{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/18496"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/18496","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"The Development of a cryogenic regenerator test apparatus","abstract":"The Cryofuel Systems Group (CFS) was formed to design a cost effective natural gas refuelling system that delivers liquefied (LNG) and compressed (CNG) natural gas to vehicles. The key component of this refuelling system is the natural gas liquefier. CFS is building an active magnetic regenerative refrigerator (AMRR) for its initial liquefier prototype. This device uses the magnetocaloric effect and a magnetic regenerator to produce refrigeration at LNG temperatures (112 K). The regenerator is a compact heat exchanger that alternately absorbs heat from or releases heat to a fluid during one cycle of operation. The performance of the regenerator is crucial to the overall efficiency of the AMRR. Regenerator performance is usually indicated by its thermal effectiveness, ε, defined as the ratio of the actual heat transfer rate to the maximum possible heat transfer rate. Most regenerator testing methods measure thermal effectiveness by simulating conditions in an actual refrigeration cycle. This thesis describes a simple method of testing regenerators, using an actual regenerative refrigeration cycle based on the Orifice Pulse Tube Refrigerator, to obtain a measure of regenerator effectiveness.","abstract_html":"The Cryofuel Systems Group (CFS) was formed to design a cost effective natural gas refuelling system that delivers liquefied (LNG) and compressed (CNG) natural gas to vehicles. The key component of this refuelling system is the natural gas liquefier. CFS is building an active magnetic regenerative refrigerator (AMRR) for its initial liquefier prototype. This device uses the magnetocaloric effect and a magnetic regenerator to produce refrigeration at LNG temperatures (112 K). The regenerator is a compact heat exchanger that alternately absorbs heat from or releases heat to a fluid during one cycle of operation. The performance of the regenerator is crucial to the overall efficiency of the AMRR. Regenerator performance is usually indicated by its thermal effectiveness, ε, defined as the ratio of the actual heat transfer rate to the maximum possible heat transfer rate. Most regenerator testing methods measure thermal effectiveness by simulating conditions in an actual refrigeration cycle. This thesis describes a simple method of testing regenerators, using an actual regenerative refrigeration cycle based on the Orifice Pulse Tube Refrigerator, to obtain a measure of regenerator effectiveness.","abstract_has_math":false,"creators":["Kratschmar, Kenneth William"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995","date_published":"1995","updated_at":"2026-11-19T09:43:58Z","subjects":[],"languages":[],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1828/18496","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1828/18496","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auvic%3Aoai%3Adspace.library.uvic.ca%3A1828%2F18496","prefix":"oai_dc"},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F18496","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kratschmar, Kenneth William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-14T18:33:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-14T18:33:57Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["1995"]},{"key":"dc:date.issued","label":"Date","values":["1995"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1828/18496"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Cryofuel Systems Group (CFS) was formed to design a cost effective natural gas refuelling system that delivers liquefied (LNG) and compressed (CNG) natural gas to vehicles. The key component of this refuelling system is the natural gas liquefier. CFS is building an active magnetic regenerative refrigerator (AMRR) for its initial liquefier prototype. This device uses the magnetocaloric effect and a magnetic regenerator to produce refrigeration at LNG temperatures (112 K). The regenerator is a compact heat exchanger that alternately absorbs heat from or releases heat to a fluid during one cycle of operation. The performance of the regenerator is crucial to the overall efficiency of the AMRR. Regenerator performance is usually indicated by its thermal effectiveness, ε, defined as the ratio of the actual heat transfer rate to the maximum possible heat transfer rate. Most regenerator testing methods measure thermal effectiveness by simulating conditions in an actual refrigeration cycle. This thesis describes a simple method of testing regenerators, using an actual regenerative refrigeration cycle based on the Orifice Pulse Tube Refrigerator, to obtain a measure of regenerator effectiveness."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["106 pages"]},{"key":"dc:title","label":"Title","values":["The Development of a cryogenic regenerator test apparatus"]}]}],"canonical_facts":{"dc:creator":["Kratschmar, Kenneth William"],"dc:date.accessioned":["2024-08-14T18:33:57Z"],"dc:date.available":["2024-08-14T18:33:57Z"],"dc:date.copyright":["1995"],"dc:date.issued":["1995"],"dc:description.abstract":["The Cryofuel Systems Group (CFS) was formed to design a cost effective natural gas refuelling system that delivers liquefied (LNG) and compressed (CNG) natural gas to vehicles. The key component of this refuelling system is the natural gas liquefier. CFS is building an active magnetic regenerative refrigerator (AMRR) for its initial liquefier prototype. This device uses the magnetocaloric effect and a magnetic regenerator to produce refrigeration at LNG temperatures (112 K). The regenerator is a compact heat exchanger that alternately absorbs heat from or releases heat to a fluid during one cycle of operation. The performance of the regenerator is crucial to the overall efficiency of the AMRR. Regenerator performance is usually indicated by its thermal effectiveness, ε, defined as the ratio of the actual heat transfer rate to the maximum possible heat transfer rate. Most regenerator testing methods measure thermal effectiveness by simulating conditions in an actual refrigeration cycle. This thesis describes a simple method of testing regenerators, using an actual regenerative refrigeration cycle based on the Orifice Pulse Tube Refrigerator, to obtain a measure of regenerator effectiveness."],"dc:format.extent":["106 pages"],"dc:identifier.uri":["https://hdl.handle.net/1828/18496"],"dc:rights":["Available to the World Wide Web"],"dc:title":["The Development of a cryogenic regenerator test apparatus"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Mechanical Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:43:58Z"}