{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/3139"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/3139","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Development of a cell cross flow system","abstract":"Single cell analysis devices have become important tools to obtain unique information on cells to improve current medical techniques, such as tissue engineering, or diagnosis of cancer at an early stage. This thesis documents the development of a \"cell cross flow system\" (CFS), which aims to capture magnetically tagged (MT) cells from a heterogeneous population of cells, and array these cells in pre-determined locations using magnetic force. The CFS integrates a “magnetic single cell micro array” (MSCMA), and a gasket assembly to achieve this. Current single cell technology, relevant fluid and magnetic theory, CFS design process, finite element method (FEM) simulation, and cross flow experiments are detailed in this thesis. The CFS was successful in capturing MT Jurkat cells, and the experimental results were consistent with the FEM simulation analysis. It was found that the CFS was capable of capturing MT Jurkat cells up to a ratio of 1 to 103 (MT to non-magnetically tagged cells) using a cell concentration of 105 cells/mL. Although these results are promising, non-magnetically tagged Jurkat cells were found to adhere to the chip and could not be easily removed. Several recommendations were suggested for future iterations, including changing the gasket assembly design, optimizing the flow rate and cell concentration, and using smaller trap sizes for the MSCMA design.","abstract_html":"Single cell analysis devices have become important tools to obtain unique information on cells to improve current medical techniques, such as tissue engineering, or diagnosis of cancer at an early stage. This thesis documents the development of a &quot;cell cross flow system&quot; (CFS), which aims to capture magnetically tagged (MT) cells from a heterogeneous population of cells, and array these cells in pre-determined locations using magnetic force. The CFS integrates a “magnetic single cell micro array” (MSCMA), and a gasket assembly to achieve this. Current single cell technology, relevant fluid and magnetic theory, CFS design process, finite element method (FEM) simulation, and cross flow experiments are detailed in this thesis. The CFS was successful in capturing MT Jurkat cells, and the experimental results were consistent with the FEM simulation analysis. It was found that the CFS was capable of capturing MT Jurkat cells up to a ratio of 1 to 103 (MT to non-magnetically tagged cells) using a cell concentration of 105 cells/mL. Although these results are promising, non-magnetically tagged Jurkat cells were found to adhere to the chip and could not be easily removed. Several recommendations were suggested for future iterations, including changing the gasket assembly design, optimizing the flow rate and cell concentration, and using smaller trap sizes for the MSCMA design.","abstract_has_math":false,"creators":["Chung, Jessica"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":["Dechev, Nikolai","Park, Edward Jung Wook"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-11-30T00:21:12Z","date_published":"2010-11-30T00:21:12Z","updated_at":"2026-11-19T09:39:36Z","subjects":["Single cell analysis","Cell cross flow","UVic Subject Index::Sciences and Engineering::Engineering::Mechanical engineering"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1828/3139","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1828/3139","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F3139","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Dechev, Nikolai","Park, Edward Jung Wook"]},{"key":"dc:creator","label":"Author","values":["Chung, Jessica"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-11-30T00:21:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-11-30T00:21:12Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2010"]},{"key":"dc:date.issued","label":"Date","values":["2010-11-30T00:21:12Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Single cell analysis","Cell cross flow"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["UVic Subject Index::Sciences and Engineering::Engineering::Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/3139"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Single cell analysis devices have become important tools to obtain unique information on cells to improve current medical techniques, such as tissue engineering, or diagnosis of cancer at an early stage. This thesis documents the development of a \"cell cross flow system\" (CFS), which aims to capture magnetically tagged (MT) cells from a heterogeneous population of cells, and array these cells in pre-determined locations using magnetic force. The CFS integrates a “magnetic single cell micro array” (MSCMA), and a gasket assembly to achieve this. Current single cell technology, relevant fluid and magnetic theory, CFS design process, finite element method (FEM) simulation, and cross flow experiments are detailed in this thesis. The CFS was successful in capturing MT Jurkat cells, and the experimental results were consistent with the FEM simulation analysis. It was found that the CFS was capable of capturing MT Jurkat cells up to a ratio of 1 to 103 (MT to non-magnetically tagged cells) using a cell concentration of 105 cells/mL. Although these results are promising, non-magnetically tagged Jurkat cells were found to adhere to the chip and could not be easily removed. Several recommendations were suggested for future iterations, including changing the gasket assembly design, optimizing the flow rate and cell concentration, and using smaller trap sizes for the MSCMA design."]},{"key":"dc:title","label":"Title","values":["Development of a cell cross flow system"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Dechev, Nikolai","Park, Edward Jung Wook"],"dc:creator":["Chung, Jessica"],"dc:date.accessioned":["2010-11-30T00:21:12Z"],"dc:date.available":["2010-11-30T00:21:12Z"],"dc:date.copyright":["2010"],"dc:date.issued":["2010-11-30T00:21:12Z"],"dc:description.abstract":["Single cell analysis devices have become important tools to obtain unique information on cells to improve current medical techniques, such as tissue engineering, or diagnosis of cancer at an early stage. This thesis documents the development of a \"cell cross flow system\" (CFS), which aims to capture magnetically tagged (MT) cells from a heterogeneous population of cells, and array these cells in pre-determined locations using magnetic force. The CFS integrates a “magnetic single cell micro array” (MSCMA), and a gasket assembly to achieve this. Current single cell technology, relevant fluid and magnetic theory, CFS design process, finite element method (FEM) simulation, and cross flow experiments are detailed in this thesis. The CFS was successful in capturing MT Jurkat cells, and the experimental results were consistent with the FEM simulation analysis. It was found that the CFS was capable of capturing MT Jurkat cells up to a ratio of 1 to 103 (MT to non-magnetically tagged cells) using a cell concentration of 105 cells/mL. Although these results are promising, non-magnetically tagged Jurkat cells were found to adhere to the chip and could not be easily removed. Several recommendations were suggested for future iterations, including changing the gasket assembly design, optimizing the flow rate and cell concentration, and using smaller trap sizes for the MSCMA design."],"dc:identifier.uri":["http://hdl.handle.net/1828/3139"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["Single cell analysis","Cell cross flow"],"dc:subject.lcsh":["UVic Subject Index::Sciences and Engineering::Engineering::Mechanical engineering"],"dc:title":["Development of a cell cross flow system"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Mechanical Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:39:36Z"}