{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/19644"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/19644","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"A Predictive current-mode control technique for constant-frequency PWM DC/DC converters","abstract":"Pulse-width modulated (PWM) de/de converters are widely used in switch-mode power supplies and require appropriate control techniques to meet the demands of fast dynamic response and accurate output voltage regulation. This thesis work investigates a predictive current-mode control (PCC) technique for constant-frequency PWM de/de converters. Using PCC technique, the peak inductor current can be programmed to follow the command current within one switch cycle. The PCC technique has been formulated by applying this current programming requirement into the state-space averaged equations describing the PWM de/de converters. PCC technique, which makes use of feedforward as well as feedback of operating conditions sensed from the power circuit, is an improvement over the conventional cur­rent-mode control (CCC) using hysteresis, because it removes several drawbacks of the latter without sacrificing any of its advantages. For instance, PCC gives rise to an inher­ently stable current loop for the entire range of duty ratio. Therefore, current loop stabili­zation is not needed in PCC, whereas it is necessary in the case of CCC for duty ratios greater than 50%. Also, PCC reduces the error between the command current and the average inductor current. Thus, a lower value for the command current (or threshold) is required to program the same level of the inductor current as in the conventional hyster­etic control scheme. In order to illustrate the operation of the PCC technique, it is implemented for the boost type PWM converter. The PCC current loop characteristics are analyzed in detail and its effects on the overall converter performance are studied. For the purpose of out­put voltage regulation, a feedback network involving a PI-controller and a lead-lag com­pensator is employed and the outer voltage loop is analyzed. Steady state performance and transient performance are evaluated for output impedance and audio susceptibility. All theoretical results are subsequently verified through simulation and experiment.","abstract_html":"Pulse-width modulated (PWM) de/de converters are widely used in switch-mode power supplies and require appropriate control techniques to meet the demands of fast dynamic response and accurate output voltage regulation. This thesis work investigates a predictive current-mode control (PCC) technique for constant-frequency PWM de/de converters. Using PCC technique, the peak inductor current can be programmed to follow the command current within one switch cycle. The PCC technique has been formulated by applying this current programming requirement into the state-space averaged equations describing the PWM de/de converters. PCC technique, which makes use of feedforward as well as feedback of operating conditions sensed from the power circuit, is an improvement over the conventional cur­rent-mode control (CCC) using hysteresis, because it removes several drawbacks of the latter without sacrificing any of its advantages. For instance, PCC gives rise to an inher­ently stable current loop for the entire range of duty ratio. Therefore, current loop stabili­zation is not needed in PCC, whereas it is necessary in the case of CCC for duty ratios greater than 50%. Also, PCC reduces the error between the command current and the average inductor current. Thus, a lower value for the command current (or threshold) is required to program the same level of the inductor current as in the conventional hyster­etic control scheme. In order to illustrate the operation of the PCC technique, it is implemented for the boost type PWM converter. The PCC current loop characteristics are analyzed in detail and its effects on the overall converter performance are studied. For the purpose of out­put voltage regulation, a feedback network involving a PI-controller and a lead-lag com­pensator is employed and the outer voltage loop is analyzed. Steady state performance and transient performance are evaluated for output impedance and audio susceptibility. All theoretical results are subsequently verified through simulation and experiment.","abstract_has_math":false,"creators":["Shanker, Pankaj Mohan"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-11-19T09:44:09Z","subjects":[],"languages":[],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1828/19644","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1828/19644","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F19644","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Shanker, Pankaj Mohan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-15T18:21:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-15T18:21:38Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["1994"]},{"key":"dc:date.issued","label":"Date","values":["1994"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1828/19644"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Pulse-width modulated (PWM) de/de converters are widely used in switch-mode power supplies and require appropriate control techniques to meet the demands of fast dynamic response and accurate output voltage regulation. This thesis work investigates a predictive current-mode control (PCC) technique for constant-frequency PWM de/de converters. Using PCC technique, the peak inductor current can be programmed to follow the command current within one switch cycle. The PCC technique has been formulated by applying this current programming requirement into the state-space averaged equations describing the PWM de/de converters. PCC technique, which makes use of feedforward as well as feedback of operating conditions sensed from the power circuit, is an improvement over the conventional cur­rent-mode control (CCC) using hysteresis, because it removes several drawbacks of the latter without sacrificing any of its advantages. For instance, PCC gives rise to an inher­ently stable current loop for the entire range of duty ratio. Therefore, current loop stabili­zation is not needed in PCC, whereas it is necessary in the case of CCC for duty ratios greater than 50%. Also, PCC reduces the error between the command current and the average inductor current. Thus, a lower value for the command current (or threshold) is required to program the same level of the inductor current as in the conventional hyster­etic control scheme. In order to illustrate the operation of the PCC technique, it is implemented for the boost type PWM converter. The PCC current loop characteristics are analyzed in detail and its effects on the overall converter performance are studied. For the purpose of out­put voltage regulation, a feedback network involving a PI-controller and a lead-lag com­pensator is employed and the outer voltage loop is analyzed. Steady state performance and transient performance are evaluated for output impedance and audio susceptibility. All theoretical results are subsequently verified through simulation and experiment."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["151 pages"]},{"key":"dc:title","label":"Title","values":["A Predictive current-mode control technique for constant-frequency PWM DC/DC converters"]}]}],"canonical_facts":{"dc:creator":["Shanker, Pankaj Mohan"],"dc:date.accessioned":["2024-08-15T18:21:38Z"],"dc:date.available":["2024-08-15T18:21:38Z"],"dc:date.copyright":["1994"],"dc:date.issued":["1994"],"dc:description.abstract":["Pulse-width modulated (PWM) de/de converters are widely used in switch-mode power supplies and require appropriate control techniques to meet the demands of fast dynamic response and accurate output voltage regulation. This thesis work investigates a predictive current-mode control (PCC) technique for constant-frequency PWM de/de converters. Using PCC technique, the peak inductor current can be programmed to follow the command current within one switch cycle. The PCC technique has been formulated by applying this current programming requirement into the state-space averaged equations describing the PWM de/de converters. PCC technique, which makes use of feedforward as well as feedback of operating conditions sensed from the power circuit, is an improvement over the conventional cur­rent-mode control (CCC) using hysteresis, because it removes several drawbacks of the latter without sacrificing any of its advantages. For instance, PCC gives rise to an inher­ently stable current loop for the entire range of duty ratio. Therefore, current loop stabili­zation is not needed in PCC, whereas it is necessary in the case of CCC for duty ratios greater than 50%. Also, PCC reduces the error between the command current and the average inductor current. Thus, a lower value for the command current (or threshold) is required to program the same level of the inductor current as in the conventional hyster­etic control scheme. In order to illustrate the operation of the PCC technique, it is implemented for the boost type PWM converter. The PCC current loop characteristics are analyzed in detail and its effects on the overall converter performance are studied. For the purpose of out­put voltage regulation, a feedback network involving a PI-controller and a lead-lag com­pensator is employed and the outer voltage loop is analyzed. Steady state performance and transient performance are evaluated for output impedance and audio susceptibility. All theoretical results are subsequently verified through simulation and experiment."],"dc:format.extent":["151 pages"],"dc:identifier.uri":["https://hdl.handle.net/1828/19644"],"dc:rights":["Available to the World Wide Web"],"dc:title":["A Predictive current-mode control technique for constant-frequency PWM DC/DC converters"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Electrical and Computer Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:44:09Z"}