{"id":{"repo_id":"uvic","oai_identifier":"oai:dspace.library.uvic.ca:1828/6701"},"canonical_url":"https://search.ndltd.org/etd/uvic/oai:dspace.library.uvic.ca:1828/6701","repository":{"repo_id":"uvic","name":"University of Victoria (Canada)","base_url":"https://dspace.library.uvic.ca/server/oai/request"},"display":{"title":"Dead Volume Effects in Passive Regeneration: Experimental and Numerical Characterization","abstract":"The regenerator is the key component in magnetic cycles for refrigeration and heat pumping. It works as temporal thermal energy storage and separates two thermal reservoirs. Regenerators are typically made up of porous structures which may create complex flow pathways for the heat transfer fluid through the regenerator. The periodically reversing flow allows the thermal energy exchange with the packing material in the regenerators. The performance of such thermal devices depends greatly on the geometry of the porous structure, material properties as well as operating conditions. This thesis is a study about the thermo-hydraulic properties of passive regenerators under oscillating flow conditions. The first part of the thesis presents a passive regenerator testing apparatus used to measure temperature distribution and pressure drop for various types of regenerators. Three kinds of loose spheres packed regenerator beds are characterized, and the regenerator effectiveness is evaluated. In the second part of the thesis, a numerical model is developed for the predictions of pressure drop and temperature field, and the theoretical findings are applied to experimentally obtained data to interpret regenerator performance. The dead volume is investigated quantitatively and considered to affect the regenerator performance adversely.","abstract_html":"The regenerator is the key component in magnetic cycles for refrigeration and heat pumping. It works as temporal thermal energy storage and separates two thermal reservoirs. Regenerators are typically made up of porous structures which may create complex flow pathways for the heat transfer fluid through the regenerator. The periodically reversing flow allows the thermal energy exchange with the packing material in the regenerators. The performance of such thermal devices depends greatly on the geometry of the porous structure, material properties as well as operating conditions. This thesis is a study about the thermo-hydraulic properties of passive regenerators under oscillating flow conditions. The first part of the thesis presents a passive regenerator testing apparatus used to measure temperature distribution and pressure drop for various types of regenerators. Three kinds of loose spheres packed regenerator beds are characterized, and the regenerator effectiveness is evaluated. In the second part of the thesis, a numerical model is developed for the predictions of pressure drop and temperature field, and the theoretical findings are applied to experimentally obtained data to interpret regenerator performance. The dead volume is investigated quantitatively and considered to affect the regenerator performance adversely.","abstract_has_math":false,"creators":["Liu, Yifeng"],"institution":null,"degree_name":null,"degree_level":"Master of Applied Science M.A.Sc.","degree_discipline":null,"degree_department":"Department of Mechanical Engineering","school":null,"contributors":[],"advisors":["Rowe, Andrew Michael"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-17","date_published":"2015-09-17","updated_at":"2026-11-19T09:42:37Z","subjects":["dead volume","effectiveness","regenerator","simulation","Institute for Integrated Energy Systems (IESVic)"],"languages":["en","English"],"rights":["Available to the World Wide Web"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["P. Trevizoli, Y. Liu, A. Tura, A. Rowe, and J. Barbosa, “Experimental assessment of the thermal–hydraulic performance of packed-sphere oscillating-flow regenerators using water,” Exp. Therm. Fluid Sci., vol. 57, pp. 324–334, Sep. 2014."],"render_values":[{"text":"P. Trevizoli, Y. Liu, A. Tura, A. Rowe, and J. Barbosa, “Experimental assessment of the thermal–hydraulic performance of packed-sphere oscillating-flow regenerators using water,” Exp. Therm. Fluid Sci., vol. 57, pp. 324–334, Sep. 2014.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1828/6701","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1828/6701","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dspace.library.uvic.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.library.uvic.ca%3A1828%2F6701","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Rowe, Andrew Michael"]},{"key":"dc:creator","label":"Author","values":["Liu, Yifeng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-17T20:18:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-17T20:18:43Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015"]},{"key":"dc:date.issued","label":"Date","values":["2015-09-17"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science M.A.Sc."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dead volume","effectiveness","regenerator","simulation","Institute for Integrated Energy Systems (IESVic)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Available to the World Wide Web"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["P. Trevizoli, Y. Liu, A. Tura, A. Rowe, and J. Barbosa, “Experimental assessment of the thermal–hydraulic performance of packed-sphere oscillating-flow regenerators using water,” Exp. Therm. Fluid Sci., vol. 57, pp. 324–334, Sep. 2014."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1828/6701"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The regenerator is the key component in magnetic cycles for refrigeration and heat pumping. It works as temporal thermal energy storage and separates two thermal reservoirs. Regenerators are typically made up of porous structures which may create complex flow pathways for the heat transfer fluid through the regenerator. The periodically reversing flow allows the thermal energy exchange with the packing material in the regenerators. The performance of such thermal devices depends greatly on the geometry of the porous structure, material properties as well as operating conditions. This thesis is a study about the thermo-hydraulic properties of passive regenerators under oscillating flow conditions. The first part of the thesis presents a passive regenerator testing apparatus used to measure temperature distribution and pressure drop for various types of regenerators. Three kinds of loose spheres packed regenerator beds are characterized, and the regenerator effectiveness is evaluated. In the second part of the thesis, a numerical model is developed for the predictions of pressure drop and temperature field, and the theoretical findings are applied to experimentally obtained data to interpret regenerator performance. The dead volume is investigated quantitatively and considered to affect the regenerator performance adversely."]},{"key":"dc:description.scholarlevel","label":"Dc Description Scholarlevel","values":["Graduate"]},{"key":"dc:title","label":"Title","values":["Dead Volume Effects in Passive Regeneration: Experimental and Numerical Characterization"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Rowe, Andrew Michael"],"dc:creator":["Liu, Yifeng"],"dc:date.accessioned":["2015-09-17T20:18:43Z"],"dc:date.available":["2015-09-17T20:18:43Z"],"dc:date.copyright":["2015"],"dc:date.issued":["2015-09-17"],"dc:description.abstract":["The regenerator is the key component in magnetic cycles for refrigeration and heat pumping. It works as temporal thermal energy storage and separates two thermal reservoirs. Regenerators are typically made up of porous structures which may create complex flow pathways for the heat transfer fluid through the regenerator. The periodically reversing flow allows the thermal energy exchange with the packing material in the regenerators. The performance of such thermal devices depends greatly on the geometry of the porous structure, material properties as well as operating conditions. This thesis is a study about the thermo-hydraulic properties of passive regenerators under oscillating flow conditions. The first part of the thesis presents a passive regenerator testing apparatus used to measure temperature distribution and pressure drop for various types of regenerators. Three kinds of loose spheres packed regenerator beds are characterized, and the regenerator effectiveness is evaluated. In the second part of the thesis, a numerical model is developed for the predictions of pressure drop and temperature field, and the theoretical findings are applied to experimentally obtained data to interpret regenerator performance. The dead volume is investigated quantitatively and considered to affect the regenerator performance adversely."],"dc:description.scholarlevel":["Graduate"],"dc:identifier.citation":["P. Trevizoli, Y. Liu, A. Tura, A. Rowe, and J. Barbosa, “Experimental assessment of the thermal–hydraulic performance of packed-sphere oscillating-flow regenerators using water,” Exp. Therm. Fluid Sci., vol. 57, pp. 324–334, Sep. 2014."],"dc:identifier.uri":["http://hdl.handle.net/1828/6701"],"dc:language":["English"],"dc:language.iso":["en"],"dc:rights":["Available to the World Wide Web"],"dc:subject":["dead volume","effectiveness","regenerator","simulation","Institute for Integrated Energy Systems (IESVic)"],"dc:title":["Dead Volume Effects in Passive Regeneration: Experimental and Numerical Characterization"],"dc:type":["Thesis"],"thesis:degree_department":["Department of Mechanical Engineering"],"thesis:degree_level":["Master of Applied Science M.A.Sc."]},"updated_at":"2026-11-19T09:42:37Z"}