure to adjust a Venturi meter’s discharge coefficient for a Venturi meter that will be, or already is, installed on the branch of a tee junction with converging run flow.","abstract_has_math":false,"creators":["Naulu, E. Elliot"],"institution":"Hosted by Utah State University Libraries","degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Michael C. Johnson","Zachary B. Sharp","Marv Halling"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:52:35Z","subjects":["Venturi","tee junction","converging flow","CFD","discharge coefficient","Civil and Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/2e49-5467"],"render_values":[{"text":"https://doi.org/10.26076/2e49-5467","href":"https://doi.org/10.26076/2e49-5467","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd/8150","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd/8150","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd-9292","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Michael C. Johnson","Zachary B. Sharp","Marv Halling"]},{"key":"dc:creator","label":"Author","values":["Naulu, E. Elliot"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-08-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Hosted by Utah State University Libraries"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Venturi","tee junction","converging flow","CFD","discharge coefficient","Civil and Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd/8150"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.26076/2e49-5467"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Venturi flow meters are often installed downstream of disturbances such as a tee junction, valve, or elbow. In such a case, a laboratory calibration may be needed to measure the Venturi meter’s performance under said limitations so that accurate metering is achieved. However, in some cases, laboratory calibration may not be possible.The purpose of this research was to investigate Computational Fluid Dynamics (CFD) ability to simulate a Venturi meter installed on the branch of a tee junction with converging run flow. This study used CFD to compare against laboratory results to illustrate CFD’s capability as a calibration method. The results of this study were used to develop a procedure to adjust a Venturi meter’s discharge coefficient for a Venturi meter that will be, or already is, installed on the branch of a tee junction with converging run flow."]},{"key":"dc:title","label":"Title","values":["Venturi Meter Performance When Installed on the Branch of a Tee Junction with Converging Run Flow"]}]}],"canonical_facts":{"dc:contributor":["Michael C. Johnson","Zachary B. Sharp","Marv Halling"],"dc:creator":["Naulu, E. Elliot"],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2021-08-01T07:00:00Z"],"dc:description.abstract":["Venturi flow meters are often installed downstream of disturbances such as a tee junction, valve, or elbow. In such a case, a laboratory calibration may be needed to measure the Venturi meter’s performance under said limitations so that accurate metering is achieved. However, in some cases, laboratory calibration may not be possible.The purpose of this research was to investigate Computational Fluid Dynamics (CFD) ability to simulate a Venturi meter installed on the branch of a tee junction with converging run flow. This study used CFD to compare against laboratory results to illustrate CFD’s capability as a calibration method. The results of this study were used to develop a procedure to adjust a Venturi meter’s discharge coefficient for a Venturi meter that will be, or already is, installed on the branch of a tee junction with converging run flow."],"dc:identifier":["https://digitalcommons.usu.edu/etd/8150"],"dc:identifier.doi":["https://doi.org/10.26076/2e49-5467"],"dc:publisher":["Hosted by Utah State University Libraries"],"dc:subject":["Venturi","tee junction","converging flow","CFD","discharge coefficient","Civil and Environmental Engineering"],"dc:title":["Venturi Meter Performance When Installed on the Branch of a Tee Junction with Converging Run Flow"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:52:35Z"}