{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-2923"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-2923","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"THE USE OF A TRI-AXIAL ACCELEROMETER TO MEASURE CHANGES IN LOWER EXTREMITY FATIGUE DURING FUNCTIONAL ACTIVITY","abstract":"In 2004, the National Collegiate Athletic Association reported ankle sprain as the most frequent injury in soccer, basketball, and volleyball players. Further research found an increased likelihood with fatigue. Measuring fatigue during functional activities has been a longstanding problem. In this study, changes in ankle biomechanics were measured using a tri-axial accelerometer embedded in the shoe as subjects (n=12) performed a fatiguing activity. Data were collected from the accelerometer and from established devices that are considered the industry gold standard. Several kinetic and kinematic accelerometer derived variables were highly correlated with these standards (r2>0.90) and were associated with changes in fatigue. The tri-axial accelerometer in this configuration may be suitable for monitoring fatigue during the performance of functional activities.","abstract_html":"In 2004, the National Collegiate Athletic Association reported ankle sprain as the most frequent injury in soccer, basketball, and volleyball players. Further research found an increased likelihood with fatigue. Measuring fatigue during functional activities has been a longstanding problem. In this study, changes in ankle biomechanics were measured using a tri-axial accelerometer embedded in the shoe as subjects (n=12) performed a fatiguing activity. Data were collected from the accelerometer and from established devices that are considered the industry gold standard. Several kinetic and kinematic accelerometer derived variables were highly correlated with these standards (r2&gt;0.90) and were associated with changes in fatigue. The tri-axial accelerometer in this configuration may be suitable for monitoring fatigue during the performance of functional activities.","abstract_has_math":false,"creators":["Morgan, Kristin"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Peter Pidcoe","Gerald Miller","Paul Wetzel"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:08:35Z","subjects":["Biomedical Engineering and Bioengineering","Engineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/1924"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/1924","href":"https://scholarscompass.vcu.edu/etd/1924","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/JM0N-HQ78","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/JM0N-HQ78","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-2923","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Peter Pidcoe","Gerald Miller","Paul Wetzel"]},{"key":"dc:creator","label":"Author","values":["Morgan, Kristin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-08-05T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/JM0N-HQ78","https://scholarscompass.vcu.edu/etd/1924"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In 2004, the National Collegiate Athletic Association reported ankle sprain as the most frequent injury in soccer, basketball, and volleyball players. Further research found an increased likelihood with fatigue. Measuring fatigue during functional activities has been a longstanding problem. In this study, changes in ankle biomechanics were measured using a tri-axial accelerometer embedded in the shoe as subjects (n=12) performed a fatiguing activity. Data were collected from the accelerometer and from established devices that are considered the industry gold standard. Several kinetic and kinematic accelerometer derived variables were highly correlated with these standards (r2>0.90) and were associated with changes in fatigue. The tri-axial accelerometer in this configuration may be suitable for monitoring fatigue during the performance of functional activities."]},{"key":"dc:title","label":"Title","values":["THE USE OF A TRI-AXIAL ACCELEROMETER TO MEASURE CHANGES IN LOWER EXTREMITY FATIGUE DURING FUNCTIONAL ACTIVITY"]}]}],"canonical_facts":{"dc:contributor":["Peter Pidcoe","Gerald Miller","Paul Wetzel"],"dc:creator":["Morgan, Kristin"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:date.created":["2009-08-05T07:00:00Z"],"dc:description.abstract":["In 2004, the National Collegiate Athletic Association reported ankle sprain as the most frequent injury in soccer, basketball, and volleyball players. Further research found an increased likelihood with fatigue. Measuring fatigue during functional activities has been a longstanding problem. In this study, changes in ankle biomechanics were measured using a tri-axial accelerometer embedded in the shoe as subjects (n=12) performed a fatiguing activity. Data were collected from the accelerometer and from established devices that are considered the industry gold standard. Several kinetic and kinematic accelerometer derived variables were highly correlated with these standards (r2>0.90) and were associated with changes in fatigue. The tri-axial accelerometer in this configuration may be suitable for monitoring fatigue during the performance of functional activities."],"dc:identifier":["https://doi.org/10.25772/JM0N-HQ78","https://scholarscompass.vcu.edu/etd/1924"],"dc:rights":["© The Author"],"dc:subject":["Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["THE USE OF A TRI-AXIAL ACCELEROMETER TO MEASURE CHANGES IN LOWER EXTREMITY FATIGUE DURING FUNCTIONAL ACTIVITY"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:08:35Z"}