{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/23004"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/23004","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Regenerative green hydrogen energy storage modelling for remote northern microgrids","abstract":"Remote Arctic communities in Canada face significant challenges in transitioning from diesel-dependent energy systems to renewable alternatives. While wind, solar, and battery technologies enable successful renewable energy integration, exceeding penetration levels above approximately 60% often requires long-duration energy storage beyond the capabilities of battery technologies. This thesis presents a comprehensive modelling framework for regenerative green hydrogen energy storage within microgrids, addressing critical gaps in energy planning for Arctic communities. This model is then employed to evaluate the potential of green hydrogen energy storage to support Arctic microgrids on the pathway to 100% REP using a community case study based on the Hamlet of Sanirajak, Nunavut. The model demonstrates the feasibility and performance characteristics of hydrogen storage in this Arctic context. Key findings include: (1) significant thermal resilience of the modeled hydrogen system with 40 hours of thermal autonomy, substantial waste heat generation (284,206 kWh annually), and advantages of operation in Arctic climates compared to warm climates; (2) dynamics-based degradation predictions of 3.2% and 1.7% annually for the electrolyzer and fuel cell respectively which are comparable to manufacturer estimates; and (3) water demand of hydrogen storage representing less than 1% of projected 2035 community water consumption. Further, comparative analysis across different modelling timescales indicated that while hourly modelling may miss some of the operational nuances of this storage technology, operational constraints largely compensate for dispatch discrepancies. Case study simulations then evaluated the least-cost designs for REP targets from 50% to 100%, comparing scenarios with and without hydrogen energy storage. The analysis incorporated operational limitations including minimum load ratio, ramping, and compression requirements, as well as a cost sensitivity analysis. Results demonstrate that hydrogen energy storage becomes economically attractive above 65% REP, providing substantial cost savings at high REP by reducing renewable generation over-sizing requirements. However, the model showed that technological limitations such as minimum loading of fuel cells, may limit cost-effective achievement of 100% REP. Beyond economic benefits, this research also identifies practical implementation challenges including harsh environmental conditions, logistical constraints, and local capacity. The model provides community planners and energy operators with novel insights into hydrogen technology performance and operational considerations specific to Arctic microgrid applications. The high level analysis offers contributions to the field by uncovering hydrogen's potential role in Arctic microgrid decarbonization and identifying key technological and practical barriers that must be addressed for successful implementation.","abstract_html":"Remote Arctic communities in Canada face significant challenges in transitioning from diesel-dependent energy systems to renewable alternatives. While wind, solar, and battery technologies enable successful renewable energy integration, exceeding penetration levels above approximately 60% often requires long-duration energy storage beyond the capabilities of battery technologies. This thesis presents a comprehensive modelling framework for regenerative green hydrogen energy storage within microgrids, addressing critical gaps in energy planning for Arctic communities. This model is then employed to evaluate the potential of green hydrogen energy storage to support Arctic microgrids on the pathway to 100% REP using a community case study based on the Hamlet of Sanirajak, Nunavut. The model demonstrates the feasibility and performance characteristics of hydrogen storage in this Arctic context. Key findings include: (1) significant thermal resilience of the modeled hydrogen system with 40 hours of thermal autonomy, substantial waste heat generation (284,206 kWh annually), and advantages of operation in Arctic climates compared to warm climates; (2) dynamics-based degradation predictions of 3.2% and 1.7% annually for the electrolyzer and fuel cell respectively which are comparable to manufacturer estimates; and (3) water demand of hydrogen storage representing less than 1% of projected 2035 community water consumption. Further, comparative analysis across different modelling timescales indicated that while hourly modelling may miss some of the operational nuances of this storage technology, operational constraints largely compensate for dispatch discrepancies. Case study simulations then evaluated the least-cost designs for REP targets from 50% to 100%, comparing scenarios with and without hydrogen energy storage. The analysis incorporated operational limitations including minimum load ratio, ramping, and compression requirements, as well as a cost sensitivity analysis. Results demonstrate that hydrogen energy storage becomes economically attractive above 65% REP, providing substantial cost savings at high REP by reducing renewable generation over-sizing requirements. However, the model showed that technological limitations such as minimum loading of fuel cells, may limit cost-effective achievement of 100% REP. Beyond economic benefits, this research also identifies practical implementation challenges including harsh environmental conditions, logistical constraints, and local capacity. The model provides community planners and energy operators with novel insights into hydrogen technology performance and operational considerations specific to Arctic microgrid applications. The high level analysis offers contributions to the field by uncovering hydrogen&#x27;s potential role in Arctic microgrid decarbonization and identifying key technological and practical barriers that must be addressed for successful implementation.","abstract_has_math":false,"creators":["Janke, Sophie"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science MASc","degree_discipline":null,"degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":["Crawford, Curran"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T09:39:52Z","subjects":["Energy Modelling","Microgrid","Green hydrogen","Energy storage"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["S. Janke, C. Crawford, A. Truelove, M. Lenio, B. Hashemi, Regenerative hydrogen energy storage modelling for northern microgrid energy design, Renewable Energy 256 (2026) 123979. doi:10.1016/j.renene.2025.123979"],"render_values":[{"text":"S. Janke, C. Crawford, A. Truelove, M. Lenio, B. Hashemi, Regenerative hydrogen energy storage modelling for northern microgrid energy design, Renewable Energy 256 (2026) 123979. doi:10.1016/j.renene.2025.123979","href":"https://doi.org/10.1016/j.renene.2025.123979","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1828/23004","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1828/23004","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F23004","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Crawford, Curran"]},{"key":"dc:creator","label":"Author","values":["Janke, Sophie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-12-19T00:37:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-19T00:37:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science MASc"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Energy Modelling","Microgrid","Green hydrogen","Energy storage"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["S. Janke, C. Crawford, A. Truelove, M. Lenio, B. Hashemi, Regenerative hydrogen energy storage modelling for northern microgrid energy design, Renewable Energy 256 (2026) 123979. doi:10.1016/j.renene.2025.123979"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1828/23004"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Remote Arctic communities in Canada face significant challenges in transitioning from diesel-dependent energy systems to renewable alternatives. While wind, solar, and battery technologies enable successful renewable energy integration, exceeding penetration levels above approximately 60% often requires long-duration energy storage beyond the capabilities of battery technologies. This thesis presents a comprehensive modelling framework for regenerative green hydrogen energy storage within microgrids, addressing critical gaps in energy planning for Arctic communities. This model is then employed to evaluate the potential of green hydrogen energy storage to support Arctic microgrids on the pathway to 100% REP using a community case study based on the Hamlet of Sanirajak, Nunavut. The model demonstrates the feasibility and performance characteristics of hydrogen storage in this Arctic context. Key findings include: (1) significant thermal resilience of the modeled hydrogen system with 40 hours of thermal autonomy, substantial waste heat generation (284,206 kWh annually), and advantages of operation in Arctic climates compared to warm climates; (2) dynamics-based degradation predictions of 3.2% and 1.7% annually for the electrolyzer and fuel cell respectively which are comparable to manufacturer estimates; and (3) water demand of hydrogen storage representing less than 1% of projected 2035 community water consumption. Further, comparative analysis across different modelling timescales indicated that while hourly modelling may miss some of the operational nuances of this storage technology, operational constraints largely compensate for dispatch discrepancies. Case study simulations then evaluated the least-cost designs for REP targets from 50% to 100%, comparing scenarios with and without hydrogen energy storage. The analysis incorporated operational limitations including minimum load ratio, ramping, and compression requirements, as well as a cost sensitivity analysis. Results demonstrate that hydrogen energy storage becomes economically attractive above 65% REP, providing substantial cost savings at high REP by reducing renewable generation over-sizing requirements. However, the model showed that technological limitations such as minimum loading of fuel cells, may limit cost-effective achievement of 100% REP. Beyond economic benefits, this research also identifies practical implementation challenges including harsh environmental conditions, logistical constraints, and local capacity. The model provides community planners and energy operators with novel insights into hydrogen technology performance and operational considerations specific to Arctic microgrid applications. The high level analysis offers contributions to the field by uncovering hydrogen's potential role in Arctic microgrid decarbonization and identifying key technological and practical barriers that must be addressed for successful implementation."]},{"key":"dc:description.scholarlevel","label":"Dc Description Scholarlevel","values":["Graduate"]},{"key":"dc:title","label":"Title","values":["Regenerative green hydrogen energy storage modelling for remote northern microgrids"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Crawford, Curran"],"dc:creator":["Janke, Sophie"],"dc:date.accessioned":["2025-12-19T00:37:41Z"],"dc:date.available":["2025-12-19T00:37:41Z"],"dc:date.issued":["2025"],"dc:description.abstract":["Remote Arctic communities in Canada face significant challenges in transitioning from diesel-dependent energy systems to renewable alternatives. While wind, solar, and battery technologies enable successful renewable energy integration, exceeding penetration levels above approximately 60% often requires long-duration energy storage beyond the capabilities of battery technologies. This thesis presents a comprehensive modelling framework for regenerative green hydrogen energy storage within microgrids, addressing critical gaps in energy planning for Arctic communities. This model is then employed to evaluate the potential of green hydrogen energy storage to support Arctic microgrids on the pathway to 100% REP using a community case study based on the Hamlet of Sanirajak, Nunavut. The model demonstrates the feasibility and performance characteristics of hydrogen storage in this Arctic context. Key findings include: (1) significant thermal resilience of the modeled hydrogen system with 40 hours of thermal autonomy, substantial waste heat generation (284,206 kWh annually), and advantages of operation in Arctic climates compared to warm climates; (2) dynamics-based degradation predictions of 3.2% and 1.7% annually for the electrolyzer and fuel cell respectively which are comparable to manufacturer estimates; and (3) water demand of hydrogen storage representing less than 1% of projected 2035 community water consumption. Further, comparative analysis across different modelling timescales indicated that while hourly modelling may miss some of the operational nuances of this storage technology, operational constraints largely compensate for dispatch discrepancies. Case study simulations then evaluated the least-cost designs for REP targets from 50% to 100%, comparing scenarios with and without hydrogen energy storage. The analysis incorporated operational limitations including minimum load ratio, ramping, and compression requirements, as well as a cost sensitivity analysis. Results demonstrate that hydrogen energy storage becomes economically attractive above 65% REP, providing substantial cost savings at high REP by reducing renewable generation over-sizing requirements. However, the model showed that technological limitations such as minimum loading of fuel cells, may limit cost-effective achievement of 100% REP. Beyond economic benefits, this research also identifies practical implementation challenges including harsh environmental conditions, logistical constraints, and local capacity. The model provides community planners and energy operators with novel insights into hydrogen technology performance and operational considerations specific to Arctic microgrid applications. The high level analysis offers contributions to the field by uncovering hydrogen's potential role in Arctic microgrid decarbonization and identifying key technological and practical barriers that must be addressed for successful implementation."],"dc:description.scholarlevel":["Graduate"],"dc:identifier.citation":["S. Janke, C. Crawford, A. Truelove, M. Lenio, B. Hashemi, Regenerative hydrogen energy storage modelling for northern microgrid energy design, Renewable Energy 256 (2026) 123979. doi:10.1016/j.renene.2025.123979"],"dc:identifier.uri":["https://hdl.handle.net/1828/23004"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["Energy Modelling","Microgrid","Green hydrogen","Energy storage"],"dc:title":["Regenerative green hydrogen energy storage modelling for remote northern microgrids"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Mechanical Engineering"],"thesis:degree_level":["Master of Applied Science MASc"]},"updated_at":"2026-11-19T09:39:52Z"}