{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/6108"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/6108","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Investigation of calculated adiabatic temperature change of MnFeP1-xAsx alloys","abstract":"Magnetic refrigeration is an alternative cooling technology to vapour compression. Due to the large operating space of magnetic refrigeration devices, modelling is critical to predict results, optimize device parameters and regenerator design, and understand the physics of the system. Modeling requires accurate material data including specific heat, magnetization and adiabatic temperature change, . For a reversible material can be attained directly from measurement or indirectly through calculation from specific heat and magnetization data. Data sets of nine MnFeP1-xAsx alloys are used to compare calculated against measured . MnFeP1-xAsx is a promising first order material because of a tunable transition temperature, low material cost and large magnetocaloric properties. Because MnFeP1-xAsx alloys exhibit thermal hysteresis there are four possible calculation protocols for adiabatic temperature change; , , and . deviates the most from measured data and therefore it is assumed that this case is not representative of the material behavior. Results show and align with measured data as well as . The three protocols that align best with measured data have two consistent errors including a colder peak and a larger . With more data sets and analysis a preferred calculation protocol may be found.","abstract_html":"Magnetic refrigeration is an alternative cooling technology to vapour compression. Due to the large operating space of magnetic refrigeration devices, modelling is critical to predict results, optimize device parameters and regenerator design, and understand the physics of the system. Modeling requires accurate material data including specific heat, magnetization and adiabatic temperature change, . For a reversible material can be attained directly from measurement or indirectly through calculation from specific heat and magnetization data. Data sets of nine MnFeP1-xAsx alloys are used to compare calculated against measured . MnFeP1-xAsx is a promising first order material because of a tunable transition temperature, low material cost and large magnetocaloric properties. Because MnFeP1-xAsx alloys exhibit thermal hysteresis there are four possible calculation protocols for adiabatic temperature change; , , and . deviates the most from measured data and therefore it is assumed that this case is not representative of the material behavior. Results show and align with measured data as well as . The three protocols that align best with measured data have two consistent errors including a colder peak and a larger . With more data sets and analysis a preferred calculation protocol may be found.","abstract_has_math":false,"creators":["Campbell, David Oliver"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":["Rowe, Andrew Michael"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-04-30","date_published":"2015-04-30","updated_at":"2026-11-19T09:44:14Z","subjects":["magnetic refrigeration","MnFePAs","refrigeration","hysteresis","adiabatic temperature change","Institute for Integrated Energy Systems (IESVic)"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":["http://creativecommons.org/publicdomain/zero/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1828/6108","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1828/6108","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auvic%3Aoai%3Adspace.library.uvic.ca%3A1828%2F6108","prefix":"oai_dc"},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F6108","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Rowe, Andrew Michael"]},{"key":"dc:creator","label":"Author","values":["Campbell, David Oliver"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-04-30T22:58:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-04-30T22:58:23Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015"]},{"key":"dc:date.issued","label":"Date","values":["2015-04-30"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["magnetic refrigeration","MnFePAs","refrigeration","hysteresis","adiabatic temperature change","Institute for Integrated Energy Systems (IESVic)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/publicdomain/zero/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/6108"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Magnetic refrigeration is an alternative cooling technology to vapour compression. Due to the large operating space of magnetic refrigeration devices, modelling is critical to predict results, optimize device parameters and regenerator design, and understand the physics of the system. Modeling requires accurate material data including specific heat, magnetization and adiabatic temperature change, . For a reversible material can be attained directly from measurement or indirectly through calculation from specific heat and magnetization data. Data sets of nine MnFeP1-xAsx alloys are used to compare calculated against measured . MnFeP1-xAsx is a promising first order material because of a tunable transition temperature, low material cost and large magnetocaloric properties. Because MnFeP1-xAsx alloys exhibit thermal hysteresis there are four possible calculation protocols for adiabatic temperature change; , , and . deviates the most from measured data and therefore it is assumed that this case is not representative of the material behavior. Results show and align with measured data as well as . The three protocols that align best with measured data have two consistent errors including a colder peak and a larger . With more data sets and analysis a preferred calculation protocol may be found."]},{"key":"dc:description.scholarlevel","label":"Dc Description Scholarlevel","values":["Graduate"]},{"key":"dc:title","label":"Title","values":["Investigation of calculated adiabatic temperature change of MnFeP1-xAsx alloys"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Rowe, Andrew Michael"],"dc:creator":["Campbell, David Oliver"],"dc:date.accessioned":["2015-04-30T22:58:23Z"],"dc:date.available":["2015-04-30T22:58:23Z"],"dc:date.copyright":["2015"],"dc:date.issued":["2015-04-30"],"dc:description.abstract":["Magnetic refrigeration is an alternative cooling technology to vapour compression. Due to the large operating space of magnetic refrigeration devices, modelling is critical to predict results, optimize device parameters and regenerator design, and understand the physics of the system. Modeling requires accurate material data including specific heat, magnetization and adiabatic temperature change, . For a reversible material can be attained directly from measurement or indirectly through calculation from specific heat and magnetization data. Data sets of nine MnFeP1-xAsx alloys are used to compare calculated against measured . MnFeP1-xAsx is a promising first order material because of a tunable transition temperature, low material cost and large magnetocaloric properties. Because MnFeP1-xAsx alloys exhibit thermal hysteresis there are four possible calculation protocols for adiabatic temperature change; , , and . deviates the most from measured data and therefore it is assumed that this case is not representative of the material behavior. Results show and align with measured data as well as . The three protocols that align best with measured data have two consistent errors including a colder peak and a larger . With more data sets and analysis a preferred calculation protocol may be found."],"dc:description.scholarlevel":["Graduate"],"dc:identifier.uri":["http://hdl.handle.net/1828/6108"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:rights.uri":["http://creativecommons.org/publicdomain/zero/1.0/"],"dc:subject":["magnetic refrigeration","MnFePAs","refrigeration","hysteresis","adiabatic temperature change","Institute for Integrated Energy Systems (IESVic)"],"dc:title":["Investigation of calculated adiabatic temperature change of MnFeP1-xAsx alloys"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Mechanical Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:44:14Z"}