{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/4872"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/4872","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"A comparison of oxygen consumption, RPE and lower limb EMG activity in toning versus running shoes on uphill, level and downhill walking","abstract":"OBJECTIVES: Comparing electromyography and physiological measures while walking on various inclines in unstable and stable shoes. METHODS: Eleven healthy females walked on treadmill at +10%, 0% and -10% grade for five minutes each, at self-selected pace, in stable and unstable shoes. The two sessions were done 3weeks apart during which the subjects used unstable shoes for regular activities. Electromyography of lower limb muscles, absolute and relative oxygen consumption, perceived exertion rating and heart rate was calculated. RESULTS: Tibialis anterior activation varied significantly with shoe type, irrespective of grade. Soleus, vastus medialis, and biceps femoris showed activation differences in specific gait phases. There was a main effect for absolute and relative oxygen consumption, RPE and HR only with grade. Shoe type showed no effect. CONCLUSION: Though there is no difference in overall physiological variables, but changes in electromyography in specific phases highlight possible muscle toning benefits of unstable shoes.","abstract_html":"OBJECTIVES: Comparing electromyography and physiological measures while walking on various inclines in unstable and stable shoes. METHODS: Eleven healthy females walked on treadmill at +10%, 0% and -10% grade for five minutes each, at self-selected pace, in stable and unstable shoes. The two sessions were done 3weeks apart during which the subjects used unstable shoes for regular activities. Electromyography of lower limb muscles, absolute and relative oxygen consumption, perceived exertion rating and heart rate was calculated. RESULTS: Tibialis anterior activation varied significantly with shoe type, irrespective of grade. Soleus, vastus medialis, and biceps femoris showed activation differences in specific gait phases. There was a main effect for absolute and relative oxygen consumption, RPE and HR only with grade. Shoe type showed no effect. CONCLUSION: Though there is no difference in overall physiological variables, but changes in electromyography in specific phases highlight possible muscle toning benefits of unstable shoes.","abstract_has_math":false,"creators":["Chatha, Avneet"],"institution":null,"degree_name":null,"degree_level":"Master of Science M.Sc.","degree_discipline":null,"degree_department":"School of Exercise Science, Physical and Health Education","school":null,"contributors":[],"advisors":["Stuart-Hill, Lynneth Ann","Klimstra, Marc D."],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-08-29","date_published":"2013-08-29","updated_at":"2026-11-19T09:38:14Z","subjects":["Unstable shoes","neuromuscular strategy","walking grades","toning","locomotion"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1828/4872","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1828/4872","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F4872","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Stuart-Hill, Lynneth Ann","Klimstra, Marc D."]},{"key":"dc:creator","label":"Author","values":["Chatha, Avneet"]},{"key":"person:email","label":"Person Email","values":["avneetchatha@gmail.com"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-29T23:16:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-08-29T23:16:51Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2013"]},{"key":"dc:date.issued","label":"Date","values":["2013-08-29"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Exercise Science, Physical and Health Education"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science M.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Unstable shoes","neuromuscular strategy","walking grades","toning","locomotion"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["0350","0354","0382"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/4872"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["OBJECTIVES: Comparing electromyography and physiological measures while walking on various inclines in unstable and stable shoes. METHODS: Eleven healthy females walked on treadmill at +10%, 0% and -10% grade for five minutes each, at self-selected pace, in stable and unstable shoes. The two sessions were done 3weeks apart during which the subjects used unstable shoes for regular activities. Electromyography of lower limb muscles, absolute and relative oxygen consumption, perceived exertion rating and heart rate was calculated. RESULTS: Tibialis anterior activation varied significantly with shoe type, irrespective of grade. Soleus, vastus medialis, and biceps femoris showed activation differences in specific gait phases. There was a main effect for absolute and relative oxygen consumption, RPE and HR only with grade. Shoe type showed no effect. CONCLUSION: Though there is no difference in overall physiological variables, but changes in electromyography in specific phases highlight possible muscle toning benefits of unstable shoes."]},{"key":"dc:description.scholarlevel","label":"Dc Description Scholarlevel","values":["Graduate"]},{"key":"dc:title","label":"Title","values":["A comparison of oxygen consumption, RPE and lower limb EMG activity in toning versus running shoes on uphill, level and downhill walking"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Stuart-Hill, Lynneth Ann","Klimstra, Marc D."],"dc:creator":["Chatha, Avneet"],"dc:date.accessioned":["2013-08-29T23:16:51Z"],"dc:date.available":["2013-08-29T23:16:51Z"],"dc:date.copyright":["2013"],"dc:date.issued":["2013-08-29"],"dc:description.abstract":["OBJECTIVES: Comparing electromyography and physiological measures while walking on various inclines in unstable and stable shoes. METHODS: Eleven healthy females walked on treadmill at +10%, 0% and -10% grade for five minutes each, at self-selected pace, in stable and unstable shoes. The two sessions were done 3weeks apart during which the subjects used unstable shoes for regular activities. Electromyography of lower limb muscles, absolute and relative oxygen consumption, perceived exertion rating and heart rate was calculated. RESULTS: Tibialis anterior activation varied significantly with shoe type, irrespective of grade. Soleus, vastus medialis, and biceps femoris showed activation differences in specific gait phases. There was a main effect for absolute and relative oxygen consumption, RPE and HR only with grade. Shoe type showed no effect. CONCLUSION: Though there is no difference in overall physiological variables, but changes in electromyography in specific phases highlight possible muscle toning benefits of unstable shoes."],"dc:description.scholarlevel":["Graduate"],"dc:identifier.uri":["http://hdl.handle.net/1828/4872"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["Unstable shoes","neuromuscular strategy","walking grades","toning","locomotion"],"dc:subject.proquest":["0350","0354","0382"],"dc:title":["A comparison of oxygen consumption, RPE and lower limb EMG activity in toning versus running shoes on uphill, level and downhill walking"],"dc:type":["Thesis"],"person:email":["avneetchatha@gmail.com"],"thesis:degree_department":["School of Exercise Science, Physical and Health Education"],"thesis:degree_level":["Master of Science M.Sc."]},"updated_at":"2026-11-19T09:38:14Z"}