{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-2995"},"canonical_url":"https://search.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-2995","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Automated Methods for Fiber Diameter Measurement of Fibrous Scaffolds","abstract":"The purpose of this work was to develop an automated method of measuring fiber diameters of electrospun scaffolds from scanning electron microscopy images of these scaffolds. Several automated methods were developed and evaluated by comparison to known values and data obtained via the standard manual method. Simulated images with known diameters were used as test images to evaluate the accuracy of each measurement technique. Eight scanning electron microscopy images were also used for the evaluation of the automated methods compared to the standard manual method. All diameter measurements were made in pixels. Five new automated methods coded in MATLAB were developed. The five methods varied the approach of identifying edges of fibers as well as assigning edges to single fibers and calculating the distance between edges assigned to the same fiber. One-way analysis of variance and the Tukey-Kramer tests were performed for comparison of all methods per image. The Custom Canny Slopes automated method was shown to accurately approximate the mean diameters in ten simulated images as well as microscopy image of real scaffolds (p<0.05).","abstract_html":"The purpose of this work was to develop an automated method of measuring fiber diameters of electrospun scaffolds from scanning electron microscopy images of these scaffolds. Several automated methods were developed and evaluated by comparison to known values and data obtained via the standard manual method. Simulated images with known diameters were used as test images to evaluate the accuracy of each measurement technique. Eight scanning electron microscopy images were also used for the evaluation of the automated methods compared to the standard manual method. All diameter measurements were made in pixels. Five new automated methods coded in MATLAB were developed. The five methods varied the approach of identifying edges of fibers as well as assigning edges to single fibers and calculating the distance between edges assigned to the same fiber. One-way analysis of variance and the Tukey-Kramer tests were performed for comparison of all methods per image. The Custom Canny Slopes automated method was shown to accurately approximate the mean diameters in ten simulated images as well as microscopy image of real scaffolds (p&lt;0.05).","abstract_has_math":false,"creators":["Bulysheva, Anna"],"institution":null,"degree_name":"Master of Science","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Gary Bowlin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:08:42Z","subjects":["Automated Method","Electrospinning","Fiber Diameter","Tissue Engineering","Biomedical Engineering and Bioengineering","Engineering"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/1996"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/1996","href":"https://scholarscompass.vcu.edu/etd/1996","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25772/HY6K-SJ78","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25772/HY6K-SJ78","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarscompass.vcu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarscompass.vcu.edu%3Aetd-2995","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gary Bowlin"]},{"key":"dc:creator","label":"Author","values":["Bulysheva, Anna"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-12-07T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Automated Method","Electrospinning","Fiber Diameter","Tissue Engineering","Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/HY6K-SJ78","https://scholarscompass.vcu.edu/etd/1996"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this work was to develop an automated method of measuring fiber diameters of electrospun scaffolds from scanning electron microscopy images of these scaffolds. Several automated methods were developed and evaluated by comparison to known values and data obtained via the standard manual method. Simulated images with known diameters were used as test images to evaluate the accuracy of each measurement technique. Eight scanning electron microscopy images were also used for the evaluation of the automated methods compared to the standard manual method. All diameter measurements were made in pixels. Five new automated methods coded in MATLAB were developed. The five methods varied the approach of identifying edges of fibers as well as assigning edges to single fibers and calculating the distance between edges assigned to the same fiber. One-way analysis of variance and the Tukey-Kramer tests were performed for comparison of all methods per image. The Custom Canny Slopes automated method was shown to accurately approximate the mean diameters in ten simulated images as well as microscopy image of real scaffolds (p<0.05)."]},{"key":"dc:title","label":"Title","values":["Automated Methods for Fiber Diameter Measurement of Fibrous Scaffolds"]}]}],"canonical_facts":{"dc:contributor":["Gary Bowlin"],"dc:creator":["Bulysheva, Anna"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:date.created":["2009-12-07T08:00:00Z"],"dc:description.abstract":["The purpose of this work was to develop an automated method of measuring fiber diameters of electrospun scaffolds from scanning electron microscopy images of these scaffolds. Several automated methods were developed and evaluated by comparison to known values and data obtained via the standard manual method. Simulated images with known diameters were used as test images to evaluate the accuracy of each measurement technique. Eight scanning electron microscopy images were also used for the evaluation of the automated methods compared to the standard manual method. All diameter measurements were made in pixels. Five new automated methods coded in MATLAB were developed. The five methods varied the approach of identifying edges of fibers as well as assigning edges to single fibers and calculating the distance between edges assigned to the same fiber. One-way analysis of variance and the Tukey-Kramer tests were performed for comparison of all methods per image. The Custom Canny Slopes automated method was shown to accurately approximate the mean diameters in ten simulated images as well as microscopy image of real scaffolds (p<0.05)."],"dc:identifier":["https://doi.org/10.25772/HY6K-SJ78","https://scholarscompass.vcu.edu/etd/1996"],"dc:rights":["© The Author"],"dc:subject":["Automated Method","Electrospinning","Fiber Diameter","Tissue Engineering","Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["Automated Methods for Fiber Diameter Measurement of Fibrous Scaffolds"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-11-19T09:08:42Z"}