{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/3041"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/3041","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"An evaluation of patient-specific IMRT verification failures","abstract":"At the BC Cancer Agency (BCCA), Vancouver Island Centre (VIC), the clinical verification of Intensity Modulated Radiation Therapy (IMRT) treatment plans involves comparing Portal Image (PI) -based three-dimensionally reconstructed (EPIDose) dose distributions to planned doses calculated using the Pencil Beam Convolution (PBC) algorithm. Discrepancies surpassing established action levels constitute failure. Since 2007, the failure rate of IMRT verification process had been increasing, reaching as high as 18.5% in 2009. A retrospective evaluation of clinical IMRT verification failures was conducted to identify causes and possible resolutions. Thirty clinical verification failures were identified. An equipment malfunction was discovered and subsequently repaired, and several failures were resolved in the process. Statistical uncertainty in measurement outcome was small in comparison to action levels and not considered significant to the production of failures. Still, over 50% of the redelivered plans were shown to consistently fail. A subgroup of consistent verification plans were compared to ion chamber point dose measurements. Relative to ion chamber measurements, EPIDose underestimated the dose while the dose calculation algorithm (PBC, Eclipse version 8.1.18) overestimated the same point dose. Comparisons of individual fields demonstrated that none were identifiably problematic; dose discrepancies were the result of minor but accumulating dose differences. Consistent verification failures were recalculated using two advanced dose calculation engines (the Anisotropic Analytical Algorithm and Monte Carlo). In general, verification metrics improved, and all failures were resolved. Three distinct indices of fluence modulation (or complexity) were shown to correlate with verification metrics. This indicated that deficiencies in both the leaf motion calculator and the PBC (Eclipse version 8.1.18) had likely contributed to the production of failures. In conclusion, clinical verification failures were resolved retrospectively by replacing faulty equipment and using more advanced methods of planned dose calculation, supporting the efficacy and continued use of PI-based three dimensional dose reconstruction for IMRT verification.","abstract_html":"At the BC Cancer Agency (BCCA), Vancouver Island Centre (VIC), the clinical verification of Intensity Modulated Radiation Therapy (IMRT) treatment plans involves comparing Portal Image (PI) -based three-dimensionally reconstructed (EPIDose) dose distributions to planned doses calculated using the Pencil Beam Convolution (PBC) algorithm. Discrepancies surpassing established action levels constitute failure. Since 2007, the failure rate of IMRT verification process had been increasing, reaching as high as 18.5% in 2009. A retrospective evaluation of clinical IMRT verification failures was conducted to identify causes and possible resolutions. Thirty clinical verification failures were identified. An equipment malfunction was discovered and subsequently repaired, and several failures were resolved in the process. Statistical uncertainty in measurement outcome was small in comparison to action levels and not considered significant to the production of failures. Still, over 50% of the redelivered plans were shown to consistently fail. A subgroup of consistent verification plans were compared to ion chamber point dose measurements. Relative to ion chamber measurements, EPIDose underestimated the dose while the dose calculation algorithm (PBC, Eclipse version 8.1.18) overestimated the same point dose. Comparisons of individual fields demonstrated that none were identifiably problematic; dose discrepancies were the result of minor but accumulating dose differences. Consistent verification failures were recalculated using two advanced dose calculation engines (the Anisotropic Analytical Algorithm and Monte Carlo). In general, verification metrics improved, and all failures were resolved. Three distinct indices of fluence modulation (or complexity) were shown to correlate with verification metrics. This indicated that deficiencies in both the leaf motion calculator and the PBC (Eclipse version 8.1.18) had likely contributed to the production of failures. In conclusion, clinical verification failures were resolved retrospectively by replacing faulty equipment and using more advanced methods of planned dose calculation, supporting the efficacy and continued use of PI-based three dimensional dose reconstruction for IMRT verification.","abstract_has_math":false,"creators":["Crawford, Jason"],"institution":null,"degree_name":null,"degree_level":"Master of Science M.Sc.","degree_discipline":null,"degree_department":"Department of Physics and Astronomy","school":null,"contributors":[],"advisors":["Gagne, Isabelle Marie","Jirasek, Andrew"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-09-10T23:59:06Z","date_published":"2010-09-10T23:59:06Z","updated_at":"2026-11-19T09:48:28Z","subjects":["IMRT","EPID","verification","Portal image dose reconstruction","Monte Carlo","Fluence modulation","intensity modulated radiation therapy","ion chamber","UVic Subject Index::Sciences and Engineering::Physics::Radiation","UVic Subject Index::Sciences and Engineering::Physics","UVic Subject Index::Sciences and Engineering::Health Sciences::Oncology"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1828/3041","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1828/3041","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F3041","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Gagne, Isabelle Marie","Jirasek, Andrew"]},{"key":"dc:creator","label":"Author","values":["Crawford, Jason"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-09-10T23:59:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-09-10T23:59:06Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2010"]},{"key":"dc:date.issued","label":"Date","values":["2010-09-10T23:59:06Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Physics and Astronomy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science M.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["IMRT","EPID","verification","Portal image dose reconstruction","Monte Carlo","Fluence modulation","intensity modulated radiation therapy","ion chamber"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["UVic Subject Index::Sciences and Engineering::Physics::Radiation","UVic Subject Index::Sciences and Engineering::Physics","UVic Subject Index::Sciences and Engineering::Health Sciences::Oncology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/3041"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["At the BC Cancer Agency (BCCA), Vancouver Island Centre (VIC), the clinical verification of Intensity Modulated Radiation Therapy (IMRT) treatment plans involves comparing Portal Image (PI) -based three-dimensionally reconstructed (EPIDose) dose distributions to planned doses calculated using the Pencil Beam Convolution (PBC) algorithm. Discrepancies surpassing established action levels constitute failure. Since 2007, the failure rate of IMRT verification process had been increasing, reaching as high as 18.5% in 2009. A retrospective evaluation of clinical IMRT verification failures was conducted to identify causes and possible resolutions. Thirty clinical verification failures were identified. An equipment malfunction was discovered and subsequently repaired, and several failures were resolved in the process. Statistical uncertainty in measurement outcome was small in comparison to action levels and not considered significant to the production of failures. Still, over 50% of the redelivered plans were shown to consistently fail. A subgroup of consistent verification plans were compared to ion chamber point dose measurements. Relative to ion chamber measurements, EPIDose underestimated the dose while the dose calculation algorithm (PBC, Eclipse version 8.1.18) overestimated the same point dose. Comparisons of individual fields demonstrated that none were identifiably problematic; dose discrepancies were the result of minor but accumulating dose differences. Consistent verification failures were recalculated using two advanced dose calculation engines (the Anisotropic Analytical Algorithm and Monte Carlo). In general, verification metrics improved, and all failures were resolved. Three distinct indices of fluence modulation (or complexity) were shown to correlate with verification metrics. This indicated that deficiencies in both the leaf motion calculator and the PBC (Eclipse version 8.1.18) had likely contributed to the production of failures. In conclusion, clinical verification failures were resolved retrospectively by replacing faulty equipment and using more advanced methods of planned dose calculation, supporting the efficacy and continued use of PI-based three dimensional dose reconstruction for IMRT verification."]},{"key":"dc:title","label":"Title","values":["An evaluation of patient-specific IMRT verification failures"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Gagne, Isabelle Marie","Jirasek, Andrew"],"dc:creator":["Crawford, Jason"],"dc:date.accessioned":["2010-09-10T23:59:06Z"],"dc:date.available":["2010-09-10T23:59:06Z"],"dc:date.copyright":["2010"],"dc:date.issued":["2010-09-10T23:59:06Z"],"dc:description.abstract":["At the BC Cancer Agency (BCCA), Vancouver Island Centre (VIC), the clinical verification of Intensity Modulated Radiation Therapy (IMRT) treatment plans involves comparing Portal Image (PI) -based three-dimensionally reconstructed (EPIDose) dose distributions to planned doses calculated using the Pencil Beam Convolution (PBC) algorithm. Discrepancies surpassing established action levels constitute failure. Since 2007, the failure rate of IMRT verification process had been increasing, reaching as high as 18.5% in 2009. A retrospective evaluation of clinical IMRT verification failures was conducted to identify causes and possible resolutions. Thirty clinical verification failures were identified. An equipment malfunction was discovered and subsequently repaired, and several failures were resolved in the process. Statistical uncertainty in measurement outcome was small in comparison to action levels and not considered significant to the production of failures. Still, over 50% of the redelivered plans were shown to consistently fail. A subgroup of consistent verification plans were compared to ion chamber point dose measurements. Relative to ion chamber measurements, EPIDose underestimated the dose while the dose calculation algorithm (PBC, Eclipse version 8.1.18) overestimated the same point dose. Comparisons of individual fields demonstrated that none were identifiably problematic; dose discrepancies were the result of minor but accumulating dose differences. Consistent verification failures were recalculated using two advanced dose calculation engines (the Anisotropic Analytical Algorithm and Monte Carlo). In general, verification metrics improved, and all failures were resolved. Three distinct indices of fluence modulation (or complexity) were shown to correlate with verification metrics. This indicated that deficiencies in both the leaf motion calculator and the PBC (Eclipse version 8.1.18) had likely contributed to the production of failures. In conclusion, clinical verification failures were resolved retrospectively by replacing faulty equipment and using more advanced methods of planned dose calculation, supporting the efficacy and continued use of PI-based three dimensional dose reconstruction for IMRT verification."],"dc:identifier.uri":["http://hdl.handle.net/1828/3041"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["IMRT","EPID","verification","Portal image dose reconstruction","Monte Carlo","Fluence modulation","intensity modulated radiation therapy","ion chamber"],"dc:subject.lcsh":["UVic Subject Index::Sciences and Engineering::Physics::Radiation","UVic Subject Index::Sciences and Engineering::Physics","UVic Subject Index::Sciences and Engineering::Health Sciences::Oncology"],"dc:title":["An evaluation of patient-specific IMRT verification failures"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Physics and Astronomy"],"thesis:degree_level":["Master of Science M.Sc."]},"updated_at":"2026-11-19T09:48:28Z"}