{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/13797"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/13797","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Hydrologic and water quality performance of bioretention cells during plant senescence","abstract":"Bioretention cells (also known as rain gardens) are a Low Impact Development (LID) method for sustainable stormwater management. An increasingly popular form of urban stormwater infrastructure, bioretention cells use an engineered, vegetated-soil-system to both reduce quantity and enhance quality of stormwater. The ability of bioretention systems to remove common pollutants from urban stormwater runoff, and reduce runoff volume through evapotranspiration, in a temperature climate during plant senescence were assessed in this full scale field-based study. Stormwater run-off simulations were conducted for 5-, 10-, and 25-year return period storm events at a field site in Victoria, British Columbia, Canada. Tests were run on both, a vegetated cell planted with a mix of Betula nigra, Betula nana, and Salix lutea, and a control cell with turfgrass. Influent and effluent field parameters were recorded for pH and dissolved oxygen (DO), in addition to lab analyses conducted to quantify COD, TN, TON, TP, ortho-phosphate, and TSS removal from the stormwater. Water quality and hydrologic performance were results were compared between the vegetated and control cell using a Wilcoxon Signed Rank Test. In addition, hydrologic results were correlated with daily Evapotranspiration (ET) and meteorological station data using Spearman’s Rho Correlation. The vegetated cells were more effective (p value < 0.05) at retention of water volume, DO, COD, and orthophosphate, when compared to the control. Strong correlations (p value < 0.05) were found between the retention of water volume, and each of ET, maximum temperature, average temperature, minimum temperature, and average wind, for only the vegetated cells.","abstract_html":"Bioretention cells (also known as rain gardens) are a Low Impact Development (LID) method for sustainable stormwater management. An increasingly popular form of urban stormwater infrastructure, bioretention cells use an engineered, vegetated-soil-system to both reduce quantity and enhance quality of stormwater. The ability of bioretention systems to remove common pollutants from urban stormwater runoff, and reduce runoff volume through evapotranspiration, in a temperature climate during plant senescence were assessed in this full scale field-based study. Stormwater run-off simulations were conducted for 5-, 10-, and 25-year return period storm events at a field site in Victoria, British Columbia, Canada. Tests were run on both, a vegetated cell planted with a mix of Betula nigra, Betula nana, and Salix lutea, and a control cell with turfgrass. Influent and effluent field parameters were recorded for pH and dissolved oxygen (DO), in addition to lab analyses conducted to quantify COD, TN, TON, TP, ortho-phosphate, and TSS removal from the stormwater. Water quality and hydrologic performance were results were compared between the vegetated and control cell using a Wilcoxon Signed Rank Test. In addition, hydrologic results were correlated with daily Evapotranspiration (ET) and meteorological station data using Spearman’s Rho Correlation. The vegetated cells were more effective (p value &lt; 0.05) at retention of water volume, DO, COD, and orthophosphate, when compared to the control. Strong correlations (p value &lt; 0.05) were found between the retention of water volume, and each of ET, maximum temperature, average temperature, minimum temperature, and average wind, for only the vegetated cells.","abstract_has_math":false,"creators":["Dhami, Jessica"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":["Valeo, Caterina"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-03-11","date_published":"2022-03-11","updated_at":"2026-11-19T09:41:56Z","subjects":["Stormwater","Low Impact Development","Green Rainwater Infrastructure"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1828/13797","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1828/13797","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F13797","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Valeo, Caterina"]},{"key":"dc:creator","label":"Author","values":["Dhami, Jessica"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-03-12T00:34:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-03-12T00:34:15Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2022"]},{"key":"dc:date.issued","label":"Date","values":["2022-03-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Stormwater","Low Impact Development","Green Rainwater Infrastructure"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/13797"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Bioretention cells (also known as rain gardens) are a Low Impact Development (LID) method for sustainable stormwater management. An increasingly popular form of urban stormwater infrastructure, bioretention cells use an engineered, vegetated-soil-system to both reduce quantity and enhance quality of stormwater. The ability of bioretention systems to remove common pollutants from urban stormwater runoff, and reduce runoff volume through evapotranspiration, in a temperature climate during plant senescence were assessed in this full scale field-based study. Stormwater run-off simulations were conducted for 5-, 10-, and 25-year return period storm events at a field site in Victoria, British Columbia, Canada. Tests were run on both, a vegetated cell planted with a mix of Betula nigra, Betula nana, and Salix lutea, and a control cell with turfgrass. Influent and effluent field parameters were recorded for pH and dissolved oxygen (DO), in addition to lab analyses conducted to quantify COD, TN, TON, TP, ortho-phosphate, and TSS removal from the stormwater. Water quality and hydrologic performance were results were compared between the vegetated and control cell using a Wilcoxon Signed Rank Test. In addition, hydrologic results were correlated with daily Evapotranspiration (ET) and meteorological station data using Spearman’s Rho Correlation. The vegetated cells were more effective (p value < 0.05) at retention of water volume, DO, COD, and orthophosphate, when compared to the control. Strong correlations (p value < 0.05) were found between the retention of water volume, and each of ET, maximum temperature, average temperature, minimum temperature, and average wind, for only the vegetated cells."]},{"key":"dc:description.scholarlevel","label":"Dc Description Scholarlevel","values":["Graduate"]},{"key":"dc:title","label":"Title","values":["Hydrologic and water quality performance of bioretention cells during plant senescence"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Valeo, Caterina"],"dc:creator":["Dhami, Jessica"],"dc:date.accessioned":["2022-03-12T00:34:15Z"],"dc:date.available":["2022-03-12T00:34:15Z"],"dc:date.copyright":["2022"],"dc:date.issued":["2022-03-11"],"dc:description.abstract":["Bioretention cells (also known as rain gardens) are a Low Impact Development (LID) method for sustainable stormwater management. An increasingly popular form of urban stormwater infrastructure, bioretention cells use an engineered, vegetated-soil-system to both reduce quantity and enhance quality of stormwater. The ability of bioretention systems to remove common pollutants from urban stormwater runoff, and reduce runoff volume through evapotranspiration, in a temperature climate during plant senescence were assessed in this full scale field-based study. Stormwater run-off simulations were conducted for 5-, 10-, and 25-year return period storm events at a field site in Victoria, British Columbia, Canada. Tests were run on both, a vegetated cell planted with a mix of Betula nigra, Betula nana, and Salix lutea, and a control cell with turfgrass. Influent and effluent field parameters were recorded for pH and dissolved oxygen (DO), in addition to lab analyses conducted to quantify COD, TN, TON, TP, ortho-phosphate, and TSS removal from the stormwater. Water quality and hydrologic performance were results were compared between the vegetated and control cell using a Wilcoxon Signed Rank Test. In addition, hydrologic results were correlated with daily Evapotranspiration (ET) and meteorological station data using Spearman’s Rho Correlation. The vegetated cells were more effective (p value < 0.05) at retention of water volume, DO, COD, and orthophosphate, when compared to the control. Strong correlations (p value < 0.05) were found between the retention of water volume, and each of ET, maximum temperature, average temperature, minimum temperature, and average wind, for only the vegetated cells."],"dc:description.scholarlevel":["Graduate"],"dc:identifier.uri":["http://hdl.handle.net/1828/13797"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["Stormwater","Low Impact Development","Green Rainwater Infrastructure"],"dc:title":["Hydrologic and water quality performance of bioretention cells during plant senescence"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Mechanical Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:41:56Z"}