{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/15165"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/15165","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Stress concentration factors for truss-end hollow structural section connections","abstract":"Design of end connections in a welded hollow structural section (HSS) truss has been a practical problem encountered by structural engineers since current design standards do not include definitive recommendations. For fatigue design, formulae in current design guidelines [for calculation of stress concentration factors (SCFs)] cater to: (i) unreinforced connections, with (ii) sufficient chord continuity beyond the connection on both sides. Existing formulae in CIDECT Design Guide 8 (DG8) for regular connections were shown to be inaccurate for calculation of SCFs for truss-end HSS T- and X-connections. In Chapter 1, a numerical finite element (FE) investigation to determine SCFs for circular hollow section (CHS)-to-CHS X-connections near an open chord end under branch axial loading is presented. Previous large-scale experiments were used to validate FE models, and a parametric study was performed. The parametric study consists of 240 models with variations in chord slenderness (2γ), branch-to-chord diameter ratio (β), branch-to-chord thickness ratio (τ), and chord end distance (e) on one side of the of the connection. Extrapolating existing formulae to predict “end-distance effects” on SCFs at these locations in CHS-to-CHS X-connections, from CIDECT Design Guide 8, were shown to be inaccurate. In Chapter 2, by reinforcing the previous 240 CHS models using a chord-end cap plate and repeating the numerical FE analysis, the SCFs for CHS-to-CHS X-connections near an open chord end was examined. Existing SCF formulae in CIDECT Design Guide 8 were shown to be inaccurate if applied to cap plate-reinforced end connections. Chapter 3 and 4 is a continuation of development of design formulae for truss-end rectangular hollow section (RHS)-to-RHS and CHS-to-CHS connections under in plane bending loading, respectively. Upon validation using the experimental data from previous chapters, a comprehensive parametric study was performed. For this purpose, a total of 448 finite element RHS models including 336 stepped T-connections and 112 matched T-connections (Chapter 3), and 1120 finite element CHS models including 896 stepped T- and X-connections and 224 matched T- and X-connections were created (Chapter 4). Similar to the previous chapters, it was shown that existing formulae in CIDECT Design Guide 8 were unsuitable for the calculation of SCFs for truss-end RHS-to-RHS and CHS-to-CHS moment connections. Finally, SCF correction coefficients (ψ) and parametric formulae to estimate ψ were derived for each chapters.","abstract_html":"Design of end connections in a welded hollow structural section (HSS) truss has been a practical problem encountered by structural engineers since current design standards do not include definitive recommendations. For fatigue design, formulae in current design guidelines [for calculation of stress concentration factors (SCFs)] cater to: (i) unreinforced connections, with (ii) sufficient chord continuity beyond the connection on both sides. Existing formulae in CIDECT Design Guide 8 (DG8) for regular connections were shown to be inaccurate for calculation of SCFs for truss-end HSS T- and X-connections. In Chapter 1, a numerical finite element (FE) investigation to determine SCFs for circular hollow section (CHS)-to-CHS X-connections near an open chord end under branch axial loading is presented. Previous large-scale experiments were used to validate FE models, and a parametric study was performed. The parametric study consists of 240 models with variations in chord slenderness (2γ), branch-to-chord diameter ratio (β), branch-to-chord thickness ratio (τ), and chord end distance (e) on one side of the of the connection. Extrapolating existing formulae to predict “end-distance effects” on SCFs at these locations in CHS-to-CHS X-connections, from CIDECT Design Guide 8, were shown to be inaccurate. In Chapter 2, by reinforcing the previous 240 CHS models using a chord-end cap plate and repeating the numerical FE analysis, the SCFs for CHS-to-CHS X-connections near an open chord end was examined. Existing SCF formulae in CIDECT Design Guide 8 were shown to be inaccurate if applied to cap plate-reinforced end connections. Chapter 3 and 4 is a continuation of development of design formulae for truss-end rectangular hollow section (RHS)-to-RHS and CHS-to-CHS connections under in plane bending loading, respectively. Upon validation using the experimental data from previous chapters, a comprehensive parametric study was performed. For this purpose, a total of 448 finite element RHS models including 336 stepped T-connections and 112 matched T-connections (Chapter 3), and 1120 finite element CHS models including 896 stepped T- and X-connections and 224 matched T- and X-connections were created (Chapter 4). Similar to the previous chapters, it was shown that existing formulae in CIDECT Design Guide 8 were unsuitable for the calculation of SCFs for truss-end RHS-to-RHS and CHS-to-CHS moment connections. Finally, SCF correction coefficients (ψ) and parametric formulae to estimate ψ were derived for each chapters.","abstract_has_math":false,"creators":["Ziaeinejad, Ali"],"institution":null,"degree_name":null,"degree_level":"Doctor of Philosophy Ph.D.","degree_discipline":null,"degree_department":"Department of Civil Engineering","school":null,"contributors":[],"advisors":["Sun, Min"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-06-14","date_published":"2023-06-14","updated_at":"2026-11-19T09:43:00Z","subjects":["End-distance effects","Stress concentration factors","Fatigue design","Cap plates","Circular hollow sections","Rectangular hollow sections","moment connections"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ziaeinejad, A., Sun, M., Tousignant, K., (2020). Circular hollow section X-connections near an open chord end: stress concentration factors. Journal of Constructional Steel Research 106454.","Sun, M., Tousignant, K., Ziaeinejad, A., Daneshvar, S., (2021). Chord-end RHS-to-RHS and CHS-to-CHS X-connections with rigid cap plates: Stress concentration factors. Journal of Constructional Steel Research, 179-106567."],"render_values":[{"text":"Ziaeinejad, A., Sun, M., Tousignant, K., (2020). Circular hollow section X-connections near an open chord end: stress concentration factors. Journal of Constructional Steel Research 106454.","href":null,"code":true},{"text":"Sun, M., Tousignant, K., Ziaeinejad, A., Daneshvar, S., (2021). Chord-end RHS-to-RHS and CHS-to-CHS X-connections with rigid cap plates: Stress concentration factors. Journal of Constructional Steel Research, 179-106567.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1828/15165","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1828/15165","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auvic%3Aoai%3Adspace.library.uvic.ca%3A1828%2F15165","prefix":"oai_dc"},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F15165","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Sun, Min"]},{"key":"dc:creator","label":"Author","values":["Ziaeinejad, Ali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-06-14T19:47:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-06-14T19:47:54Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023"]},{"key":"dc:date.issued","label":"Date","values":["2023-06-14"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy Ph.D."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["End-distance effects","Stress concentration factors","Fatigue design","Cap plates","Circular hollow sections","Rectangular hollow sections","moment connections"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ziaeinejad, A., Sun, M., Tousignant, K., (2020). Circular hollow section X-connections near an open chord end: stress concentration factors. Journal of Constructional Steel Research 106454.","Sun, M., Tousignant, K., Ziaeinejad, A., Daneshvar, S., (2021). Chord-end RHS-to-RHS and CHS-to-CHS X-connections with rigid cap plates: Stress concentration factors. Journal of Constructional Steel Research, 179-106567."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/15165"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Design of end connections in a welded hollow structural section (HSS) truss has been a practical problem encountered by structural engineers since current design standards do not include definitive recommendations. For fatigue design, formulae in current design guidelines [for calculation of stress concentration factors (SCFs)] cater to: (i) unreinforced connections, with (ii) sufficient chord continuity beyond the connection on both sides. Existing formulae in CIDECT Design Guide 8 (DG8) for regular connections were shown to be inaccurate for calculation of SCFs for truss-end HSS T- and X-connections. In Chapter 1, a numerical finite element (FE) investigation to determine SCFs for circular hollow section (CHS)-to-CHS X-connections near an open chord end under branch axial loading is presented. Previous large-scale experiments were used to validate FE models, and a parametric study was performed. The parametric study consists of 240 models with variations in chord slenderness (2γ), branch-to-chord diameter ratio (β), branch-to-chord thickness ratio (τ), and chord end distance (e) on one side of the of the connection. Extrapolating existing formulae to predict “end-distance effects” on SCFs at these locations in CHS-to-CHS X-connections, from CIDECT Design Guide 8, were shown to be inaccurate. In Chapter 2, by reinforcing the previous 240 CHS models using a chord-end cap plate and repeating the numerical FE analysis, the SCFs for CHS-to-CHS X-connections near an open chord end was examined. Existing SCF formulae in CIDECT Design Guide 8 were shown to be inaccurate if applied to cap plate-reinforced end connections. Chapter 3 and 4 is a continuation of development of design formulae for truss-end rectangular hollow section (RHS)-to-RHS and CHS-to-CHS connections under in plane bending loading, respectively. Upon validation using the experimental data from previous chapters, a comprehensive parametric study was performed. For this purpose, a total of 448 finite element RHS models including 336 stepped T-connections and 112 matched T-connections (Chapter 3), and 1120 finite element CHS models including 896 stepped T- and X-connections and 224 matched T- and X-connections were created (Chapter 4). Similar to the previous chapters, it was shown that existing formulae in CIDECT Design Guide 8 were unsuitable for the calculation of SCFs for truss-end RHS-to-RHS and CHS-to-CHS moment connections. Finally, SCF correction coefficients (ψ) and parametric formulae to estimate ψ were derived for each chapters."]},{"key":"dc:description.scholarlevel","label":"Dc Description Scholarlevel","values":["Graduate"]},{"key":"dc:title","label":"Title","values":["Stress concentration factors for truss-end hollow structural section connections"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Sun, Min"],"dc:creator":["Ziaeinejad, Ali"],"dc:date.accessioned":["2023-06-14T19:47:54Z"],"dc:date.available":["2023-06-14T19:47:54Z"],"dc:date.copyright":["2023"],"dc:date.issued":["2023-06-14"],"dc:description.abstract":["Design of end connections in a welded hollow structural section (HSS) truss has been a practical problem encountered by structural engineers since current design standards do not include definitive recommendations. For fatigue design, formulae in current design guidelines [for calculation of stress concentration factors (SCFs)] cater to: (i) unreinforced connections, with (ii) sufficient chord continuity beyond the connection on both sides. Existing formulae in CIDECT Design Guide 8 (DG8) for regular connections were shown to be inaccurate for calculation of SCFs for truss-end HSS T- and X-connections. In Chapter 1, a numerical finite element (FE) investigation to determine SCFs for circular hollow section (CHS)-to-CHS X-connections near an open chord end under branch axial loading is presented. Previous large-scale experiments were used to validate FE models, and a parametric study was performed. The parametric study consists of 240 models with variations in chord slenderness (2γ), branch-to-chord diameter ratio (β), branch-to-chord thickness ratio (τ), and chord end distance (e) on one side of the of the connection. Extrapolating existing formulae to predict “end-distance effects” on SCFs at these locations in CHS-to-CHS X-connections, from CIDECT Design Guide 8, were shown to be inaccurate. In Chapter 2, by reinforcing the previous 240 CHS models using a chord-end cap plate and repeating the numerical FE analysis, the SCFs for CHS-to-CHS X-connections near an open chord end was examined. Existing SCF formulae in CIDECT Design Guide 8 were shown to be inaccurate if applied to cap plate-reinforced end connections. Chapter 3 and 4 is a continuation of development of design formulae for truss-end rectangular hollow section (RHS)-to-RHS and CHS-to-CHS connections under in plane bending loading, respectively. Upon validation using the experimental data from previous chapters, a comprehensive parametric study was performed. For this purpose, a total of 448 finite element RHS models including 336 stepped T-connections and 112 matched T-connections (Chapter 3), and 1120 finite element CHS models including 896 stepped T- and X-connections and 224 matched T- and X-connections were created (Chapter 4). Similar to the previous chapters, it was shown that existing formulae in CIDECT Design Guide 8 were unsuitable for the calculation of SCFs for truss-end RHS-to-RHS and CHS-to-CHS moment connections. Finally, SCF correction coefficients (ψ) and parametric formulae to estimate ψ were derived for each chapters."],"dc:description.scholarlevel":["Graduate"],"dc:identifier.citation":["Ziaeinejad, A., Sun, M., Tousignant, K., (2020). Circular hollow section X-connections near an open chord end: stress concentration factors. Journal of Constructional Steel Research 106454.","Sun, M., Tousignant, K., Ziaeinejad, A., Daneshvar, S., (2021). Chord-end RHS-to-RHS and CHS-to-CHS X-connections with rigid cap plates: Stress concentration factors. Journal of Constructional Steel Research, 179-106567."],"dc:identifier.uri":["http://hdl.handle.net/1828/15165"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["End-distance effects","Stress concentration factors","Fatigue design","Cap plates","Circular hollow sections","Rectangular hollow sections","moment connections"],"dc:title":["Stress concentration factors for truss-end hollow structural section connections"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Civil Engineering"],"thesis:degree_level":["Doctor of Philosophy Ph.D."]},"updated_at":"2026-11-19T09:43:00Z"}