{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/11658"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/11658","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Fixed-point hardware design for CPWC image reconstruction","abstract":"Coherent plane-wave compounding (CPWC) ultrasonography is an important imaging modality that allows for very high frame rates. During CPWC image reconstruction, computationally expensive delay-and-sum beamforming can be replaced by faster Fourier-domain remapping. The thesis deals with the MATLAB and hardware implementation of one of the recently proposed Fourier-domain CPWC reconstruction methods, namely, plane-wave (PW) Stolt's migration algorithm. We first present the floating- and fixed-point implementations of the said migration algorithm in MATLAB, and then perform quantitative evaluation of the reconstruction results, showing that it is feasible to obtain high-quality compounded images using hardware-oriented scaled fixed-point calculations, as opposed to more expensive software-oriented floating-point arithmetic. We also generate Xilinx FPGA-based implementations of both floating- and fixed-point MATLAB-based algorithms, using a high-level synthesis (HLS) design flow that collaboratively employs MATLAB Coder and Vivado HLS tool. MATLAB Coder can automatically convert a MATLAB code into a C program, while Vivado HLS can convert the resulting C program into a synthesizable Verilog/VHDL description. Results show that our fixed-point FPGA implementation is more resource and power efficient and can also operate at a higher clock frequency compared to its floating-point counterpart.","abstract_html":"Coherent plane-wave compounding (CPWC) ultrasonography is an important imaging modality that allows for very high frame rates. During CPWC image reconstruction, computationally expensive delay-and-sum beamforming can be replaced by faster Fourier-domain remapping. The thesis deals with the MATLAB and hardware implementation of one of the recently proposed Fourier-domain CPWC reconstruction methods, namely, plane-wave (PW) Stolt&#x27;s migration algorithm. We first present the floating- and fixed-point implementations of the said migration algorithm in MATLAB, and then perform quantitative evaluation of the reconstruction results, showing that it is feasible to obtain high-quality compounded images using hardware-oriented scaled fixed-point calculations, as opposed to more expensive software-oriented floating-point arithmetic. We also generate Xilinx FPGA-based implementations of both floating- and fixed-point MATLAB-based algorithms, using a high-level synthesis (HLS) design flow that collaboratively employs MATLAB Coder and Vivado HLS tool. MATLAB Coder can automatically convert a MATLAB code into a C program, while Vivado HLS can convert the resulting C program into a synthesizable Verilog/VHDL description. Results show that our fixed-point FPGA implementation is more resource and power efficient and can also operate at a higher clock frequency compared to its floating-point counterpart.","abstract_has_math":false,"creators":["Shi, Ji"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Rakhmatov, Daler N."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-03-27","date_published":"2020-03-27","updated_at":"2026-11-19T09:39:14Z","subjects":["Plane-wave ultrasound imaging","Fixed-point computation","FPGA implementation"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["J. Shi and D. Rakhmatov,“Fixed-point CPWC ultrasound image reconstruction,”in 2019 IEEE International Ultrasonics Symposium (IUS). IEEE, 2019, pp. 1282–1285."],"render_values":[{"text":"J. Shi and D. Rakhmatov,“Fixed-point CPWC ultrasound image reconstruction,”in 2019 IEEE International Ultrasonics Symposium (IUS). IEEE, 2019, pp. 1282–1285.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1828/11658","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1828/11658","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auvic%3Aoai%3Adspace.library.uvic.ca%3A1828%2F11658","prefix":"oai_dc"},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F11658","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Rakhmatov, Daler N."]},{"key":"dc:creator","label":"Author","values":["Shi, Ji"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-03-28T01:13:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-03-28T01:13:12Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020"]},{"key":"dc:date.issued","label":"Date","values":["2020-03-27"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Plane-wave ultrasound imaging","Fixed-point computation","FPGA implementation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["J. Shi and D. Rakhmatov,“Fixed-point CPWC ultrasound image reconstruction,”in 2019 IEEE International Ultrasonics Symposium (IUS). IEEE, 2019, pp. 1282–1285."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/11658"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Coherent plane-wave compounding (CPWC) ultrasonography is an important imaging modality that allows for very high frame rates. During CPWC image reconstruction, computationally expensive delay-and-sum beamforming can be replaced by faster Fourier-domain remapping. The thesis deals with the MATLAB and hardware implementation of one of the recently proposed Fourier-domain CPWC reconstruction methods, namely, plane-wave (PW) Stolt's migration algorithm. We first present the floating- and fixed-point implementations of the said migration algorithm in MATLAB, and then perform quantitative evaluation of the reconstruction results, showing that it is feasible to obtain high-quality compounded images using hardware-oriented scaled fixed-point calculations, as opposed to more expensive software-oriented floating-point arithmetic. We also generate Xilinx FPGA-based implementations of both floating- and fixed-point MATLAB-based algorithms, using a high-level synthesis (HLS) design flow that collaboratively employs MATLAB Coder and Vivado HLS tool. MATLAB Coder can automatically convert a MATLAB code into a C program, while Vivado HLS can convert the resulting C program into a synthesizable Verilog/VHDL description. Results show that our fixed-point FPGA implementation is more resource and power efficient and can also operate at a higher clock frequency compared to its floating-point counterpart."]},{"key":"dc:description.scholarlevel","label":"Dc Description Scholarlevel","values":["Graduate"]},{"key":"dc:title","label":"Title","values":["Fixed-point hardware design for CPWC image reconstruction"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Rakhmatov, Daler N."],"dc:creator":["Shi, Ji"],"dc:date.accessioned":["2020-03-28T01:13:12Z"],"dc:date.available":["2020-03-28T01:13:12Z"],"dc:date.copyright":["2020"],"dc:date.issued":["2020-03-27"],"dc:description.abstract":["Coherent plane-wave compounding (CPWC) ultrasonography is an important imaging modality that allows for very high frame rates. During CPWC image reconstruction, computationally expensive delay-and-sum beamforming can be replaced by faster Fourier-domain remapping. The thesis deals with the MATLAB and hardware implementation of one of the recently proposed Fourier-domain CPWC reconstruction methods, namely, plane-wave (PW) Stolt's migration algorithm. We first present the floating- and fixed-point implementations of the said migration algorithm in MATLAB, and then perform quantitative evaluation of the reconstruction results, showing that it is feasible to obtain high-quality compounded images using hardware-oriented scaled fixed-point calculations, as opposed to more expensive software-oriented floating-point arithmetic. We also generate Xilinx FPGA-based implementations of both floating- and fixed-point MATLAB-based algorithms, using a high-level synthesis (HLS) design flow that collaboratively employs MATLAB Coder and Vivado HLS tool. MATLAB Coder can automatically convert a MATLAB code into a C program, while Vivado HLS can convert the resulting C program into a synthesizable Verilog/VHDL description. Results show that our fixed-point FPGA implementation is more resource and power efficient and can also operate at a higher clock frequency compared to its floating-point counterpart."],"dc:description.scholarlevel":["Graduate"],"dc:identifier.citation":["J. Shi and D. Rakhmatov,“Fixed-point CPWC ultrasound image reconstruction,”in 2019 IEEE International Ultrasonics Symposium (IUS). IEEE, 2019, pp. 1282–1285."],"dc:identifier.uri":["http://hdl.handle.net/1828/11658"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["Plane-wave ultrasound imaging","Fixed-point computation","FPGA implementation"],"dc:title":["Fixed-point hardware design for CPWC image reconstruction"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Electrical and Computer Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:39:14Z"}