{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/2960"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/2960","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"A surface roughness parameterization study near two proposed windfarm locations in Southern Ontario","abstract":"This thesis presents a study on the applicability of common roughness parameterization guidelines in determining values of the surface roughness length (z0). These guidelines are often used for vertical extrapolation of wind speeds in the renewable energy industry. The specific goal of this thesis is to determine whether these guidelines (most notably the Davenport roughness classification system) can provide a quality estimate of the roughness length for wind resource assessment purposes. To test this hypothesis, empirical relationships between calculated values of z0 derived from logarithmic profile fitting and those estimated from subjective terrain analyses guidelines are compared at two prospective wind farm locations in Southern Ontario. The results suggest that the use of roughness parameterization guidelines for extrapolating wind speeds can cause serious underestimation of the local wind resources, especially at locations where local topographic challenges exist. Their use in energy assessments should be avoided if possible through on-site measurements of the wind profile.","abstract_html":"This thesis presents a study on the applicability of common roughness parameterization guidelines in determining values of the surface roughness length (z0). These guidelines are often used for vertical extrapolation of wind speeds in the renewable energy industry. The specific goal of this thesis is to determine whether these guidelines (most notably the Davenport roughness classification system) can provide a quality estimate of the roughness length for wind resource assessment purposes. To test this hypothesis, empirical relationships between calculated values of z0 derived from logarithmic profile fitting and those estimated from subjective terrain analyses guidelines are compared at two prospective wind farm locations in Southern Ontario. The results suggest that the use of roughness parameterization guidelines for extrapolating wind speeds can cause serious underestimation of the local wind resources, especially at locations where local topographic challenges exist. Their use in energy assessments should be avoided if possible through on-site measurements of the wind profile.","abstract_has_math":false,"creators":["Laporte, David J."],"institution":null,"degree_name":null,"degree_level":"Master of Science M.Sc.","degree_discipline":null,"degree_department":"Department of Geography","school":null,"contributors":[],"advisors":["Tuller, Stanton E."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-08-24T18:13:57Z","date_published":"2010-08-24T18:13:57Z","updated_at":"2026-11-19T09:47:39Z","subjects":["surface roughness","wind energy","parameterization","UVic Subject Index::Humanities and Social Sciences::Social Sciences::Geography"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1828/2960","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1828/2960","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F2960","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Tuller, Stanton E."]},{"key":"dc:creator","label":"Author","values":["Laporte, David J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-08-24T18:13:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-08-24T18:13:57Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2010"]},{"key":"dc:date.issued","label":"Date","values":["2010-08-24T18:13:57Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Geography"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science M.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["surface roughness","wind energy","parameterization"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["UVic Subject Index::Humanities and Social Sciences::Social Sciences::Geography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/2960"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents a study on the applicability of common roughness parameterization guidelines in determining values of the surface roughness length (z0). These guidelines are often used for vertical extrapolation of wind speeds in the renewable energy industry. The specific goal of this thesis is to determine whether these guidelines (most notably the Davenport roughness classification system) can provide a quality estimate of the roughness length for wind resource assessment purposes. To test this hypothesis, empirical relationships between calculated values of z0 derived from logarithmic profile fitting and those estimated from subjective terrain analyses guidelines are compared at two prospective wind farm locations in Southern Ontario. The results suggest that the use of roughness parameterization guidelines for extrapolating wind speeds can cause serious underestimation of the local wind resources, especially at locations where local topographic challenges exist. Their use in energy assessments should be avoided if possible through on-site measurements of the wind profile."]},{"key":"dc:title","label":"Title","values":["A surface roughness parameterization study near two proposed windfarm locations in Southern Ontario"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Tuller, Stanton E."],"dc:creator":["Laporte, David J."],"dc:date.accessioned":["2010-08-24T18:13:57Z"],"dc:date.available":["2010-08-24T18:13:57Z"],"dc:date.copyright":["2010"],"dc:date.issued":["2010-08-24T18:13:57Z"],"dc:description.abstract":["This thesis presents a study on the applicability of common roughness parameterization guidelines in determining values of the surface roughness length (z0). These guidelines are often used for vertical extrapolation of wind speeds in the renewable energy industry. The specific goal of this thesis is to determine whether these guidelines (most notably the Davenport roughness classification system) can provide a quality estimate of the roughness length for wind resource assessment purposes. To test this hypothesis, empirical relationships between calculated values of z0 derived from logarithmic profile fitting and those estimated from subjective terrain analyses guidelines are compared at two prospective wind farm locations in Southern Ontario. The results suggest that the use of roughness parameterization guidelines for extrapolating wind speeds can cause serious underestimation of the local wind resources, especially at locations where local topographic challenges exist. Their use in energy assessments should be avoided if possible through on-site measurements of the wind profile."],"dc:identifier.uri":["http://hdl.handle.net/1828/2960"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["surface roughness","wind energy","parameterization"],"dc:subject.lcsh":["UVic Subject Index::Humanities and Social Sciences::Social Sciences::Geography"],"dc:title":["A surface roughness parameterization study near two proposed windfarm locations in Southern Ontario"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Geography"],"thesis:degree_level":["Master of Science M.Sc."]},"updated_at":"2026-11-19T09:47:39Z"}