{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/10141"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/10141","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Efficient similarity-driven emission angle selection for coherent plane-wave compounding","abstract":"Typical ultrafast plane-wave ultrasound imaging involves: 1) insonifying the medium with several plane-wave pulses emitted at different angles by a linear transducer array, 2) sampling the returning echo signals, after each plane-wave emission, with the same transducer array, 3) beamforming the recorded angle-specific raw data frames, and 4) compounding the beamformed data frames over all angles to form a final image. This thesis attempts to address the following question: Given a set of available plane-wave emission angles, which ones should we select for acquisition (i.e., which angle-specific raw data frames should we sample), to achieve adequate image quality at low cost associated with both sampling and computation? We propose a simple similarity-driven angle selection scheme and evaluate its several variants that rely on user-specified similarity measurement thresholds guiding the recursive angle selection process. Our results show that the proposed scheme has a low computational overhead and can yield significant savings in terms of the amount of sampled raw data.","abstract_html":"Typical ultrafast plane-wave ultrasound imaging involves: 1) insonifying the medium with several plane-wave pulses emitted at different angles by a linear transducer array, 2) sampling the returning echo signals, after each plane-wave emission, with the same transducer array, 3) beamforming the recorded angle-specific raw data frames, and 4) compounding the beamformed data frames over all angles to form a final image. This thesis attempts to address the following question: Given a set of available plane-wave emission angles, which ones should we select for acquisition (i.e., which angle-specific raw data frames should we sample), to achieve adequate image quality at low cost associated with both sampling and computation? We propose a simple similarity-driven angle selection scheme and evaluate its several variants that rely on user-specified similarity measurement thresholds guiding the recursive angle selection process. Our results show that the proposed scheme has a low computational overhead and can yield significant savings in terms of the amount of sampled raw data.","abstract_has_math":false,"creators":["Akbar, Haroon Ali"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Rakhmatov, Daler N."],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-10-09","date_published":"2018-10-09","updated_at":"2026-11-19T09:39:52Z","subjects":["Similarity - Driven Angle Selection Using Beamformed Data (SASB)","Similarity - Driven Angle Selection Using Raw Data (SASR)","Ultrasound Image Quality","Delay - and - Sum (DAS) Beamforming","Coherent Plane - Wave Compounding (CPWC)"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1828/10141","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1828/10141","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F10141","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Rakhmatov, Daler N."]},{"key":"dc:creator","label":"Author","values":["Akbar, Haroon Ali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-10-09T21:10:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-10-09T21:10:32Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2018"]},{"key":"dc:date.issued","label":"Date","values":["2018-10-09"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Similarity - Driven Angle Selection Using Beamformed Data (SASB)","Similarity - Driven Angle Selection Using Raw Data (SASR)","Ultrasound Image Quality","Delay - and - Sum (DAS) Beamforming","Coherent Plane - Wave Compounding (CPWC)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/10141"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Typical ultrafast plane-wave ultrasound imaging involves: 1) insonifying the medium with several plane-wave pulses emitted at different angles by a linear transducer array, 2) sampling the returning echo signals, after each plane-wave emission, with the same transducer array, 3) beamforming the recorded angle-specific raw data frames, and 4) compounding the beamformed data frames over all angles to form a final image. This thesis attempts to address the following question: Given a set of available plane-wave emission angles, which ones should we select for acquisition (i.e., which angle-specific raw data frames should we sample), to achieve adequate image quality at low cost associated with both sampling and computation? We propose a simple similarity-driven angle selection scheme and evaluate its several variants that rely on user-specified similarity measurement thresholds guiding the recursive angle selection process. Our results show that the proposed scheme has a low computational overhead and can yield significant savings in terms of the amount of sampled raw data."]},{"key":"dc:description.scholarlevel","label":"Dc Description Scholarlevel","values":["Graduate"]},{"key":"dc:title","label":"Title","values":["Efficient similarity-driven emission angle selection for coherent plane-wave compounding"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Rakhmatov, Daler N."],"dc:creator":["Akbar, Haroon Ali"],"dc:date.accessioned":["2018-10-09T21:10:32Z"],"dc:date.available":["2018-10-09T21:10:32Z"],"dc:date.copyright":["2018"],"dc:date.issued":["2018-10-09"],"dc:description.abstract":["Typical ultrafast plane-wave ultrasound imaging involves: 1) insonifying the medium with several plane-wave pulses emitted at different angles by a linear transducer array, 2) sampling the returning echo signals, after each plane-wave emission, with the same transducer array, 3) beamforming the recorded angle-specific raw data frames, and 4) compounding the beamformed data frames over all angles to form a final image. This thesis attempts to address the following question: Given a set of available plane-wave emission angles, which ones should we select for acquisition (i.e., which angle-specific raw data frames should we sample), to achieve adequate image quality at low cost associated with both sampling and computation? We propose a simple similarity-driven angle selection scheme and evaluate its several variants that rely on user-specified similarity measurement thresholds guiding the recursive angle selection process. Our results show that the proposed scheme has a low computational overhead and can yield significant savings in terms of the amount of sampled raw data."],"dc:description.scholarlevel":["Graduate"],"dc:identifier.uri":["http://hdl.handle.net/1828/10141"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["Similarity - Driven Angle Selection Using Beamformed Data (SASB)","Similarity - Driven Angle Selection Using Raw Data (SASR)","Ultrasound Image Quality","Delay - and - Sum (DAS) Beamforming","Coherent Plane - Wave Compounding (CPWC)"],"dc:title":["Efficient similarity-driven emission angle selection for coherent plane-wave compounding"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Electrical and Computer Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:39:52Z"}