{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-2994"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-2994","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"MECHANICAL STRUCTURES RESISTING ANTERIOR INSTABILITY IN A COMPUTATIONAL GLENOHUMERAL JOINT MODEL","abstract":"The glenohumeral joint is the most dislocated joint in the body due to the lack of bony constraints and dependence on soft tissue, primarily muscles and ligaments, to stabilize the joint. The goal of this study was to develop a computational model of the glenohumeral joint whereby joint behavior was dictated by articular contact, ligamentous constraints, muscle loading, and external perturbations. Validation of this computational model was achieved by comparing predicted results from the model to the results of a cadaveric experiment in which the relative contribution of muscles and ligaments to anterior joint stability was examined. The results showed the subscapularis to be critical to stabilization in both neutral and external rotations, the biceps stabilized the joint in neutral but not external rotation, and the inferior glenohumeral ligament resisted anterior displacement only in external rotation. Knowledge gained from this model could assist in pre-operative planning or the design of orthopedic implants. Use of this model as a companion to cadaveric testing could save valuable time and resources.","abstract_html":"The glenohumeral joint is the most dislocated joint in the body due to the lack of bony constraints and dependence on soft tissue, primarily muscles and ligaments, to stabilize the joint. The goal of this study was to develop a computational model of the glenohumeral joint whereby joint behavior was dictated by articular contact, ligamentous constraints, muscle loading, and external perturbations. Validation of this computational model was achieved by comparing predicted results from the model to the results of a cadaveric experiment in which the relative contribution of muscles and ligaments to anterior joint stability was examined. The results showed the subscapularis to be critical to stabilization in both neutral and external rotations, the biceps stabilized the joint in neutral but not external rotation, and the inferior glenohumeral ligament resisted anterior displacement only in external rotation. Knowledge gained from this model could assist in pre-operative planning or the design of orthopedic implants. Use of this model as a companion to cadaveric testing could save valuable time and resources.","abstract_has_math":false,"creators":["Elmore, Kevin"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Jennifer Wayne"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:08:35Z","subjects":["Musculoskeletal","Computational Model","Shoulder","Subluxation","Dislocation","Validation","Ligaments","SolidWorks","CosmosMOTION","Rigid Body Dynamics","Computed Tomography","Glenohumeral","Biomedical Engineering and Bioengineering","Engineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/1995"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/1995","href":"https://scholarscompass.vcu.edu/etd/1995","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/S8VR-TK68","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/S8VR-TK68","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-2994","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jennifer Wayne"]},{"key":"dc:creator","label":"Author","values":["Elmore, Kevin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-11-24T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Musculoskeletal","Computational Model","Shoulder","Subluxation","Dislocation","Validation","Ligaments","SolidWorks","CosmosMOTION","Rigid Body Dynamics","Computed Tomography","Glenohumeral","Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/S8VR-TK68","https://scholarscompass.vcu.edu/etd/1995"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The glenohumeral joint is the most dislocated joint in the body due to the lack of bony constraints and dependence on soft tissue, primarily muscles and ligaments, to stabilize the joint. The goal of this study was to develop a computational model of the glenohumeral joint whereby joint behavior was dictated by articular contact, ligamentous constraints, muscle loading, and external perturbations. Validation of this computational model was achieved by comparing predicted results from the model to the results of a cadaveric experiment in which the relative contribution of muscles and ligaments to anterior joint stability was examined. The results showed the subscapularis to be critical to stabilization in both neutral and external rotations, the biceps stabilized the joint in neutral but not external rotation, and the inferior glenohumeral ligament resisted anterior displacement only in external rotation. Knowledge gained from this model could assist in pre-operative planning or the design of orthopedic implants. Use of this model as a companion to cadaveric testing could save valuable time and resources."]},{"key":"dc:title","label":"Title","values":["MECHANICAL STRUCTURES RESISTING ANTERIOR INSTABILITY IN A COMPUTATIONAL GLENOHUMERAL JOINT MODEL"]}]}],"canonical_facts":{"dc:contributor":["Jennifer Wayne"],"dc:creator":["Elmore, Kevin"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:date.created":["2009-11-24T08:00:00Z"],"dc:description.abstract":["The glenohumeral joint is the most dislocated joint in the body due to the lack of bony constraints and dependence on soft tissue, primarily muscles and ligaments, to stabilize the joint. The goal of this study was to develop a computational model of the glenohumeral joint whereby joint behavior was dictated by articular contact, ligamentous constraints, muscle loading, and external perturbations. Validation of this computational model was achieved by comparing predicted results from the model to the results of a cadaveric experiment in which the relative contribution of muscles and ligaments to anterior joint stability was examined. The results showed the subscapularis to be critical to stabilization in both neutral and external rotations, the biceps stabilized the joint in neutral but not external rotation, and the inferior glenohumeral ligament resisted anterior displacement only in external rotation. Knowledge gained from this model could assist in pre-operative planning or the design of orthopedic implants. Use of this model as a companion to cadaveric testing could save valuable time and resources."],"dc:identifier":["https://doi.org/10.25772/S8VR-TK68","https://scholarscompass.vcu.edu/etd/1995"],"dc:rights":["© The Author"],"dc:subject":["Musculoskeletal","Computational Model","Shoulder","Subluxation","Dislocation","Validation","Ligaments","SolidWorks","CosmosMOTION","Rigid Body Dynamics","Computed Tomography","Glenohumeral","Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["MECHANICAL STRUCTURES RESISTING ANTERIOR INSTABILITY IN A COMPUTATIONAL GLENOHUMERAL JOINT MODEL"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:08:35Z"}