{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/1840"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/1840","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Radio frequency power absorption in a human model with pacemakers in MRI","abstract":"The interactions of the radio frequency (RF) fields in magnetic resonance imaging (MRI) with a human body model are investigated. In particular, the interactions of these fields with an implanted pacemaker are studied. The specific absorption rate (SAR) levels in a heterogeneous body model are evaluated in two different birdcage coils - a resonant and a non-resonant coil - at a magnetic field of 1.5 T. The enhancement of the SAR due to an implanted cardiac pacemaker and the effect of the conductivity of the pacemaker lead on the SAR levels are investigated. The finite difference time domain (FDTD) technique is used to model these interactions. The SAR levels are found to be low in the heart region, and thus the SAR enhancement due to the pacemaker lead is relatively low. Modeling of the pacemaker leads as perfect conductors results in greater SAR enhancements than those produced by actual conductive leads.","abstract_html":"The interactions of the radio frequency (RF) fields in magnetic resonance imaging (MRI) with a human body model are investigated. In particular, the interactions of these fields with an implanted pacemaker are studied. The specific absorption rate (SAR) levels in a heterogeneous body model are evaluated in two different birdcage coils - a resonant and a non-resonant coil - at a magnetic field of 1.5 T. The enhancement of the SAR due to an implanted cardiac pacemaker and the effect of the conductivity of the pacemaker lead on the SAR levels are investigated. The finite difference time domain (FDTD) technique is used to model these interactions. The SAR levels are found to be low in the heart region, and thus the SAR enhancement due to the pacemaker lead is relatively low. Modeling of the pacemaker leads as perfect conductors results in greater SAR enhancements than those produced by actual conductive leads.","abstract_has_math":false,"creators":["Abrishamkar, Houman"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Stuchly, M. A.","Bornemann, J."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-11-13T16:54:10Z","date_published":"2009-11-13T16:54:10Z","updated_at":"2026-11-19T09:38:34Z","subjects":["pacemaker, artificial","magnetic resonance imaging","UVic Subject Index::Sciences and Engineering::Engineering"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1828/1840","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1828/1840","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F1840","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Stuchly, M. A.","Bornemann, J."]},{"key":"dc:creator","label":"Author","values":["Abrishamkar, Houman"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-11-13T16:54:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-11-13T16:54:10Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2005"]},{"key":"dc:date.issued","label":"Date","values":["2009-11-13T16:54:10Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["pacemaker, artificial","magnetic resonance imaging"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["UVic Subject Index::Sciences and Engineering::Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/1840"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The interactions of the radio frequency (RF) fields in magnetic resonance imaging (MRI) with a human body model are investigated. In particular, the interactions of these fields with an implanted pacemaker are studied. The specific absorption rate (SAR) levels in a heterogeneous body model are evaluated in two different birdcage coils - a resonant and a non-resonant coil - at a magnetic field of 1.5 T. The enhancement of the SAR due to an implanted cardiac pacemaker and the effect of the conductivity of the pacemaker lead on the SAR levels are investigated. The finite difference time domain (FDTD) technique is used to model these interactions. The SAR levels are found to be low in the heart region, and thus the SAR enhancement due to the pacemaker lead is relatively low. Modeling of the pacemaker leads as perfect conductors results in greater SAR enhancements than those produced by actual conductive leads."]},{"key":"dc:title","label":"Title","values":["Radio frequency power absorption in a human model with pacemakers in MRI"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Stuchly, M. A.","Bornemann, J."],"dc:creator":["Abrishamkar, Houman"],"dc:date.accessioned":["2009-11-13T16:54:10Z"],"dc:date.available":["2009-11-13T16:54:10Z"],"dc:date.copyright":["2005"],"dc:date.issued":["2009-11-13T16:54:10Z"],"dc:description.abstract":["The interactions of the radio frequency (RF) fields in magnetic resonance imaging (MRI) with a human body model are investigated. In particular, the interactions of these fields with an implanted pacemaker are studied. The specific absorption rate (SAR) levels in a heterogeneous body model are evaluated in two different birdcage coils - a resonant and a non-resonant coil - at a magnetic field of 1.5 T. The enhancement of the SAR due to an implanted cardiac pacemaker and the effect of the conductivity of the pacemaker lead on the SAR levels are investigated. The finite difference time domain (FDTD) technique is used to model these interactions. The SAR levels are found to be low in the heart region, and thus the SAR enhancement due to the pacemaker lead is relatively low. Modeling of the pacemaker leads as perfect conductors results in greater SAR enhancements than those produced by actual conductive leads."],"dc:identifier.uri":["http://hdl.handle.net/1828/1840"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["pacemaker, artificial","magnetic resonance imaging"],"dc:subject.lcsh":["UVic Subject Index::Sciences and Engineering::Engineering"],"dc:title":["Radio frequency power absorption in a human model with pacemakers in MRI"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Electrical and Computer Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:38:34Z"}