{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/3502"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/3502","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Modelling inductively coupled coils for wireless implantable bio-sensors: a novel approach using the finite element method","abstract":"After nearly a decade of development, human-implantable sensors for detection of muscle activity have recently been demonstrated in the literature. The implantable sensors are powered and communicate wirelessly through the skin using coupled inductor coils. The focus of the present work has been the development of a new approach to modeling the inductively coupled link by using the finite element method (FEM) to simulate a three-dimensional representation of the coils and surrounding magnetic field. The validity of the simulation is tested by comparison to analytically-developed formulas for self-inductance, ac resistance and mutual inductance of the coils. Determination of these parameters is necessary for calculation of the coupling coefficient between the coils, and to fully define the lumped circuit model of the link. This 3D FEM approach is novel and attractive because it is able to encompass physical geometric parameters and material properties that have been traditionally been a challenge to determine. In particular the contribution of a ferrite-core, and the case of non-symmetrical relative coil positioning can be evaluated.","abstract_html":"After nearly a decade of development, human-implantable sensors for detection of muscle activity have recently been demonstrated in the literature. The implantable sensors are powered and communicate wirelessly through the skin using coupled inductor coils. The focus of the present work has been the development of a new approach to modeling the inductively coupled link by using the finite element method (FEM) to simulate a three-dimensional representation of the coils and surrounding magnetic field. The validity of the simulation is tested by comparison to analytically-developed formulas for self-inductance, ac resistance and mutual inductance of the coils. Determination of these parameters is necessary for calculation of the coupling coefficient between the coils, and to fully define the lumped circuit model of the link. This 3D FEM approach is novel and attractive because it is able to encompass physical geometric parameters and material properties that have been traditionally been a challenge to determine. In particular the contribution of a ferrite-core, and the case of non-symmetrical relative coil positioning can be evaluated.","abstract_has_math":false,"creators":["Trezise, Tyler"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":["Dechev, Nikolai"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-08-26","date_published":"2011-08-26","updated_at":"2026-11-19T09:38:29Z","subjects":["FEM","inductive coupling","implantable sensor","comsol","mutual inductance","wireless power","prosthesis control","coupled coils","solenoid inductor","3D coil model","equivalent series resistance","self-inductance","finite element","ferrite"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1828/3502","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1828/3502","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F3502","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Dechev, Nikolai"]},{"key":"dc:creator","label":"Author","values":["Trezise, Tyler"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-08-26T17:35:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-08-26T17:35:31Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2011"]},{"key":"dc:date.issued","label":"Date","values":["2011-08-26"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["FEM","inductive coupling","implantable sensor","comsol","mutual inductance","wireless power","prosthesis control","coupled coils","solenoid inductor","3D coil model","equivalent series resistance","self-inductance","finite element","ferrite"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/3502"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["After nearly a decade of development, human-implantable sensors for detection of muscle activity have recently been demonstrated in the literature. The implantable sensors are powered and communicate wirelessly through the skin using coupled inductor coils. The focus of the present work has been the development of a new approach to modeling the inductively coupled link by using the finite element method (FEM) to simulate a three-dimensional representation of the coils and surrounding magnetic field. The validity of the simulation is tested by comparison to analytically-developed formulas for self-inductance, ac resistance and mutual inductance of the coils. Determination of these parameters is necessary for calculation of the coupling coefficient between the coils, and to fully define the lumped circuit model of the link. This 3D FEM approach is novel and attractive because it is able to encompass physical geometric parameters and material properties that have been traditionally been a challenge to determine. In particular the contribution of a ferrite-core, and the case of non-symmetrical relative coil positioning can be evaluated."]},{"key":"dc:description.scholarlevel","label":"Dc Description Scholarlevel","values":["Graduate"]},{"key":"dc:title","label":"Title","values":["Modelling inductively coupled coils for wireless implantable bio-sensors: a novel approach using the finite element method"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Dechev, Nikolai"],"dc:creator":["Trezise, Tyler"],"dc:date.accessioned":["2011-08-26T17:35:31Z"],"dc:date.available":["2011-08-26T17:35:31Z"],"dc:date.copyright":["2011"],"dc:date.issued":["2011-08-26"],"dc:description.abstract":["After nearly a decade of development, human-implantable sensors for detection of muscle activity have recently been demonstrated in the literature. The implantable sensors are powered and communicate wirelessly through the skin using coupled inductor coils. The focus of the present work has been the development of a new approach to modeling the inductively coupled link by using the finite element method (FEM) to simulate a three-dimensional representation of the coils and surrounding magnetic field. The validity of the simulation is tested by comparison to analytically-developed formulas for self-inductance, ac resistance and mutual inductance of the coils. Determination of these parameters is necessary for calculation of the coupling coefficient between the coils, and to fully define the lumped circuit model of the link. This 3D FEM approach is novel and attractive because it is able to encompass physical geometric parameters and material properties that have been traditionally been a challenge to determine. In particular the contribution of a ferrite-core, and the case of non-symmetrical relative coil positioning can be evaluated."],"dc:description.scholarlevel":["Graduate"],"dc:identifier.uri":["http://hdl.handle.net/1828/3502"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["FEM","inductive coupling","implantable sensor","comsol","mutual inductance","wireless power","prosthesis control","coupled coils","solenoid inductor","3D coil model","equivalent series resistance","self-inductance","finite element","ferrite"],"dc:title":["Modelling inductively coupled coils for wireless implantable bio-sensors: a novel approach using the finite element method"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Mechanical Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:38:29Z"}