{"id":{"repo_id":"utahstate","oai_identifier":"oai:digitalcommons.usu.edu:etd_biology-1612"},"canonical_url":"https://search.ndltd.org/etd/utahstate/oai:digitalcommons.usu.edu:etd_biology-1612","repository":{"repo_id":"utahstate","name":"Utah State University","base_url":"https://digitalcommons.usu.edu/do/oai/"},"display":{"title":"Aerosol Stability of Reovirus","abstract":"Reoviruses type 1 Lang, type 2 Jones and type 3 Dearing were aerosolized with a Collison nebulizer and aged for two and a half hours in an environmentally controlled Dynamic Aerosol Toroid to determine reovirus inactivation rates. Results from this study were used to evaluate reoviruses as indicators of viral aerosol pollution. Reovirus viability was determined at three temperatures (2°C, 14°C and 27°C) and four relative humidities [(RH) 20%, 40%, 60% and 80% RH]. After the aging period potentially infectious viruses (PIV), those with a complete outer capsid, were treated with trypsin and transformed into infectious virus (IV) with an incomplete outer capsid for assay. The immunofluorescent cell count technique was employed for all assays. Decay rates were greater for PIV and IV particles, of all three reovirus serotypes, at mid-range RH than at either high or low RH. Generally, decay rates were greater for IV particles than for PIV particles for the Jones and Dearing serotypes while the opposite was observed for type 1 Lang. Type 1 Lang exhibited the greatest stability with the lowest overall decay rate (0.05%/min) at 2°C and 80% RH. Relative humidity appeared to have the greatest effect on aerosol stability while increased temperatures had less significant effects on decay rates. Reoviruses, especially type 1 Lang PIV and IV particles exhibit superior stability in the airborne state and show considerable promise as indicators for viral aerosol pollution.","abstract_html":"Reoviruses type 1 Lang, type 2 Jones and type 3 Dearing were aerosolized with a Collison nebulizer and aged for two and a half hours in an environmentally controlled Dynamic Aerosol Toroid to determine reovirus inactivation rates. Results from this study were used to evaluate reoviruses as indicators of viral aerosol pollution. Reovirus viability was determined at three temperatures (2°C, 14°C and 27°C) and four relative humidities [(RH) 20%, 40%, 60% and 80% RH]. After the aging period potentially infectious viruses (PIV), those with a complete outer capsid, were treated with trypsin and transformed into infectious virus (IV) with an incomplete outer capsid for assay. The immunofluorescent cell count technique was employed for all assays. Decay rates were greater for PIV and IV particles, of all three reovirus serotypes, at mid-range RH than at either high or low RH. Generally, decay rates were greater for IV particles than for PIV particles for the Jones and Dearing serotypes while the opposite was observed for type 1 Lang. Type 1 Lang exhibited the greatest stability with the lowest overall decay rate (0.05%/min) at 2°C and 80% RH. Relative humidity appeared to have the greatest effect on aerosol stability while increased temperatures had less significant effects on decay rates. Reoviruses, especially type 1 Lang PIV and IV particles exhibit superior stability in the airborne state and show considerable promise as indicators for viral aerosol pollution.","abstract_has_math":false,"creators":["Mohr, Alan Jeff"],"institution":null,"degree_name":"Doctor of Philosophy (PhD)","degree_level":"Dissertation","degree_discipline":"Biology","degree_department":null,"school":null,"contributors":["Rex S. Spendlove","B. B. Barnett","Gene Wooldridge"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T07:12:38Z","subjects":["Reovirus","Dynamic Aerosol Toroid","Collision Nebulizer","Reovirus Inactivation"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usu.edu/etd_biology/516","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usu.edu/etd_biology/516","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Autahstate%3Aoai%3Adigitalcommons.usu.edu%3Aetd_biology-1612","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.usu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usu.edu%3Aetd_biology-1612","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Rex S. Spendlove","B. B. Barnett","Gene Wooldridge"]},{"key":"dc:creator","label":"Author","values":["Mohr, Alan Jeff"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1984-05-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Reovirus","Dynamic Aerosol Toroid","Collision Nebulizer","Reovirus Inactivation"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usu.edu/etd_biology/516"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Reoviruses type 1 Lang, type 2 Jones and type 3 Dearing were aerosolized with a Collison nebulizer and aged for two and a half hours in an environmentally controlled Dynamic Aerosol Toroid to determine reovirus inactivation rates. Results from this study were used to evaluate reoviruses as indicators of viral aerosol pollution. Reovirus viability was determined at three temperatures (2°C, 14°C and 27°C) and four relative humidities [(RH) 20%, 40%, 60% and 80% RH]. After the aging period potentially infectious viruses (PIV), those with a complete outer capsid, were treated with trypsin and transformed into infectious virus (IV) with an incomplete outer capsid for assay. The immunofluorescent cell count technique was employed for all assays. Decay rates were greater for PIV and IV particles, of all three reovirus serotypes, at mid-range RH than at either high or low RH. Generally, decay rates were greater for IV particles than for PIV particles for the Jones and Dearing serotypes while the opposite was observed for type 1 Lang. Type 1 Lang exhibited the greatest stability with the lowest overall decay rate (0.05%/min) at 2°C and 80% RH. Relative humidity appeared to have the greatest effect on aerosol stability while increased temperatures had less significant effects on decay rates. Reoviruses, especially type 1 Lang PIV and IV particles exhibit superior stability in the airborne state and show considerable promise as indicators for viral aerosol pollution."]},{"key":"dc:title","label":"Title","values":["Aerosol Stability of Reovirus"]}]}],"canonical_facts":{"dc:contributor":["Rex S. Spendlove","B. B. Barnett","Gene Wooldridge"],"dc:creator":["Mohr, Alan Jeff"],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["1984-05-01T07:00:00Z"],"dc:description.abstract":["Reoviruses type 1 Lang, type 2 Jones and type 3 Dearing were aerosolized with a Collison nebulizer and aged for two and a half hours in an environmentally controlled Dynamic Aerosol Toroid to determine reovirus inactivation rates. Results from this study were used to evaluate reoviruses as indicators of viral aerosol pollution. Reovirus viability was determined at three temperatures (2°C, 14°C and 27°C) and four relative humidities [(RH) 20%, 40%, 60% and 80% RH]. After the aging period potentially infectious viruses (PIV), those with a complete outer capsid, were treated with trypsin and transformed into infectious virus (IV) with an incomplete outer capsid for assay. The immunofluorescent cell count technique was employed for all assays. Decay rates were greater for PIV and IV particles, of all three reovirus serotypes, at mid-range RH than at either high or low RH. Generally, decay rates were greater for IV particles than for PIV particles for the Jones and Dearing serotypes while the opposite was observed for type 1 Lang. Type 1 Lang exhibited the greatest stability with the lowest overall decay rate (0.05%/min) at 2°C and 80% RH. Relative humidity appeared to have the greatest effect on aerosol stability while increased temperatures had less significant effects on decay rates. Reoviruses, especially type 1 Lang PIV and IV particles exhibit superior stability in the airborne state and show considerable promise as indicators for viral aerosol pollution."],"dc:identifier":["https://digitalcommons.usu.edu/etd_biology/516"],"dc:subject":["Reovirus","Dynamic Aerosol Toroid","Collision Nebulizer","Reovirus Inactivation"],"dc:title":["Aerosol Stability of Reovirus"],"thesis:degree_discipline":["Biology"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy (PhD)"]},"updated_at":"2026-11-27T07:12:38Z"}