{"id":{"repo_id":"uwo","oai_identifier":"oai:uwo.scholaris.ca:20.500.14721/39655"},"canonical_url":"https://search.ndltd.org/etd/uwo/oai:uwo.scholaris.ca:20.500.14721/39655","repository":{"repo_id":"uwo","name":"Western University","base_url":"https://uwo.scholaris.ca/server/oai/request"},"display":{"title":"NeuroNeck: Reliability and Multidimensional Assessment of NeuroNeck: Reliability and Multidimensional Assessment of Cervical Function Using Immersive Technologies Cervical Function Using Immersive Technologies","abstract":"Neck pain is among the most prevalent musculoskeletal conditions worldwide and a leading contributor to disability and reduced quality of life. Accurate and reliable assessment of cervical function is therefore essential for clinical diagnosis, rehabilitation planning, and longitudinal monitoring. However, conventional assessments primarily rely on manual range of-motion (ROM) measurements and qualitative observation, providing limited insight into the dynamic and functional characteristics of cervical movement. Traditional ROM-based evaluations capture static endpoints of motion but do not quantify key performance dimensions such as movement speed, visuomotor responsiveness, spatial accuracy, and proprioceptive control. Furthermore, these assessments are susceptible to variability arising from examiner dependent procedures and participant-related factors, limiting their sensitivity to detect meaningful changes over time. This thesis investigates the reliability and measurement consistency of motion-derived cervical metrics obtained through immersive, task-based assessment. To support this, NeuroNeck was developed as an immersive assessment system implemented across augmented reality (AR) and virtual reality (VR) conditions within the broader mixed-reality continuum to capture multidimensional cervical kinematics during structured tasks targeting mobility, visuomotor response, continuous sensorimotor control, and proprioceptive accuracy. A controlled experimental study was conducted to evaluate test–retest reliability and agreement of these metrics across repeated sessions and immersive modalities (augmented reality and virtual reality). Reliability was quantified using intraclass correlation coefficients and measurement error indices to determine the stability of each outcome. The findings provide evidence on the measurement properties of immersive cervical metrics and identify which dimensions demonstrate sufficient consistency for longitudinal assessment. This work contributes toward more objective, multidimensional approaches for cervical evaluation beyond traditional ROM-based methods.","abstract_html":"Neck pain is among the most prevalent musculoskeletal conditions worldwide and a leading contributor to disability and reduced quality of life. Accurate and reliable assessment of cervical function is therefore essential for clinical diagnosis, rehabilitation planning, and longitudinal monitoring. However, conventional assessments primarily rely on manual range of-motion (ROM) measurements and qualitative observation, providing limited insight into the dynamic and functional characteristics of cervical movement. Traditional ROM-based evaluations capture static endpoints of motion but do not quantify key performance dimensions such as movement speed, visuomotor responsiveness, spatial accuracy, and proprioceptive control. Furthermore, these assessments are susceptible to variability arising from examiner dependent procedures and participant-related factors, limiting their sensitivity to detect meaningful changes over time. This thesis investigates the reliability and measurement consistency of motion-derived cervical metrics obtained through immersive, task-based assessment. To support this, NeuroNeck was developed as an immersive assessment system implemented across augmented reality (AR) and virtual reality (VR) conditions within the broader mixed-reality continuum to capture multidimensional cervical kinematics during structured tasks targeting mobility, visuomotor response, continuous sensorimotor control, and proprioceptive accuracy. A controlled experimental study was conducted to evaluate test–retest reliability and agreement of these metrics across repeated sessions and immersive modalities (augmented reality and virtual reality). Reliability was quantified using intraclass correlation coefficients and measurement error indices to determine the stability of each outcome. The findings provide evidence on the measurement properties of immersive cervical metrics and identify which dimensions demonstrate sufficient consistency for longitudinal assessment. This work contributes toward more objective, multidimensional approaches for cervical evaluation beyond traditional ROM-based methods.","abstract_has_math":false,"creators":["Naeem, Abdul Wahab"],"institution":"The University of Western Ontario","degree_name":"M Sc","degree_level":null,"degree_discipline":"Computer Science","degree_department":null,"school":null,"contributors":[],"advisors":["Rehman, Umair"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-04-21","date_published":"2026-04-21","updated_at":"2026-11-26T14:05:27Z","subjects":["rehabilitation","augmented reality","virtual reality","neckpain","consistency","metrics","immersive methods"],"languages":["en"],"rights":["Abdul Wahab Naeem, 2026","Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14721/39655","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14721/39655","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auwo%3Aoai%3Auwo.scholaris.ca%3A20.500.14721%2F39655","prefix":"oai_dc"},"source_record":{"url":"https://uwo.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Auwo.scholaris.ca%3A20.500.14721%2F39655","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rehman, Umair"]},{"key":"dc:creator","label":"Author","values":["Naeem, Abdul Wahab"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-05-12T18:50:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-04-21"]},{"key":"dc:publisher","label":"Institution","values":["The University of Western Ontario"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computer Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M Sc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The University of Western Ontario"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["rehabilitation","augmented reality","virtual reality","neckpain","consistency","metrics","immersive methods"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Abdul Wahab Naeem, 2026","Attribution-NonCommercial-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14721/39655"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Neck pain is among the most prevalent musculoskeletal conditions worldwide and a leading contributor to disability and reduced quality of life. Accurate and reliable assessment of cervical function is therefore essential for clinical diagnosis, rehabilitation planning, and longitudinal monitoring. However, conventional assessments primarily rely on manual range of-motion (ROM) measurements and qualitative observation, providing limited insight into the dynamic and functional characteristics of cervical movement. Traditional ROM-based evaluations capture static endpoints of motion but do not quantify key performance dimensions such as movement speed, visuomotor responsiveness, spatial accuracy, and proprioceptive control. Furthermore, these assessments are susceptible to variability arising from examiner dependent procedures and participant-related factors, limiting their sensitivity to detect meaningful changes over time. This thesis investigates the reliability and measurement consistency of motion-derived cervical metrics obtained through immersive, task-based assessment. To support this, NeuroNeck was developed as an immersive assessment system implemented across augmented reality (AR) and virtual reality (VR) conditions within the broader mixed-reality continuum to capture multidimensional cervical kinematics during structured tasks targeting mobility, visuomotor response, continuous sensorimotor control, and proprioceptive accuracy. A controlled experimental study was conducted to evaluate test–retest reliability and agreement of these metrics across repeated sessions and immersive modalities (augmented reality and virtual reality). Reliability was quantified using intraclass correlation coefficients and measurement error indices to determine the stability of each outcome. The findings provide evidence on the measurement properties of immersive cervical metrics and identify which dimensions demonstrate sufficient consistency for longitudinal assessment. This work contributes toward more objective, multidimensional approaches for cervical evaluation beyond traditional ROM-based methods."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Neck pain is a very common condition that can affect daily activities, comfort, and overall quality of life. In clinical practice, neck function is usually assessed by measuring how far a person can move their head in different directions. While this provides useful information about mobility, it does not capture how well the movement is performed. Important aspects such as how quickly a person reacts, how accurately they control movement, and how precisely they can reposition their head are often not measured. This thesis explores whether immersive technologies, such as virtual reality (VR) and augmented reality (AR), can provide a more complete and objective way to assess neck function. A game-based system called NeuroNeck was developed to measure multiple aspects of cervical performance, including movement range, reaction time, precision, and proprioceptive accuracy, during interactive tasks. The main goal of this research is not to treat neck pain, but to determine whether these motion-based measurements are reliable and consistent over repeated testing sessions and across different immersive environments. Establishing reliability is essential before such systems can be used confidently in clinical or research settings. The findings of this work help identify which measurements are stable and meaningful, and which may be more variable. Overall, this research contributes toward developing more objective, engaging, and functionally informative methods for assessing neck movement beyond traditional approaches."]},{"key":"dc:title","label":"Title","values":["NeuroNeck: Reliability and Multidimensional Assessment of NeuroNeck: Reliability and Multidimensional Assessment of Cervical Function Using Immersive Technologies Cervical Function Using Immersive Technologies"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rehman, Umair"],"dc:creator":["Naeem, Abdul Wahab"],"dc:date.accessioned":["2026-05-12T18:50:36Z"],"dc:date.issued":["2026-04-21"],"dc:description.abstract":["Neck pain is among the most prevalent musculoskeletal conditions worldwide and a leading contributor to disability and reduced quality of life. Accurate and reliable assessment of cervical function is therefore essential for clinical diagnosis, rehabilitation planning, and longitudinal monitoring. However, conventional assessments primarily rely on manual range of-motion (ROM) measurements and qualitative observation, providing limited insight into the dynamic and functional characteristics of cervical movement. Traditional ROM-based evaluations capture static endpoints of motion but do not quantify key performance dimensions such as movement speed, visuomotor responsiveness, spatial accuracy, and proprioceptive control. Furthermore, these assessments are susceptible to variability arising from examiner dependent procedures and participant-related factors, limiting their sensitivity to detect meaningful changes over time. This thesis investigates the reliability and measurement consistency of motion-derived cervical metrics obtained through immersive, task-based assessment. To support this, NeuroNeck was developed as an immersive assessment system implemented across augmented reality (AR) and virtual reality (VR) conditions within the broader mixed-reality continuum to capture multidimensional cervical kinematics during structured tasks targeting mobility, visuomotor response, continuous sensorimotor control, and proprioceptive accuracy. A controlled experimental study was conducted to evaluate test–retest reliability and agreement of these metrics across repeated sessions and immersive modalities (augmented reality and virtual reality). Reliability was quantified using intraclass correlation coefficients and measurement error indices to determine the stability of each outcome. The findings provide evidence on the measurement properties of immersive cervical metrics and identify which dimensions demonstrate sufficient consistency for longitudinal assessment. This work contributes toward more objective, multidimensional approaches for cervical evaluation beyond traditional ROM-based methods."],"dc:description.abstractgeneral":["Neck pain is a very common condition that can affect daily activities, comfort, and overall quality of life. In clinical practice, neck function is usually assessed by measuring how far a person can move their head in different directions. While this provides useful information about mobility, it does not capture how well the movement is performed. Important aspects such as how quickly a person reacts, how accurately they control movement, and how precisely they can reposition their head are often not measured. This thesis explores whether immersive technologies, such as virtual reality (VR) and augmented reality (AR), can provide a more complete and objective way to assess neck function. A game-based system called NeuroNeck was developed to measure multiple aspects of cervical performance, including movement range, reaction time, precision, and proprioceptive accuracy, during interactive tasks. The main goal of this research is not to treat neck pain, but to determine whether these motion-based measurements are reliable and consistent over repeated testing sessions and across different immersive environments. Establishing reliability is essential before such systems can be used confidently in clinical or research settings. The findings of this work help identify which measurements are stable and meaningful, and which may be more variable. Overall, this research contributes toward developing more objective, engaging, and functionally informative methods for assessing neck movement beyond traditional approaches."],"dc:identifier.uri":["https://hdl.handle.net/20.500.14721/39655"],"dc:language.iso":["en"],"dc:publisher":["The University of Western Ontario"],"dc:rights":["Abdul Wahab Naeem, 2026","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["rehabilitation","augmented reality","virtual reality","neckpain","consistency","metrics","immersive methods"],"dc:title":["NeuroNeck: Reliability and Multidimensional Assessment of NeuroNeck: Reliability and Multidimensional Assessment of Cervical Function Using Immersive Technologies Cervical Function Using Immersive Technologies"],"dc:type":["thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Computer Science"],"thesis:degree_name":["M Sc"],"thesis:institution_name":["The University of Western Ontario"]},"updated_at":"2026-11-26T14:05:27Z"}